11
CONVERSIONS
8) PROPANE GAS TO NATURAL GAS
CONVERSION PROCEDURE
Appliance models: Gas stainless steel hotplate
models:
PI5V 5 Burners
1.
Remove each burner cap and burner skirt.
2.
Remove the Propane Gas main injector with a 7
mm/VF tube spanner and replace with the
appropriate size Natural Gas injector for each
burner. The following injector sizes are required for
Natural Gas:
Burner
Main injector
Wok
94 mm
Rapid
91 mm
Semi Rapid
70 mm
Semi Rapid 70 mm
Auxiliary
53 mm
3.
Shut off gas supply to the appliance.
4.
Disconnect gas inlet pipe from the Propane Gas
test point inlet fitting.
5.
Remove the Propane Gas test point inlet fitting
from the appliance.
6.
Fit the Natural Gas Regulator supplied in the
conversion kit.
7.
Connect the gas supply to the Regulator.
8.
Check for gas leaks. Do not use a naked flame
to check for gas leaks.
9.
Adjust the gas pressure to 1.00 kPa.
10.
Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector anti-clockwise.
Test the appliance on both high and low flame for
each burner. If the burner fails to remain alight or
the flame is not stable on the simmer setting, adjust
the by-pass screw, until flame is stable.
11.
If not already removed, remove the “Only for
use with Propane Gas” label adhered to the bottom
panel near the gas connection.
9)
NATURAL
GAS
TO
PROPANE GAS CONVERSION PROCEDURE
Appliance models: Gas stainless steel hotplate
models:
PI5V 5 Burners
1.
Remove each burner cap and burner skirt.
2.
Remove the Natural Gas main injector with a 7
mm/VF tube spanner and replace with the
appropriate size Propane Gas main injector for each
burner. The following injector sizes are required for
Propane Gas:
Burner
Main injector
Wok
176 mm
Rapid
155 mm
Semi Rapid
120 mm
Semi Rapid 120 mm
Auxiliary
90 mm
3.
Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector fully clockwise.
4.
Shut off gas supply to the appliance.
5.
Disconnect gas inlet pipe from the Natural Gas
Regulator.
6.
Remove the Natural Gas Regulator from the
appliance.
7.
Fit the Propane Gas test point inlet fitting
supplied in the conversion kit.
8.
Connect the gas supply to the inlet fitting.
9.
Check for gas leaks. Do not use a naked flame
to check for gas leaks.
10.
Adjust the gas pressure to 2.75 kPa.
11.
Test the appliance on both high and low flame
for each burner and check the gas pressure. If the
burner fails to remain alight or the flame is not
stable on the simmer setting, adjust the by-pass
screw, until flame is stable.
12.
If not already removed, remove the “Only for
use with Natural Gas” label adhered to the bottom
panel near the gas connection.
Содержание PI5V
Страница 7: ...7 INSTALLATION...
Страница 8: ...8 INSTALLATION FILOTOP HOT PLATE INSTALLATION 65 3 3 FIG 10...