TABLE OF CONTENTS

Introduction...........................................................................3
.

BH1H.Special.Features....................................................4

The.Front.Panel.....................................................................5
The.Rear.Panel......................................................................6
Important.Information.About.Tubes.and.Tube.Products.............8
System.Block.Diagram.........................................................11
Technical.Specifications........................................................12

IMPORTANT SAFETY INSTRUCTIONS

  READ, FOLLOW, HEED, AND KEEP ALL INSTRUCTIONS AND WARNINGS.

  DO NOT OPERATE NEAR ANY HEAT SOURCE AND DO NOT BLOCK ANY VENTILATION OPENINGS ON THIS APPARATUS. FOR 

PROPER OPERATION, THIS UNIT REQUIRES 3” (75mm) OF WELL VENTILATED SPACE AROUND HEATSINKS AND OTHER AIR 

FLOW PROVISIONS IN THE CABINET.

  DO NOT USE THIS APPARATUS NEAR SPLASHING, FALLING, SPRAYING, OR STANDING LIQUIDS.

  CLEAN ONLY WITH LINT-FREE DRY CLOTH AND DO NOT USE CLEANING AGENTS.

  ONLY CONNECT POWER CORD TO A POLARIZED, SAFETY GROUNDED OUTLET WIRED TO CURRENT ELECTRICAL CODES AND 

COMPATIBLE WITH VOLTAGE, POWER, AND FREQUENCY REQUIREMENTS STATED ON THE REAR PANEL OF THE APPARATUS.

•  WHERE THE MAINS PLUG OR AN APPLIANCE COUPLER IS USED AS THE DISCONNECT DEVICE, THE DISCONNECT DEVICE 

SHALL REMAIN READILY OPERABLE.

  PROTECT THE POWER CORD FROM DAMAGE DUE TO BEING WALKED ON, PINCHED, OR STRAINED.

  UNPLUG THE APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME.

  ONLY USE ATTACHMENTS, ACCESSORIES, STANDS, OR BRACKETS SPECIFIED BY THE MANUFACTURER FOR SAFE OPERATION 

AND TO AVOID INJURY.

  WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK OR FIRE, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

  SERVICE MUST BE PERFORMED BY QUALIFIED PERSONNEL.

  OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEVELS. CONTINUED EXPOSURE TO HIGH SOUND 

PRESSURE LEVELS CAN CAUSE PERMANENT HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR 

PROTECTION IS RECOMMENDED IF UNIT IS OPERATED AT HIGH VOLUME.

•  WARNING: THIS UNIT REQUIRES A SAFETY GROUNDED OUTLET WIRED TO CURRENT ELECTRIC CODES HAVING THE 

LINE SUPPLY VOLTAGE, POWER, AND FREQUENCY IDENTIFIED ON THE REAR OF THE UNIT. THE OUTLET MUST REMAIN 

ACCESSIBLE TO DISCONNECT THE UNIT IF A FAULT SHOULD ARISE WHILE IN USE. THIS UNIT SHOULD BE UNPLUGGED WHEN 

NOT IN USE.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING:  TO  REDUCE  THE  RISK  OF  FIRE  OR  ELECTRIC 

SHOCK,  DO  NOT  EXPOSE  THIS  APPARATUS  TO  RAIN  OR 

MOISTURE. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO 

NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL"

“ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES.”

"REFERREZ-VOUS AU MANUAL D'UTILISATION"

EXPLANATION OF GRAPHICAL SYMBOLS:

EXPLICACION DE SIMBOLOS GRAFICOS:

EXPLICATION DES SYMBÔLES GRAPHIQUES:

"DANGEROUS VOLTAGE"

“VOLTAJE PELIGROSO”

"DANGER HAUTE TENSION"

=

=

PRECAUCION

RIESGO DE CORRIENTAZO

NO ABRA

PRECAUCION:  PARA  REDUCIR  EL  RIESGO  DE  INCENDIOS  O  DESCARGAS 

ELECTRICAS,  NO  PERMITA  QUE  ESTE  APARATO  QUEDE  EXPUESTO  A  LA 

LLUVIA O LA HUMEDAD. PARA DISMINUOIR EL RIESGO DE CORRIENTAZO. 

NO ABRA LA CUBIERTA. NO HAY PIEZAS ADENTRO QUE EL USARIO PUEDO 

REPARAR DEJE TODO MANTENIMIENTO A LOS TECHNICOS CALIFICADOS.

ATTENTION

RISQUE D'ELECTROCUTION

NE PAS OUVRIR

ATTENTION:  PROTÉGEZ  CET  APPAREIL  DE  LA  PLUIE  ET  DE  L'HUMIDITÉ 

AFIN  D'ÉVITER  TOUT  RISQUE  D'INCENDIE  OU  D'ÉLECTROCUTION.  POUR 

REDUIRE D'ELECTROCUTION NE PAS ENLEVER LE COUVERCLE. AUCUNE 

PIECE  INTERNE  N'EST  REPRABLE  PAR  L'UTILISATEUR.  POUR  TOUTE 

REPARATION, S'ADRESSER A UN TECHNICIEN QUALIFIE.

Correct disposal of this product: 

This symbol indicates that this product should not be disposed of with your household waste, 

according  to  the WEEE  directive  (2002/96/EC)  and  your  national  law. This  product  should  be  handed  over  to  an  authorized 
collection site for recycling waste electrical and electronic equipment (EEE). Improper handling of this type of waste could have 
a possible negative impact on the environment and human health due to potentially hazardous substances that are generally 
associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the effective 
usage of natural resources. For more information about where you can drop off your waste equipment for recycling, please contact 
your local city office, waste authority, or your household waste disposal service.

Содержание BH1H Killer Ant

Страница 1: ...BH1H Killer Ant Guitar Amplifier Head User s Guide ...

Страница 2: ...IT SHOULD BE UNPLUGGED WHEN NOT IN USE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL ES NECESARIO QU...

Страница 3: ...tube amp sounds Pluck out a few chimey riffs and then dig in nice and hard so it breaks up and growls at you a bit That s a real amp you re playing there friend While you re at it plug it into your favorite 4 x 12 cab Oh yeah the Ant can push your best effort through just about anything you plug it into Don t let the size fool you And how about that build quality Just like all Blackheart Engineeri...

Страница 4: ...er amp tubes DC filament power supply for all tubes Volume Control the rest is up to you 16 gauge 1 5 mm thick folded U channel steel chassis Double sided custom color PCB with 2 oz copper traces 15 ply 18 mm thick void free birch plywood construction 16 ohm 8 ohm and 4 ohm speaker outputs Lovely red on light ...

Страница 5: ...amplifier on and off 2 INDICATOR LAMP This illuminates when the amplifier is turned on power that is 3 VOLUME Use this to adjust the output level 4 INPUT Use this jack to connect your guitar to the amplifier using a high qual ity shielded instrument cable 1 2 3 4 ...

Страница 6: ...ated for 16 ohm speaker cabinets only such as the Blackheart BH110 BH112 BH412SL or BH412ST 7 8 OHMS The 8 ohm speaker output jack is designated for use with one 8 ohm speaker cabinet or two 16 ohm cabinets that are connected parallel 8 4 OHMS The 4 ohms speaker output jack is designated for use with one 4 ohm speaker cabinet or two 8 ohm cabinets that are connected parallel Connecting speaker cab...

Страница 7: ...RED TRADEMARKS OF LOUD TECHNOLOGIES INC MAX POWER INPUT 75WATTS RMS 16 OHM PARALLEL JACKS R O C K O U T C ERTIFIED SERIAL NUMBER MANUFACTURING DATE From Power Amplifier 16Ω 16Ω 8Ω Two 16 ohm cabinets Total Load 8 ohm Use the 8 ohm output jack One 8 ohm cabinet Total Load 8 ohm Use the 8 ohm output jack Speaker Cabinets in parallel One 16 ohm cabinet Total Load 16 ohm Use the 16 ohm output jack 16Ω...

Страница 8: ...ubes and their associated driver tubes After turning off the power and disconnecting the amplifier from the power source carefully check the tubes in bright light for cracks or white spots inside the glass or any other appar ent damage Then with the power on view the tubes in a dark room Look for preamplifier tubes that do not glow at all or power tubes that glow excessively red Whenever you repla...

Страница 9: ...on your amp is like setting the idle on your car If it s too high or hot it s running away with you and if it s too low or cold it will choke when you step on it The bias is adjusted at the factory in accordance with the type of power tube s installed in your amplifier It is important to point out that tubes of the same type and specification typi cally exhibit different performance characteristic...

Страница 10: ...er is equipped with self biasing circuitry This should be done ONLY at a qualified service center Improper biasing could result in the tubes running too hot which greatly reduces the life of the tubes or too cold which results in distorted sound regardless of level settings Do not play the amplifier if it exhibits these symptoms get the bias checked adjusted immediately to prevent tube failure and...

Страница 11: ...ith Standards LVD 92 31 EEC 93 68 EEC 73 23 EWG Safety EN60065 EMC EN55013 EN55020 EN55022 EN55103 EN61000 3 2 EN61000 3 3 The official Declaration of Conformity for this product is kept on file at LOUD Technologies Inc 16220 Wood Red Road NE Woodinville WA 98072 Tel 1 866 858 5832 System Block Diagram 16 OHM SPEAKER OUTPUTS 8 OHM 4 OHM INPUT VOLUME V1A V1B V2A V2B PRE SET EQ B ...

Страница 12: ...ever spray your Killer Ant with Ant Killer Crate continually develops new products as well as improves existing ones For this reason the specifications and information in this manual are subject to change without notice Blackheart and Crate are registered trademarks of LOUD Technologies Inc All other brand names mentioned are trademarks or registered trademarks of their respective holders and are ...

Отзывы: