background image

English

21

Technical Specification

ID:60TVP

Power:

 60 Watts

Weight (kg):

 18

Dimensions (mm):

 584(W

 x 485(H

 x 250(D

Footswitch (not supplied):

 F

:

-4 latching footswitch, F

:

-10 footcontroller,  

MIDI footcontroller

ID:60TVP-H

Power:

 60 Watts

Weight (kg): 

10.8

Dimensions (mm):

 584(W

 x 236(H

 x 225(D

Footswitch (not supplied):

 F

:

-4 latching footswitch, F

:

-10 footcontroller,  

MIDI footcontroller

ID:260TVP

Power:

 2 x 60 Watts (

:

tereo

Weight (kg): 

24.2

Dimensions (mm):

 686(W

 x 510(H

 x 250(D

Footswitch (not supplied):

 F

:

-4 latching footswitch, F

:

-10 footcontroller,  

MIDI footcontroller

ID:100TVP

Power:

 100 Watts

Weight (kg): 

12.8

Dimensions (mm):

 686(W

 x 246(H

 x 225 (D

Footswitch (not supplied):

 F

:

-4 latching footswitch, F

:

-10 footcontroller,  

MIDI footcontroller

USB Audio 

:

tandard audio drivers are used to connect the amplifier to a PC or Mac, no specific 

drivers are required.

The amplifier will appear as an audio capture device within recording software.

The output of the audio over U

:)

 can be changed via the 

)

lackstar Insider software, 

and can be one of the following

!

„

:

peaker emulated stereo effected audio channels

„

2 x mono audio channels

   - 

3

eft – effected amplifier signal

 

 

- Right – unprocessed guitar signal 

„

Re-amping Mode

Re-amping

The amplifier can be switched into Re-amping Mode via 

)

lackstar Insider software. 

This is a non-storable setting and will be switched off either when the U

:)

 cable is 

removed, or when the amplifier power is switched off.

When activated, Re-amping Mode allows the amplifier to accept a pre-recorded, dry 
guitar signal via U

:)

 and return a fully processed audio signal. This return signal can 

then be captured using recording software on the connected PC or Mac.

Firmware Update

Firmware updates are initiated via 

)

lackstar Insider software. A new version of the 

)

lackstar Insider software will be released whenever an update is available. Each 

update will take approximately 60-120 seconds.

When the amplifier is connected (via U

:)

 to a version of the 

)

lackstar Insider 

software containing newer firmware, a message will be displayed, prompting you to 
install the latest files. Whilst updating, the amplifier controls will be unresponsive. The 
Tap 

3

ED flashes to indicate data activity during the update process.

The amplifier power should not be switched off during a firmware update. If the 
amplifier is switched off during an update, the controls will be unresponsive after the 
power is reapplied and the amplifier will produce no sound. The Tap 

3

ED will flash 

to indicate that the amplifier contains no valid firmware.

The amplifier must be connected to the 

)

lackstar Insider software to reinstall valid 

firmware. The update process will start automatically if the 

)

lackstar Insider software 

detects that the amplifier is in this state.

English

20

Содержание ID:10TVP

Страница 1: ...Owner s Manual Designed and Engineered by Blackstar Amplification UK ...

Страница 2: ...pparatus 12 6nly use attachments accessories speciÄed by the manufacturer 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to XualiÄed service personnel ervicing is reXuired when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the a...

Страница 3: ...oth Condensation can form on the inside of an ampliÄer if it is moved from a cold environment to a warmer location efore switching the unit on it is recommended that the unit be allowed to reach room temperature Unauthorised modiÄcation of this equipment is expressly forbidden by lackstar AmpliÄcation 3td Never push objects of any kind into ventilation slots on the equipment casing Do not expose t...

Страница 4: ...d and downloaded via the online community The U connector also allows you to record from your amp directly to your computer An emulated output MP3 line input and MIDI footswitching complete the package y using the unique oice control the patented I F and patent applied for True alve Power ID amplifiers allow unparalleled flexibility and ease of use enabling you to in effect design the sound in you...

Страница 5: ...ory reset it will be in ºDemo Mode The sound you hear will reÅect the physical position of the front panel knobs as it will be in Manual Mode All effects plus T P will be turned off All ampliÄer patch locations will contain lackstar factory defaults Patches can be created and stored in Demo Mode but the original factory default patches and settings will be restored each time the ampliÄer is turned...

Страница 6: ...e and the T P elector will be deactivated This setting is saved in a patch NOTE With T P off the power amplifier has a linear response and you will not be able to achieve the valve like sag compression and power that T P delivers English 11 USA UK Front Panel 1 Input Plug your guitar in here Always use a good quality screened guitar lead 2 Voice The oice control changes the preamp voicing ranging ...

Страница 7: ...Y Delay Press this switch to turn the delay effect on off or focus the effect for editing This setting is saved when you store a patch 13 REV Reverb Press this switch to turn the reverb effect on off or focus the effect for editing This setting is saved when you store a patch With all three of the effect switches the 3ED will show what state it is in LED Effect State Description 3ED not on Effect ...

Страница 8: ...ing a patch 19 Master Volume This controls the overall volume of your amplifier Turning it clockwise increases the volume This is a global setting and not saved when storing a patch If the master volume is at zero this allows for silent recording via the emulated output or U The emulated level is controlled via the preamp volume 20 Power Switch This switch is used to turn the amplifier on and off ...

Страница 9: ... Channels 1 4 Channel 1 activates the first patch within the currently active bank Channel 2 activates the second patch within the currently active bank Channel 3 activates the third patch within the currently active bank Channel 4 activates the fourth patch within the currently active bank 28 Recall Indicator The Recall Indicator shows if there is a mismatch between the current value of a paramet...

Страница 10: ...ad protection circuit and will cause damage to the amplifier Rear Panel 1 Mains Input The supplied detachable mains lead is connected here The lead should only be connected to a power outlet that is compatible with the voltage power and frequency requirements stated on the rear panel If in doubt get advice from a qualified technician 2 Speaker Outputs ID 60TVP ID 100TVP There are two parallel spea...

Страница 11: ...ware This is a non storable setting and will be switched off either when the U cable is removed or when the amplifier power is switched off When activated Re amping Mode allows the amplifier to accept a pre recorded dry guitar signal via U and return a fully processed audio signal This return signal can then be captured using recording software on the connected PC or Mac Firmware Update Firmware u...

Отзывы: