HG-CF-1129 Rev. F - 19.10.09 

Page 1 

 

B06 & X06

 

 

Metallic FDA Series 

04 Series 

 

This pump is Atex approved for use 

in potentially explosive atmospheres 

Group II category 2 

 
 

This pump is normally supplied with Tri-Clamp end connections 

See parts list for other options.

 

SERVICE & OPERATING MANUAL 

AIR OPERATED DOUBLE DIAPHRAGM PUMP 

Table of Contents 

 

Service / Maintenance Log, Recycling 

Dimensions 

Performance Curve 

Technical Data & Temperature limitations 

Explanation of Pump Nomenclature 

Principle of Pump Operation 

Installation guide 

Important Warnings & Safety Information 

Troubleshooting 

Grounding the Pump 

Warranty 

Service 

Air Valve Overhaul 

Wet-side Overhaul 

Exhaust Safety 

High Temperature Inst. 

Parts List 

10 

Assembly Drawing 

11 

Declaration of Conformity 

12 

II 2 GD c 

Содержание B06

Страница 1: ...TED DOUBLE DIAPHRAGM PUMP Table of Contents Service Maintenance Log Recycling 2 Dimensions 3 Performance Curve 3 Technical Data Temperature limitations 4 Explanation of Pump Nomenclature 4 Principle of Pump Operation 5 Installation guide 5 Important Warnings Safety Information 6 Troubleshooting 7 Grounding the Pump 7 Warranty 8 Service 8 Air Valve Overhaul 8 Wet side Overhaul 8 Exhaust Safety 9 Hi...

Страница 2: ...Contact Phone Fax No Contact Information RECYCLING Many components of BLAGDON air operated double diaphragm pumps are made of recyclable materials We encourage pump users to recycle worn out parts and pumps whenever possible after any hazardous pumped fluids are thoroughly flushed ...

Страница 3: ... CF 1129 Rev F 19 10 09 Page 3 GA Drawing Performance Curve General Assembly B06 FDA Metallic pump all dimensions 1mm B06 Metallic Pump Performance Curve performance based on water at ambient temperature ...

Страница 4: ... trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures 356o F 180o C 32o F 0o C 50o to 212o F 10o to 100o C LAMBERT ROAD ARMSTRONG WASHINGTON TYNE WEAR NE37 1QP ENGLAND TEL 0044 0 191 4177475 FAX 0044 0 191 4175435 Web Site www blagdonpump com E Mail sales blagdonpump com IMPORTANT This pump should be used in accordance with the requirements of the Health a...

Страница 5: ...configured as a 2 1 ratio model NOTE Pressure Regulator H should be installed where air supply could exceed 125 psi SAFETY Your BLAGDON PUMP is a high performance unit capable of achieving high outputs at high efficiencies However as is common with pneumatic equipment the pump efficiencies is reliant upon the air being clean dry and filtered Failure to comply with these requirements may lead to lo...

Страница 6: ...ase refer to the manufacturer for details IMPORTANT Important Warnings and Safety Information This pump is pressurized internally with air pressure during operation Always make certain that all bolting is in good condition and that all of the correct bolting is reinstalled during assembly End user must ensure correct fitting of Inlet Outlet connections Crossed threads or over tightening of connect...

Страница 7: ...ar Replace diaphragm Fluid discharged from air exhaust Diaphragm Failure Loose frontplate Replace diaphragm Re Torque to manual specifications Intermittent stroke rate Over lubrication Diaphragm shaft seal failure Air valve system malfunction Valve ball not seating partially obstructed Shut down pump Remove air connection into pump introduce a small quantity of de greasing agent into air valve and...

Страница 8: ...tically actuated valve systems Check the diaphragm shaft for excessive wear as this will result in premature seal failure Replace as required Lubricate all components and re assemble as detailed above in reverse order Ensure the correct position of all components detailed in all sectional assembly drawings WET SIDE OVERHAUL REPLACING BALL VALVES Remove discharge manifold from pump assembly togethe...

Страница 9: ...ing away In submerged conditions ensure exhaust is piped away above fluid level In all conditions ensure exhaust outlet is not expelling across a non conductive surface The exhaust must not be placed less than 100mm from any non conductive surface as this may generate a propagating brush discharge resulting in a possible ignition source In the event of diaphragm rupture pumped material may enter t...

Страница 10: ... 32 06 153 DIAPHRAGM SHAFT BUSH B 2 33 G264 O RING 2 34 SA10160 FRONTPLATE ASSY 2 35 06 147 DIAPHRAGM SUPPORT 2 36 06 009 BACKPLATE 2 37 06 141 DIAPHRAGM PTFE 2 REF No DESCRIPTION POLYESTER EPDM VITON QTY 23 DIAPHRAGM 06 010 06 070 06 060 2 ELASTOMER TABLE SANTOPRENE 06 147 REF No DESCRIPTION PTFE VITON STAINLESS STEEL QTY 20 VALVE BALL DISCHARGE 06 145 06 151 06 146 2 24 VALVE BALL SUCTION 06 108...