background image

User Manual & Datasheet 

 

BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx 

14 

HDC 6012 

 

Network Information Table: 

Anyway the NIT should be re-generated for the DVB-C Tuners in your network by: 

 

Select the output frequencies and values for the QAM channels: 

high bandwidth can be reached by 

i.e.:  

-

 

256 QAM, Srate 6950, low FEC: 

 

you can add all other channels from your network here to generate a common NIT for all of them. 

 

Of course you should be experienced with the DVB-MPEG2 PSI/SI settings for the NIT. 
The original NIT from SAT is not valid for CATV and shouldn't be passed to the QAM's. 

Содержание HDC 6012

Страница 1: ...Web management Updates via web DiSEqC 1 0 LNB control for up to 4 satellite positions Dual power supply optional The BLANKOM HDC 6012 is a high performance and cost effective QAM Transmodulator It has...

Страница 2: ...Streams 10 Network Information Table 14 Adjusting RF QAM output 15 BISS decryption 18 Conditional Access encryption 20 Multiplexer 20 Network Settings 24 Configuration Backup Restore 24 Firmware upgra...

Страница 3: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 3 HDC 6012...

Страница 4: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 4 HDC 6012 Application Example...

Страница 5: ...gth 65 25dBm Supports QPSK 8PSK supports DiSEqC 1 0 LNB control for up to 4 satellite positions BISS descrambling capable Multiplexing 4 multiplexers Maximum PID remapping 128per input channel PID rem...

Страница 6: ...dress is 192 168 0 136 We recommend to use the latest Firefox Browser User password is per default admin admin and you end up in the Status window Setting up NTP Server for i e Europe Usually the unit...

Страница 7: ...cessary for the first time setup of this transmodulator So first chose your region than try to get some NTP Server addresses from the internet like Or use Setting up Tuner Inputs Of course L Band as w...

Страница 8: ...C 6012_Manual_EN RR 06 2021_V1 5 docx 8 HDC 6012 Enter the values 10741 25 as frequency Horizontal 18V ON Symbolrate 22000 SAT pos 1 depending on your Multiswitch LOW Band 22KHz off FEC will be detect...

Страница 9: ...nput must use the same SAT position polarisation band as the first one by avoiding different polarisations H V and low High Band must be equal Setting up a second transponder from SAT POS 2 here Hotbi...

Страница 10: ...witched on Finally we have all tuners configured and running Setting up incoming IP Streams We have some streams connected to the same switch from another source as MPTS and some as SPTS so we need to...

Страница 11: ...n see all tuner inputs even with bitrates received but no content yet First we have already added a SPTS from 239 42 22 1 Multicast address as UDP with port number 1234 So we add an MPTS coming as Mul...

Страница 12: ...6012 Now we need to parse each tuner and IP stream content to the machine or parse step by step each marked Tuner1 12 and IP streams Parse select all SPTS already assigns the SPTS to the output Here...

Страница 13: ...Service was scrambled somehow decrypted i e coming as MPTS or SPTS and containing still CA Flags and maybe EMM ECM PIDs which are filktered out by this CA Filter becasue the output mux should not reco...

Страница 14: ...elect the output frequencies and values for the QAM channels high bandwidth can be reached by i e 256 QAM Srate 6950 low FEC you can add all other channels from your network here to generate a common...

Страница 15: ...rt is now the right time So we adjust the own DVB C RF channels here Because the channels are adjacent 4x 8 MHz and we don t use the american Annex B standard ITU we get the overall settings as The SP...

Страница 16: ...012 PID remapping is recommended to avoid collisions To avoid an Overflow you should always consider an overhead of 10 15 because the peaks would disturb all services in the bouquet which isn t that n...

Страница 17: ...2021_V1 5 docx 17 HDC 6012 So better to get rid of one of them Thats not enough so we delete a 2nd one Thats much better To get the full information just click on a service And you can manipulate eve...

Страница 18: ...atasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 18 HDC 6012 BISS decryption You can descramble a selected service by a BISS key which you need to configure before in the BISS section Than sel...

Страница 19: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 19 HDC 6012 It will be shown now and selectable in the Programm Information...

Страница 20: ...012 Conditional Access encryption The already configured output multiplexes can be simul encrypted by up to 4 different CA Systems The configuration is nearly self explaining Multiplexer Back to the M...

Страница 21: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 21 HDC 6012 with the PID Bypass you can pass individual PIDs from the Inputs to the outputs...

Страница 22: ...he content and assign it to the Output with CA Filter and PID remapping The CA components are filtered out and the PIDs are remapped After finally all QAM Outputs are configured maybe write a new NIT...

Страница 23: ...atasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 23 HDC 6012 Each of them can be configured as scrambled if CAS is setup or even as unscrambled you can set it as VBR null paket filter enables...

Страница 24: ...06 2021_V1 5 docx 24 HDC 6012 Network Settings Scrambler and NMS are on the same Ethernet RJ45 port with 100BaseT while the DATA port has GbE NMS and scrambler communication port IP addresses can be c...

Страница 25: ...BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 25 HDC 6012 Save will internally save your config but we recommend to backup the file to your computer Restoring works vice versa Firmware upgrade is n...

Страница 26: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 26 HDC 6012...

Страница 27: ...6 2021_V1 5 docx 27 HDC 6012 Logs should be sent to us in case of support issues Please note Remultiplexing would destroy EPG data from the original source This cost effective Receiver multiplexer scr...

Страница 28: ...this publication and make changes in its content from time to time whereby it shall not be obligatory for IRENIS GmbH to provide notification of such revision or change IRENIS GmbH provides this manua...

Страница 29: ...administrative scope sessions using administratively scoped IP multicast The multicast address to be used for announcements is the highest multicast address in the relevant administrative scope zone...

Страница 30: ...230 237 233 50 231 25 236 75 40 630 638 634 00 631 25 636 75 S 12 237 244 240 50 238 25 243 75 41 638 646 642 00 639 25 644 75 S 13 244 251 247 50 245 25 250 75 42 646 654 650 00 647 25 652 75 S 14 2...

Страница 31: ...6 31 5 3E 04 17 77 31 75 7 08 6 7E 04 18 78 30 75 7 94 8 4E 04 19 79 29 75 8 91 1 1E 03 20 80 28 75 10 00 1 3E 03 21 81 27 75 11 22 1 7E 03 22 82 26 75 12 59 2 1E 03 23 83 25 75 14 13 2 7E 03 24 84 24...

Страница 32: ...841 49 109 0 25 281 84 1 059 50 110 1 25 316 23 1 333 51 111 2 25 354 81 1 679 52 112 3 25 398 11 2 113 53 113 4 25 446 68 2 660 54 114 5 25 501 19 3 349 55 115 6 25 562 34 4 216 56 116 7 25 630 96 5...

Страница 33: ...timmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce...

Страница 34: ...be damaged or crushed by any objects Furthermore ensure that cables are not laid in the immediate vicinity of sources of heat e g radiators other electrical devices fireplaces etc Risk of fire risk o...

Страница 35: ...and operated when the mains adaptor cover is installed This also applies when you clean the device or work on the connections Danger Repairs on the device may only be carried out by a specialist see...

Страница 36: ...egenst nde besch digt oder gequetscht werden Es ist dar ber hinaus unbedingt darauf zu achten da Kabel nicht in die direkte N he von W rmequellen verlegt werden z B Heizk rper andere Elektroger te Kam...

Страница 37: ...mit montierter Netzteilabdeckung an Spannung angeschlossen und betrieben werden Dies gilt auch wenn Sie das Ger t reinigen oder an den Anschl ssen arbeiten Gefahr Reparaturen am Ger t sind ausschlie...

Страница 38: ...p of the power supply unit Das Netzger t darf nicht Tropf oder Spritzwasser ausgesetzt sein The power supply unit must not be exposed to dripping or splashing water Der Netzstecker muss ohne Schwierig...

Страница 39: ...tact IRENIS GmbH Hauptstr 29 31171 Nordstemmen Germany Phone 49 5069 4809781 IRENIS technical hotline VoIP 49 5069 4399 860 or 8601 Managing Director Dipl Ing Murad nol Commercial Register HRB 206370...

Отзывы: