AMA 299

Part N

o

: 9859.8x

QAM Modulator

ASI-TS 

 DVB-C/ ITU-T J.83 Annex B, C

A

LINE

1. Safety and operating instructions

 

When assembling, starting-up and adjusting the modules, it is necessary to consider the system specific references in 
the manual instruction.

 

The modules may only be installed and started up by authorized technical personne.

 

When assembling the modules into the receiving points, the adherence of the EMC regulations is to be secured.

 

The assembly and wiring have to be done without voltage.

 

With all work the defaults of the DIN EN 50083 have to be considered. Especially the safety relevant execution of the 

 

DIN EN 60728-11 [3] is necessary.

 

   

The devices come under protection classification I. It is absolutely necessary, therefore, to insert the mains plug into a

 

   

socket with protective contact.

2. Device variants

AMA 299   

9859.81  ASI - TS 

 DVB-C / ITU-T J.83 Annex B, C

 

 

9859.82  ASI - TS 

 IFI 

→ 

DVB-C / ITU-T J.83 Annex B, C

3. General

The QAM Modulator AMA 299 is a module of the head end system A-LINE which is conceived as a complete system for big and
middle-sized networks.The module converts one digital transponder into the digital cable standard DVB-C, ITU-T J.83  Annex B or C. 
The signal will be transcoded from the ASI transport stream into cable TV channels.

The status of the assembly will displayed with LED‘s (see section 5.2 ”Meaning of the LED signals”).

4. Functional description

The data stream which results from the ASI input is passed to a FIFO. All services of the resulting transport stream which shall be
processed into the QAM modulator will be choosen by controling software of the module. The SI and PSI tables affected (i.e. the PAT, 
PMT, SDT, EIT, NIT) are automatically corrected. The changed SI an PSI tables are fed into the QAM modulator and an IF signal is ge-
nerated at the output channel. There is a free choise of frequency in the output channel from 45 to 862 MHz. On the output side, the 
modulator does not leak to adjacent channels. For level error reporting a reference level is generated internally and is compared with 
current value permanently. After each programming of the level and/or frequency values an automatic measurement of the reference 
level takes place. The integrated management unit consists of the data interface for PC/ LAN/ WAN (IP/ Ethernet interface / RJ 45). 
The management of the module can be done via PC/Laptop (see programming).
The IP address of each device can be edited and adjusted to the respective LAN.

WEEE-Reg.-Nr. DE 50389067

Содержание 9859.81

Страница 1: ...Professional Headend Solutions Device manual AMA 299 Part No 9859 8x QAM Modulator ASI TS DVB C ITU T J 83 Annex B C...

Страница 2: ...eel 4 5 4 Rear view 5 5 5 9 pin D SUB connector configuration alarm contact 5 6 Programming by web server 6 6 1 Network connection to computer 6 6 2 Device status 7 6 3 Standard settings 7 6 4 Extende...

Страница 3: ...cable standard DVB C ITU T J 83 Annex B or C The signal will be transcoded from the ASI transport stream into cable TV channels The status of the assembly will displayed with LED s see section 5 2 Me...

Страница 4: ...tivating the BACK Pad you leave the current mode menu selection without any acceptance of settings or adjustments The cursor jumps one menu level higher Pressing of the tuning wheel is equivalent to t...

Страница 5: ...vice variant 9859 82 available 5 5 9 pin D SUB connector configuration alarm contact ALARM LAN WAN Power Factory set RF out ASI IN ASI OUT IF IN IF OUT Alarm active Pin 8 and Pin 9 are closed Pin 8 an...

Страница 6: ...ask 255 255 255 0 IP address 192 168 2 XXX Don t be use the same combination lock for XXX like the IP address of the AMA 299 The IP address of the AMA 299 is entered onto the browser interface When th...

Страница 7: ...rt stream TS Manager QAM Modul status of TS manager QAM modulator Up Converter status of up converter RF Amplifier status of RF amplifier Date acc adjustments in 6 3 Time acc adjustments in 6 3 12 24...

Страница 8: ...65535 Operator ID selectable 0 65535 Transport stream Change ID s activate or deactivate TS ID selectable 0 65535 Network ID selectable 0 65535 6 5 NIT table Choose language german english NIT table...

Страница 9: ...d in data stream as other Program selection Operating mode program filter pass or drop of the market programs Reserve selection all not marked programs are choosen or vice versa Select all all program...

Страница 10: ...s IP Address 192 168 2 80 Subnet mask 255 255 255 0 Default gateway 192 168 2 1 MAC Address display of MAC address Login settings Administrator login User name admin Password password User login User...

Страница 11: ...of program memory in the FPGA 09 FPGA PID memory WARNING overflow of PID memory in the FPGA 10 FPGA Directory full WARNING overflow of directory in the FPGA 11 FPGA FAT memory full WARNING overflow of...

Страница 12: ...al Back Table processing NIT Processing Off Distribution Off Network name BLANKOM Network ID 00000 Back RF output Settings Frequency kHz 306000 Level dBm 14 Back QAM modulator Settings Symbol rate 690...

Страница 13: ...t input level 14 dBm 95 dB V Connector 2x BNC socket 75 IF decoupling 80 dB RF output Output frequency range 45 862 MHz Tuning step 10 kHz 25 kHz Max output level 14 dBm 123 dB V Level adjustment rang...

Страница 14: ...equency SDT Service Description Table SI Service Information SNMP Simple Network Management Protocol TS Transport Stream 12 Bibliography 1 EN 50083 9 Cabled distribution systems for television sound a...

Страница 15: ...clares the conformity of the product group Product name QAM Modulator Type AMA 299 Product number 9859 8x according to the following regulations EN 50083 2 EN 60728 11 as far as relevant and additiona...

Отзывы: