background image

HG-CF-1129 Rev. F - 19.10.09 

Page 7 

TROUBLE SHOOTING GUIDE 

NOTE :- Check all solutions before dismantling the pump. 

PROBLEM

 

CAUSE

 

SOLUTION

 

Pump will not start 

Air valve assembly malfunction/Seizure 
 
Obstructed fluid line. 
Obstructed diaphragm chamber. 
Diaphragm failure causing fluid & excessive air to be 
expelled through the exhaust. 
Diaphragm seal failure. 
Air valve system malfunction. 
Air connected to exhaust. 

Check carrier for freedom of movement. - 
Clean, oil & replace. 
Clean line or increase line size. 
Remove obstruction. 
Replace diaphragm. 
 
Replace shaft seals. 
Check all seals in valve chest assembly. 
Re-connect to air inlet. 

Erratic flow 

Diaphragm failure on one side. 
Valve ball not seating. 
Suction leakage. 
Diaphragm failure causing fluid & excessive air to be 
expelled through the exhaust. 
Diaphragm seal failure. 
Air valve system malfunction. 

Replace diaphragm. 
Check and remove obstruction. 
Check and correct. 
Replace diaphragm. 
 
Replace shaft seals. 
Check all seals in valve chest assembly. 

Pump strokes but will not 
discharge 

Excessive suction lift. 
Suction line leakage. 
Valve ball not seating correctly or damaged. 
Suction line or strainer clogged. 
Diaphragm failure. 

Shorten suction line. 
Check and correct. 
Check and remove obstruction / replace. 
Clear. 
Replace diaphragm. 

Fluid discharged from air 
exhaust 

Diaphragm Failure. 
Loose frontplate. 

Replace diaphragm. 
Re-Torque to manual specifications. 

Intermittent stroke rate 

Over lubrication 
 
 
 
Diaphragm shaft seal failure. 
Air valve system malfunction. 
Valve ball not seating / partially obstructed. 

Shut-down pump. Remove air connection 
into pump & introduce a small quantity of de-
greasing agent into air valve and replace 
line. Run pump until clear. 
Replace seals. 
Check all seals in valve chest assembly. 
Clear obstruction. 

The Atex approved units are supplied with a natural earth ground 
cable. This cable is 2 meters in length and permanently connected 
through a nut and bolt at the inner cover casting. The other end is free 
to connect to the nearest available suitable point to provide a natural 
earth ground. This must be done to reduce the risk of electro-static 
sparking.  

Grounding the pump :- 

 
Take action to prevent static sparking. Fire or 
explosion can result, especially when handling 
flammable liquids. The pump, piping, valves, 
containers or other miscellaneous equipment 
must be grounded. 

WARNING! 

ATEX Certified units :- X0601SS.. 

These models are certified to :- 

 
Non-electrical equipment for potentially explosive atmospheres : EN13463-1 : 2001, ‘c’ - Internal control of production. 

II 2 GD c 

ADDITIONAL PARTS FOR ATEX CAT. 2 PUMPS (see also page 10) 

REF 

No. 

PART 

NUMBER 

QTY 

38 

SA10289 

GROUNDING LEAD 

 

39 

SP467 

ATEX I/D TAG 

 

DESCRIPTION 

40 

SP472 

TIE-LOK TIE 

 

Содержание B06

Страница 1: ...TED DOUBLE DIAPHRAGM PUMP Table of Contents Service Maintenance Log Recycling 2 Dimensions 3 Performance Curve 3 Technical Data Temperature limitations 4 Explanation of Pump Nomenclature 4 Principle of Pump Operation 5 Installation guide 5 Important Warnings Safety Information 6 Troubleshooting 7 Grounding the Pump 7 Warranty 8 Service 8 Air Valve Overhaul 8 Wet side Overhaul 8 Exhaust Safety 9 Hi...

Страница 2: ...Contact Phone Fax No Contact Information RECYCLING Many components of BLAGDON air operated double diaphragm pumps are made of recyclable materials We encourage pump users to recycle worn out parts and pumps whenever possible after any hazardous pumped fluids are thoroughly flushed ...

Страница 3: ... CF 1129 Rev F 19 10 09 Page 3 GA Drawing Performance Curve General Assembly B06 FDA Metallic pump all dimensions 1mm B06 Metallic Pump Performance Curve performance based on water at ambient temperature ...

Страница 4: ... trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures 356o F 180o C 32o F 0o C 50o to 212o F 10o to 100o C LAMBERT ROAD ARMSTRONG WASHINGTON TYNE WEAR NE37 1QP ENGLAND TEL 0044 0 191 4177475 FAX 0044 0 191 4175435 Web Site www blagdonpump com E Mail sales blagdonpump com IMPORTANT This pump should be used in accordance with the requirements of the Health a...

Страница 5: ...configured as a 2 1 ratio model NOTE Pressure Regulator H should be installed where air supply could exceed 125 psi SAFETY Your BLAGDON PUMP is a high performance unit capable of achieving high outputs at high efficiencies However as is common with pneumatic equipment the pump efficiencies is reliant upon the air being clean dry and filtered Failure to comply with these requirements may lead to lo...

Страница 6: ...ase refer to the manufacturer for details IMPORTANT Important Warnings and Safety Information This pump is pressurized internally with air pressure during operation Always make certain that all bolting is in good condition and that all of the correct bolting is reinstalled during assembly End user must ensure correct fitting of Inlet Outlet connections Crossed threads or over tightening of connect...

Страница 7: ...ar Replace diaphragm Fluid discharged from air exhaust Diaphragm Failure Loose frontplate Replace diaphragm Re Torque to manual specifications Intermittent stroke rate Over lubrication Diaphragm shaft seal failure Air valve system malfunction Valve ball not seating partially obstructed Shut down pump Remove air connection into pump introduce a small quantity of de greasing agent into air valve and...

Страница 8: ...tically actuated valve systems Check the diaphragm shaft for excessive wear as this will result in premature seal failure Replace as required Lubricate all components and re assemble as detailed above in reverse order Ensure the correct position of all components detailed in all sectional assembly drawings WET SIDE OVERHAUL REPLACING BALL VALVES Remove discharge manifold from pump assembly togethe...

Страница 9: ...ing away In submerged conditions ensure exhaust is piped away above fluid level In all conditions ensure exhaust outlet is not expelling across a non conductive surface The exhaust must not be placed less than 100mm from any non conductive surface as this may generate a propagating brush discharge resulting in a possible ignition source In the event of diaphragm rupture pumped material may enter t...

Страница 10: ... 32 06 153 DIAPHRAGM SHAFT BUSH B 2 33 G264 O RING 2 34 SA10160 FRONTPLATE ASSY 2 35 06 147 DIAPHRAGM SUPPORT 2 36 06 009 BACKPLATE 2 37 06 141 DIAPHRAGM PTFE 2 REF No DESCRIPTION POLYESTER EPDM VITON QTY 23 DIAPHRAGM 06 010 06 070 06 060 2 ELASTOMER TABLE SANTOPRENE 06 147 REF No DESCRIPTION PTFE VITON STAINLESS STEEL QTY 20 VALVE BALL DISCHARGE 06 145 06 151 06 146 2 24 VALVE BALL SUCTION 06 108...

Страница 11: ...HG CF 1129 Rev F 19 10 09 Page 11 Sectional General Assembly B06 Metallic Pump Refer to page 10 Parts List table for item Ref Nos ...

Страница 12: ...29 Rev F 19 10 09 Page 12 BLAGDON PUMP A Unit of IDEX Corporation Lambert Road Armstrong Washington Tyne Wear NE37 1QP England Tel 44 0 191 4177475 Fax 44 0 191 4175435 Jeff Sill General Manager HG CF 223 REV 4 ...

Отзывы: