BLACKMER GLOBAL DISPENSER PUMP
OPERATION AND MAINTENANCE INSTRUCTIONS
WITH PARTS LIST
MODEL: GDP
964800
INSTRUCTIONS AND
PARTS LIST NO. 1701-A00
Page 1 of 12
Section
1701
Effective
February 2004
Replaces October 2003
TABLE OF CONTENTS
Page
SAFETY DATA
..................................................................1-
2
OPERATION
.........................................................................
2
Pressure Control Valve (PCV) Adjustment............2
MAINTENANCE
..................................................................
2
Draining Pump.......................................................2
Strainer/Check Valve Removal..............................2
Strainer/Check Valve Installation...........................3
Pressure Control Valve (PCV) Removal................3
Pressure Control Valve (PCV) Installation.............3
Pump Cartridge Removal ......................................3
Pump Cartridge Installation ...................................4
Sump Float Removal.............................................4
Sump Float Installation ..........................................4
OIML Switch Removal...........................................5
OIML Switch Installation........................................5
REPAIR KITS PARTS LIST -
Standard Flow Pumps
...5
REPAIR KITS PARTS LIST -
UHF Pumps
...................6
PUMP PARTS LISTS
..............................................7-10
Models 102 & 201
..................................................7
Model 206
......................................................................
8
Models:
...........................................................................
M00955B107, 203, 204, 207, 208, 705, & 707
..
9
Model UHF : M00955B602, & 605
..........................
10
PUMP TROUBLESHOOTING
..........................................
11
NOTICE:
Blackmer GDP pumps MUST only be installed in
systems which have been designed by qualified
engineering personnel. The system MUST conform to
all applicable local and national regulations and safety
standards.
This manual is intended to assist in the operation and
maintenance of the Blackmer GDP pump, and MUST
be kept with the pump.
Blackmer GDP pump service shall be performed by
qualified technicians ONLY. Service shall conform to
all applicable local and national regulations and safety
standards.
Thoroughly review the pump instructions and hazard
warnings, BEFORE performing any work on the
Blackmer GDP pump.
Maintain ALL system and Blackmer GDP pump
operation and hazard warning decals.
SAFETY DATA
NOTE: Numbers in parentheses following individual parts
indicate reference numbers on the corresponding Blackmer
Parts List.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the manual, look for
one of the following signal words and be alert to the potential for
personal injury, death or major proper ty damage.
Warns of hazards that WILL cause serious personal injury,
death or major proper ty damage.
Warns of hazards that CAN cause serious personal injury,
death or major proper ty damage.
Warns of hazards that CAN cause personal injury
or proper ty damage.
NOTICE:
Indicates special instructions which are very
impor tant and must be followed.