background image

 

Contents 

 
FEDERAL COMMUNICATIONS COMMISSION and CANADIAN DEPARTMENT OF COMMUNICATIONS 
RADIO FREQUENCY INTERFERENCE STATEMENT

……………………………………………………………… 

   
 
  

NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT 
INSTRUCCIONES DE SEGURIDAD

 ………………………………………………………………………………….. 

  
  1 

FCC REQUIREMENTS FOR TELEPHONE-LINE EQUIPMENT

 …………………………………………………… 

  3 

CERTIFICATION NOTICE FOR EQUIPMENT USED IN CANADA

 ……………………………………………….. 

  4 

 
1. Introduction 

1.1 Introducing the Phone Line Manager 208B

…………………………………………………………… 

  5 

1.2 Before you begin

………………………………………………………………………….………………. 

  5 

1.3 A note about telephone company services

…………………………………………….……………...    5 

1.4 Set up

……………………………………………………………………………………………………….. 

  6 

 

2. Installation 

2.1 Placing the Phone Line Manager 208B

 …………………………………………..….………………... 

   7 

2.2 Ports on the Phone Line Manager 208B

 ……………………………………………………………… 

   7 

2.3 Connecting the Phone Line Manager 208B

 ……………………………………....………………….. 

   7 

2.4 Connecting the telephone line cords

………………………………………………………………….. 

   8 

2.5 Installing at the DEMARC

……………………………………………………………………………….. 

   8 

2.6 Installation with 1 or 2 telephone lines

………………………………………………………………... 

   8 

2.7 Installation on a telephone system

…………………………………………………………………….. 

   9 

2.8 Installation on a telephone system using a 66 block

……………………………….………………. 

   9 

 
 

3. Automatic Operation

………………………………………………………..………………………

 

10 

 

4. Using the Phone Line Manager 208B 

4.1 Special operating notes

…………………………………………………………………………………. 

  10 

4.2 Answering incoming calls

………………………………………………………………………………. 

  11 

4.3 Placing outbound calls

...………………………………………………………………………………… 

  11 

4.4 Receiving a computer call

………………………………………………………………………………. 

  11 

 

5. Operational descriptions for the Phone Line Manager 208B 

5.1 Inbound call processing

…………………………………………………………………………………. 

11 

5.2 Outbound line seeking

…………………………………………………………………………………… 

11 

5.3 LED’s

……………………………………………………………………………………………………….. 

12 

5.4 Busy tones

………………………………………………………………………………………………… 

12 

5.5 CPC detection

…………………………………………………………………………………………….. 

12 

5.6 # (pound) key

……………………………………………………………………………………………… 

12 

5.7 Port lock up provision

……………………….………………………………………………………….. 

12 

5.8 Delay Port Ringing

…….………………………………………………………………….……………… 

12 

5.9 Power Failure

……………..……………………………………………………………….……………… 

12 

 

 
 
 
 
 

Содержание Phone Line Manager 208B

Страница 1: ... M Monday to midnight Friday 877 877 BBOX FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION ...

Страница 2: ...e Line Manager 208B 7 2 3 Connecting the Phone Line Manager 208B 7 2 4 Connecting the telephone line cords 8 2 5 Installing at the DEMARC 8 2 6 Installation with 1 or 2 telephone lines 8 2 7 Installation on a telephone system 9 2 8 Installation on a telephone system using a 66 block 9 3 Automatic Operation 10 4 Using the Phone Line Manager 208B 4 1 Special operating notes 10 4 2 Answering incoming...

Страница 3: ...adio Interference Regulation of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada NOM STATEMENT NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATE...

Страница 4: ...es de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atención a los contactos y receptáculos donde salen del aparato 14 El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deberá ser localizada lejos de las linea...

Страница 5: ... in its technical operations and procedures If any such changes affect the compatibility or use of this device the telephone company is required to give adequate notice of the changes 5 If the telephone company requests information on what equipment is connected to their lines inform them of a The telephone number that this unit is connected to b The ringer equivalence number c The USOC jack requi...

Страница 6: ...ertified equipment should be made by an authorized Canadian maintenance facility in this case your supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telep...

Страница 7: ...r needs Unpack and check for the following items Installation kit includes the following 1 mounting template 2 mounting screws If any of these items are missing or damaged call 724 746 5500 NOTE According to standard industry practice surge protection is recommended for the power and the telephone line connections 1 3 A note about telephone company services If you currently subscribe or plan to su...

Страница 8: ... that consists of one or more lines with one or more phones The Phone Line Manager 208B has one operating mode automatic and can be connected at the DEMARC The Phone Line Manager 208B will Answer the calls automatically Route calls to Ports 1 and 2 Transfer fax calls on Line 2 to Port 8 or calls to the other ports when transfer codes are detected ...

Страница 9: ...nt as follows 1 Connect Line 1 to this port You can connect a two line telephone cord to this port for Line 1 and Line 2 2 Connect Line 2 to this port 3 Connect a telephone or KSU to receive calls on Line 1 4 Connect a telephone or KSU to receive calls on Line 2 5 Connect a computer modem or other data device 6 Connect a computer modem or other data device 7 Connect a computer modem or other data ...

Страница 10: ... or two telephone lines If you are using only one telephone line and are going to connect a fax to the Phone Line Manager 208B connect the single line to Line 2 enabling automatic fax detection and routing to Port 8 If you are not using a fax connect a single line to either Line 1 or Line 2 If you are using two lines and are going to connect a fax to the Phone Line Manager 208B connect the line th...

Страница 11: ...o operate properly it must be in front of the telephone system Connect the other equipment as previously shown All equipment on that line telephone system fax computer modem etc must connect directly to the Phone Line Manager 208B Caution Do not plug the Phone Line Manager 208B into a telephone system phone jack You may damage the phone system or the Phone Line Manager 208B 2 8 Installation on a t...

Страница 12: ...2 a maximum of 20 times each If either port device does not answer within 20 rings the call will be disconnected CHAPTER 4 Using the Phone Line Manager 208B 4 Using the Phone Line Manager 208B 4 1 Special operating notes Before operating the Phone Line Manager 208B be sure that you understand the following information concerning the telephone equipment that is used with the Phone Line Manager 208B...

Страница 13: ... long distance For remote access to any of the ports on the Phone Line Manager 208B instruct the caller to use the following modem dialing string in the communication software For example we are going to access Port 3 LOCAL CALL ATDT phone number 33 33 33 LONG DISTANCE ATDT phone number 33 33 33 The calling modem picks up its phone line and dials the phone number The comma tells the modem to wait ...

Страница 14: ... is established If CPC is detected the Phone Line Manager 208B will hang up the telephone line and monitor the port off hook If the port remains off hook the Phone Line Manager 208B will produce a busy tone and wait for the device to go on hook and then off hook for the device to access the telephone line When an inbound call tries to access the port that is locked up it will receive a busy tone 5...

Страница 15: ...13 Copyright 2003 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 725 746 0746 ...

Отзывы: