Страница 1: ...The Loner Br idge Syst em ...

Страница 2: ...CONTENTS A b o u t t h e d e v i c e s S t a r t i n g y o u r s h i f t D u r i n g y o u r s h i f t G e n e r a t i n g M a n u a l A l e r t s E n d i n g y o u r s h i f t Q u e s t i o n s ...

Страница 3: ...ABOUT THE DEVICES ...

Страница 4: ...ice 95 Loners 1 Sat Cell OK Loner Bridge The Loner Device is the monitor and the Bridge is the communicator Cell Satellite Blackline Safety Network ABOUT THE DEVICE Loner Bridge 900 HOW DO LONER BRIDGE LONER 900 WORK TOGETHER ...

Страница 5: ...95 Loners 1 Sat Cell OK Power button LCD Display Menu navigation buttons SureSafe indicator light Battery indicator charging light ABOUT THE DEVICE Loner Bridge LONER BRIDGE COMPONENTS ...

Страница 6: ...er connected Battery level percentage Number of connected Loner 900 Devices Cell network signal strength Cell network connection Communication service indicator Satellite network signal strength Satellite network connection LCD EXPLAINED ...

Страница 7: ...ABOUT THE DEVICE Loner 900 Belt Clip Latch SureSafe monitoring light and power button LONER 900 COMPONENTS ...

Страница 8: ...STARTING YOUR SHIFT ...

Страница 9: ...ALWAYS turn Loner Bridge on BEFORE turning on Loner 900 95 Loners 1 Sat Cell OK ENDING YOUR SHIFT 1 2 ...

Страница 10: ...afe indicator light will flash while Loner Bridge connects to a network and the LCD will say Searching Once connected the SureSafe monitoring light will be SOLID GREEN 95 Loners 1 Sat Cell OK STARTING YOUR SHIFT TURNING ON YOUR LONER BRIDGE ...

Страница 11: ... of Loner Bridge has a clear view of the sky especially if you are outside of cell coverage If the SureSafe indicator light on Loner Bridge is flashing the device is not connected to the Blackline Safety Network and your safety is not monitored STARTING YOUR SHIFT ...

Страница 12: ...n The green SureSafe light will blink until it is connected to the Blackline Safety Network Once connected the light will be SOLID GREEN This means your safety is now monitored TURNING ON YOUR LONER 900 STARTING YOUR SHIFT ...

Страница 13: ...Clip the device to the side of your hip or to your chest pocket WEARING YOUR LONER STARTING YOUR SHIFT ...

Страница 14: ...Do not leave Loner unattended when powered on This can lead to false alerts STARTING YOUR SHIFT ...

Страница 15: ...DURING YOUR SHIFT ...

Страница 16: ...During your shift the device may ask you to confirm that you are OK when it detects one of the following No motion Fall detection Check in DURING YOUR SHIFT AUTOMATIC FEATURES ...

Страница 17: ... vibrations This will reset the check in timer before the automatic alarm sounds Your device will automatically check you in if you are driving over 35 km h 00 54 34 2 00 00 Before pre check in Check in timer reset DURING YOUR SHIFT PRE CHECK IN ...

Страница 18: ...otion Fall Detection Check in DURING YOUR SHIFT Pending Alarm If you re OK press the confirm button on the latch This returns Loner to normal function No notification is sent AUTOMATIC FEATURES IF YOU RE OK ...

Страница 19: ...period of time the device will go into high alarm This sends an alert notification The high alarm can be silenced by pressing and holding the button The alert notification still remains active Once an alert is acknowledged by monitoring personnel the loner will display a blue light AUTOMATIC FEATURES IF YOU CAN T CONFIRM ...

Страница 20: ...Emergency alert Audible Silent alert During your shift you may need to request help using one of the manual features DURING YOUR SHIFT MANUAL FEATURES ...

Страница 21: ...personnel DURING YOUR SHIFT The high alarm can be silenced by pressing and holding the button The alert notification still remains active Once an alert is acknowledged by monitoring personnel the loner will display a blue light Request help by pulling down the latch ...

Страница 22: ... 5 sec No audible or visual alarm is generated on the Loner device DURING YOUR SHIFT An alert notification will be sent to monitoring personnel No alert acknowledged blue light will be displayed on the device during a silent alert even if monitoring personnel have acknowledged the incident ...

Страница 23: ...BRIDGE MESSAGING ...

Страница 24: ...rpose of Bridge Text Messaging is for the device user to communicate to the monitoring personnel via their Bridge in areas where there is no cell service or cell phones are prohibited 95 Loners 1 Sat Cell OK BRIDGE MESSAGING ...

Страница 25: ...ds BRIDGE MESSAGING Return back to your Loner Bridge and check the LCD display for a message from Monitoring Personnel Ensure you read the message before moving to the next step 95 Loners 1 Sat Cell OK WHAT HAPPENS WHEN YOU RECEIVE A MESSAGE 95 Loners 1 Sat Cell OK Silence your Bridge by pressing the OK button three times ...

Страница 26: ...BRIDGE MESSAGING REPLYING TO A TEXT MESSAGE ...

Страница 27: ...BRIDGE MUSTERING ...

Страница 28: ...you see TeamAlert Muster 95 Loners 1 Sat Cell OK Press OK 95 Loners 1 Sat Cell OK Press the down button until you see start 95 Loners 1 Sat Cell OK Press OK 95 Loners 1 Sat Cell OK This will start a team muster and the Bridge will go into alarm The purpose of the Muster is to call employees back to the Bridge ...

Страница 29: ...0 95 Loners 1 Sat Cell OK When a muster is generated your Loner 900 will display the muster alarm To silence your device press and hold the latch for 3 seconds Once silenced the device will display only the solid yellow light Return back to your bridge ...

Страница 30: ... Cell OK 95 Loners 1 Sat Cell OK 95 Loners 1 Sat Cell OK BRIDGE MUSTERING ENDING A MUSTER FROM A BRIDGE 95 Loners 1 Sat Cell OK Press OK Press the down button until you see stop Press OK This will end the muster alarm ...

Страница 31: ...NOTIFICATIONS ...

Страница 32: ...T being monitored NOTIFICATIONS Low battery alarm Your Loner device is configured to signal to you when the battery falls below a certain configured percentage Low battery alarm is characterized by a short beep and a quick flash every 5 minutes Charge your device as soon as possible Link lost alarm Your Loner 900 may be configured to notify you if it loses connection with Loner Bridge Loner 900 95...

Страница 33: ...ENDING YOUR SHIFT ...

Страница 34: ...sually 3 seconds The device will begin its shutdown sequence and the SureSafe light will flash and then turn off once your Loner logs off from the Blackline Safety Network ENDING YOUR SHIFT Your safety is no longer being monitored TURNING OFF YOUR LONER DEVICE ...

Страница 35: ...ower button and hold for 3 seconds The device will begin its shutdown sequence and the SureSafe light will flash and then turn off once your Loner logs off from the Blackline Safety Network ENDING YOUR SHIFT TURNING OFF YOUR LONER BRIDGE ...

Страница 36: ...Always turn Loner 900 off Before turning off Loner Bridge Loner Bridge cannot be powered down until the SureSafe light on the Loner 900 has stopped flashing 95 Loners 1 Sat Cell OK ENDING YOUR SHIFT 1 2 ...

Страница 37: ...hours Insert the charger into the bottom of the device and connect to power source While the device is charging the red lights on the base will flash When Loner is charged the red lights will turn on continuously ENDING YOUR SHIFT CHARGING YOUR LONER 900 ...

Страница 38: ...s 1 Sat Cell OK 95 Loners 1 Sat Cell OK Insert the CHARGER into the bottom of the device and connect to power source While the device is CHARGING the top indicator light will flash RED When Loner Bridge is charged the RED light will turn on continuously ENDING YOUR SHIFT CHARGING YOUR LONER BRIDGE ...

Страница 39: ...SUMMARY SUMMARY ...

Страница 40: ...QUESTIONS ...

Страница 41: ...For m or e suppor t m at er ials Please visit suppor t blacklinesaf et y com Cust om er Car e 1 877 869 7212 0 0 4 9 R 1 2 0 1 6 0 6 0 6 ...