background image

 

 

 

 

4. Before operation 

 
 
Before using the machine it is essential to inspect the machine. 
It is not permitted to use the machine if the machine safety is not according the checkpoints below. 

 

Checkpoints of electrical safety 

 

Use only extension cables for extending the main cable that are sized and marked in accordance with 
the overall power consumption of the machine. 

 

Electrical cables must be rolled entirely off of the reels. 

 

Any damage to electric cables is not permitted 

 

Use an electrical power supply connection with earth connection. 

 

The main switch of the machine should be put to ‘Off’ before connecting to the power supply. 

 
 
 
 

5. Operation 

 
 
 
 
 
 
 
 
 

 

Starting / stopping the machine 

 

Connect the dust hose to the machine. 

 

Connect the dust collector to the power supply. 

 

Switch on the main switch. 

 

Switch on first the compressor motor. 

 

Secondly switch on the fan motor.  

 

Carry out this actions in opposite sequence to stop the machine. 

 

Work with the machine 

 

Regular check the contents of the dust-bin.  

 

Regular open the drain valve to remove water from the air tank. 

 

Interrupting work 

 

When temporarily interrupting the work (1/2 hour – 1 hour), turn off the fan unit only. Pulse cleaning 
of the filter system will continue and will increase the life-time of the filter cartridges. 

 

During a longer stand still of the dust collector, first switch off the fan unit. Let the pulse cleaning cycle 
run for +/- 5 minutes. Switch off the compressor unit and Main-switch. 

 

Disconnect the power-supply cable. 

 

Prevent unauthorized persons from getting access to the dust collector or take measurements to 
prevent unauthorized working with the equipment. 

1  Compressor ON/OFF 

2  Fan motor ON/OFF 

3  Emergency shut down 

4  Power socket 

5  Power ON/OFF – main switch 

Содержание BDC-99

Страница 1: ...OPERATING MANUAL BDC 99 VERSION 1 2 www blastrac com 1 800 256 3440...

Страница 2: ...equirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model Blastrac BDC 99 Serial number xxx...

Страница 3: ...afety precautions with regard to transport Safety regulations with regard to maintenance 4 Before operation 08 Checkpoints of power supply 5 Operation 08 Starting stopping the machine Work with the ma...

Страница 4: ...AA Class Designation L Low risk for separating dust with an exposure limit value of over 1 mg m3 depending on the volume occupied M BDC 99 Medium risk for separating dust with an exposure limit value...

Страница 5: ...act plate 5 Manometer shows the pressure of the air tank The pulse to clean the filters must be given at 5 5 5 bar 6 Drain valve Open regular to remove water from the air tank 7 Pressure valve must be...

Страница 6: ...e hazardous zone take precautions to prevent dust from escaping Safety precautions with regard to maintenance To allow the user to carry out maintenance operations the dust collector must be disassemb...

Страница 7: ...onnection do not change this and use always earthed cables with an earthed plug Connect the main power supply cable to an installation with an earth leakage circuit breaker Inspect and test the electr...

Страница 8: ...Switch on the main switch Switch on first the compressor motor Secondly switch on the fan motor Carry out this actions in opposite sequence to stop the machine Work with the machine Regular check the...

Страница 9: ...ieved during the corresponding period the period can be extended However a full overhaul must be carried out at least once a year Due to different working conditions it can t be foreseen how frequentl...

Страница 10: ...n the system is 5 5 5 bar The safety valve mounted on the compressor is activated at approximately 10 bar This provision is to ensure that when there is a defect in the Control valve the pressure in t...

Страница 11: ...k by the use of high class hepa filter Applied by us filters have high filtration efficiency starting from just 99 95 7 2 Difference vacuum gauge A vacuum gauge measures the difference between the und...

Страница 12: ...4 x 16mm2 15m 4 x 16mm2 15m Available plug connections 5 pole 63 Ampere 5 pole 63 Ampere Air flow with 20m hose 6 and medium shot blaster 1410m3 hr Air flow without hose 2654m3 hr Vacuum 66 mbar Dust...

Страница 13: ...noted on shipping receipt Hand Tool Products Blastrac warrants its BLASTRAC Hand Tool Products including hand grinders and accessories against defects in material and workmanship under normal and prop...

Страница 14: ...otors batteries tires and all other parts See component manufacture warranty 7 Blastrac reserves the right to make product changes or improvements without prior notice and without undertaking any obli...

Страница 15: ...Warranty Registration IMPORTANT To ensure that your Blastrac machine is covered under warranty please provide the information recorded here by registering online at blastrac com or complete this page...

Страница 16: ...Blastrac 13201 North Santa Fe Avenue Oklahoma City OK 73114 800 256 3440 Fax 866 485 1046 www blastrac com...

Отзывы: