Alpha E-Tec S 20, 30 and 35 - Installation
Easy-Stat RF receiver and Digital or Mechanical Clock installation
1.
Remove the link between the red wires 3 and 4 and plug all wires
on to their corresponding numbers on the receiver or clock.
2. Locate the receiver or clock onto the two pins and using the
two screws provided fix into position.
3. Route the wires through the slot in the bottom righthand corner
of the housing.
4. Remove the round blanking panel from the cover panel and
re-fit the control panel cover in reverse order.
Fig. 5.18
9
8 7 6
5
4
3
2
1
27
20
15
10
5
0
-5
-10
-15
-20
External temperature (°C)
Max.
Min.
System
temperature
(°C)
Fig. 5.17
Open Therm type installation
Note:
Before purchasing / installing Open Therm type controls from an alternative manufacturer, it is the installers
responsibility to ensure they are compatible with the Alpha boiler.
Remove the control panel as described in Section 5.10, if it has not already been removed.
Refer to controls manufacturer's installation instructions for specific mounting / fitting guidance.
Route the BUS communication wires along the groove in the control panel to the terminal block connections 41 and 44 (the
wires can be connected either way round).
Ensure the link wire between terminals 1 and 2 remains in place.
Replace the control panel cover in reverse order.
Note:
Refer to parameter P7 (see Section 6.13) to select the correct parameter to allow the boiler to operate with alternative
control type '1'.
External Sensor – Weather compensation feature
The weather compensation sensor can only be used on an E-Tec S boiler when the Alpha Diverter Kit (part No.
6.5500048) is used, otherwise the DHW temperature will be affected
The E-Tec S boilers have a built in weather compensation feature which is automatically activated when the external
sensor is fitted – Part No 3.022383. When fitted the weather compensation sensor allows the boiler to control the maximum
primary flow temperature to the heating circuit according to the outside temperature, heating the property more effectively and
efficiently.
Operation
During a central heating on period the sensor monitors the external temperature and modulates the boiler heating output to
give the correct flow temperature to maintain the required room temperature. If the external temperature drops then the flow
temperature will increase, if the external temperature increases then the flow temperature will decrease. This reduces the
amount of wasted energy and reduces gas consumption.
When an external weather sensor is fitted the CH temperature control dial will no longer adjust the flow temperature in °C,
instead the display will show a scale of 1 to 9. Each number corresponds to a line on the graph in Fig. 5.18 e.g. line 6 will
give a flow temperature of 60°C when the external temperature is 10°C.
Note:
The temperature of the radiators will vary depending on the outside temperature; the required room temperature will
still be maintained by the room thermostat.
Comfort / Easy-Stat receiver
Blanking panel
Wires
Slot for wires
Содержание PREMIUM PLUS WHP030
Страница 2: ......
Страница 6: ...4 Blade 30 and 40 Water Heater Plus Manual July 2020 3 0 WATER HEATER SCHEMATIC LAYOUT...
Страница 7: ...Blade 30 and 40 Water Heater Plus Manual July 2020 5 3 1 SCHEMATIC LEGEND...
Страница 18: ...16 Blade 30 and 40 Water Heater Plus Manual July 2020 9 0 MAINTENANCE AND SERVICING CLEARANCES...
Страница 19: ...Blade 30 and 40 Water Heater Plus Manual July 2020 17 10 0 FRAME DETAILS...
Страница 20: ...18 Blade 30 and 40 Water Heater Plus Manual July 2020 11 0 INSTALLATION SCHEMATIC LAYOUT...
Страница 23: ...Blade 30 and 40 Water Heater Plus Manual July 2020 21 14 0 WIRING DIAGRAM...
Страница 31: ...Blade 30 and 40 Water Heater Plus Manual July 2020 29 Notes...
Страница 32: ...APPENDIX A ALPHA BOILER MANUAL...
Страница 91: ...59 Alpha E Tec S 20 30 and 35 Page intentionally Blank...
Страница 101: ...Blade 30 and 40 Water Heater Plus Manual July 2020 31 APPENDIX B DAB PUMP MANUAL...
Страница 115: ...ENGLISH 41 It is dangerous to touch the circulator DANGER OF SCALDING...
Страница 125: ...ENGLISH 51 18 PERFORMANCE CURVES EVOSTA2 40 70 XXX...
Страница 126: ...ENGLISH 52 EVOSTA2 80 XXX...
Страница 127: ...ENGLISH 53 EVOSTA3 40 XXX...
Страница 128: ...ENGLISH 54 EVOSTA3 60 XXX...
Страница 129: ...ENGLISH 55 EVOSTA3 80 XXX...