23
4. Maintenance
4.3 Disassembly
Step 1
Before disassembling the pump refer to safety
precautions. See exploded view drawings (chapter 6).
Removing rotorcase cover.
Remove rotorcase cover nuts (13) and cover (12).
Step 2
Removing rotors
Insert a plastic/wooden block between the two rotors (17)
to stop them turning.
Plastic or
wooden block
Step 3
Remove rotor retainer (22) and rotors. A rotor retainer
removal tool (supplied with all new pumps) is used for this
purpose by sliding the tool into the rotor retainer slot and
turning in an anti-clockwise direction.
Rotor retainer
removal tool
Step 4
Removing static seal components
Please see section 4.5 for seal removal.