background image

24/7 TECHNICAL SUPPORT AT 1.877.877.2269 OR VISIT BLACKBOX.COM

12-PORT 10G 

IP NETWORK 

SWITCH

HARDWARE INSTALLATION GUIDE

EMS10G12

pq

1

pq

2

pq

pq

pq

pq

pq

pq

pq

pq

pq

pq

pq

3

pq

4

5

pq

6

7

pq

8

9

pq

10

pq

11

pq

12

14

13

15

i

lOlO

lOlO

Содержание EMS10G12

Страница 1: ...ICAL SUPPORT AT 1 877 877 2269 OR VISIT BLACKBOX COM 12 PORT 10G IP NETWORK SWITCH HARDWARE INSTALLATION GUIDE EMS10G12 pq 1pq2 pq pq pq pq pq pq pq pq pq pq pq 3pq4 5pq6 7pq8 9pq10 pq 11pq12 14 13 15 i lOlO lOlO ...

Страница 2: ...te Selection 12 3 2 Cabinet Placement 12 3 3 Rackmounting 12 3 4 Switch Ground 12 3 5 Fans and Airflow 13 3 6 Power 13 3 7 Storing Components 13 4 INSTALLING THE SWITCH 14 4 1 Unpacking Steps 14 4 2 Ground Cable 14 4 3 Rack or Cabinet Hardware Installation 14 Rackmount Safety Considerations 15 4 4 Half Rack Unit RU Front Rack Installation 15 4 5 Switch Installation 18 Switch Removal 19 4 4 Optics ...

Страница 3: ...Technical Support 31 8 2 Shipping and Packaging 31 APPENDIX A REGULATORY INFORMATION 32 A 1 USA Federal Communications Commission Statement 32 A 2 NOM Statement 33 A 3 European Union EMC Directive Conformance Statement 34 A 4 Japan VCCI Compliance for Class A Equipment 34 A 5 Korean Certification of Compliance 35 A 6 Safety Certifications and Compliance Agency Certifications 35 A 7 Electromagnetic...

Страница 4: ...n handling this equipment WARNING Only trained and qualified personnel can install this equipment Read this guide before you install and power up this equipment This equipment contains two power cords Disconnect both power cords before servicing WARNING This equipment contains optical transceivers which comply with the limits of Class 1 laser radiation CLASS 1 LASER PRODUCT WARNING When no cable i...

Страница 5: ...ty Weighted Random Early Detect PERFORMANCE Switching Capacity 960 Gbps Forwarding Capacity 720 Mpps Frame Size 9416 bytes Packet Buffer Memory 12 MB CPU Memory 4 GB MAC Addresses 272K in Scaled L2 mode ARP Table 200K in Scaled L3 routes mode IPv4 routes 200K in Scaled L3 routes mode IPv6 hosts 64K IPv6 routes 130K in scaled L3 routes mode Multicast hosts 8K Link aggregation 16 links per group 128...

Страница 6: ...s 12 10 G 3 100 G 12 10 G 12 25 G 24 10 G 12 10 G 6 50 G 2 2 FEATURES 12 fixed 10GbE SFP ports 3 fixed 100GbE QSFP28 ports 1 Micro USB B serial console management port 1 One RJ 45 serial console management port 1 RS 232 serial console port 1 universal serial bus USB Type A port for more file storage 1 ESD jack 1 2 core Rangeley C2338 central processing unit CPU 75 watts TDP 1 7 GHz one memory chan...

Страница 7: ...q pq pq pq pq pq pq pq pq pq pq pq 1 6 1 1 5 4 3 2 8 7 FIGURE 2 1 FRONT PANEL OF THE SWITCH TABLE 2 1 FRONT PANEL COMPONENTS NUMBER IN FIGURE 2 1 COMPONENT DESCRIPTION 1 12 SFP optical ports SFP modules install here Links to fiberoptic devices 2 2 QSFP28 optical ports SFP modules install here Links to fiberoptic network 3 Stack ID Indicates stacking master stacking slave or standalone mode 4 1 Eth...

Страница 8: ...2 SFP 10GBASE R 1310 nm single mode 10 km LSP431 SFP 10 Gb Extended Operating Temperature Diagnostics 850 nm Multimode Fiber 300 m 2 5 2 BACK PANEL Figure 2 2 shows the back panel of the switch Table 2 3 describes its components 1 2 1 2 3 FIGURE 2 2 BACK PANEL OF THE SWITCH TABLE 2 3 BACK PANEL COMPONENTS NUMBER IN FIGURE 2 2 COMPONENT DESCRIPTION 1 3 ground holes Attach to ground 2 2 fans Keep th...

Страница 9: ...FP28 port LEDs Link Activity LEDs See Table 2 8 for more information 3 Stack ID Off No power Solid green Displays a hex digit representing the stack unit ID 4 Master LED Off Switch is in Stacking Slave mode Solid green System is in Stacking Master or Standalone mode 5 System LED Solid green Normal operation Blinking green Booting Solid yellow Critical system error Blinking yellow Non critical syst...

Страница 10: ... expected RPM Solid yellow Fan failed or loss of cooling redundancy PSU LED Off No power Solid green Normal operation Flashing yellow PSU failure Flashing green Firmware update Locator LED System Beacon Off Locator function is disabled Flashing blue Locator function is enabled Master LED Off System is the stack slave Solid green System is the stack master or a standalone unit 7 Segment LED Off No ...

Страница 11: ...erating at a lower speed Flashing yelllow Port activity at 100G on a QSFP28 port Flashing yellow 1 second on off Port beacon Link Activity LED 4 25 G mode or 4 10 G mode Off No link Solid green Link operating at maximum speed 4 x 25G on a QSFP28 port or 4 x 10G on a QSFP port Flashing green Link activity operating at maximum speed 4 x 25G on a QSFP28 port Solid yellow Link operating at a lower spe...

Страница 12: ...oper ventilation and access Install the switch in information technology rooms in accordance with Article 645 of the National Electric Code and NFPA 75 For more information about switch storage and environmental temperatures see the Specifications chapter in this manual 3 2 CABINET PLACEMENT Install the EMS10G12 only in indoor cabinets designed for use in a controlled environment Do not install th...

Страница 13: ...nal Electrical Code ANSI NFPA 70 where applicable The switch is powered up as soon as the power cord is connected between the switch and the power source CAUTION Always disconnect the power cable before you service the power supply slots CAUTION Use the power supply cord as the main disconnect device on the AC switch Make sure that the socket outlet is located installed near the equipment and is e...

Страница 14: ...ed ground wire The ground cable is not included To properly ground the chassis Black Box recommends a one or two hole lug M4 hole size The ground lugs must be a UL recognized crimp type lug CAUTION Grounding conductors must be made of copper Do not use aluminum conductors NOTE Coat the one hole lug with an anti oxidant compound before crimping Also bring any unplated mating surfaces to a shiny fin...

Страница 15: ...maximum ambient temperature of the switch Reduced air flow Install the equipment in the rack so that the amount of airflow required for safe operation of the equipment is not compromised Reliable grounding Maintain reliable grounding of rack mounted equipment Pay particular attention to the supply connections other than the direct connections to the branch circuit for example use of power strips D...

Страница 16: ... 7 TECHNICAL SUPPORT 1 877 877 2269 CHAPTER 4 INSTALLING THE SWITCH FIGURE 4 1 DUAL TRAY AND RACKMOUNTING RAIL 3 Attach the rail to the dual tray Slide the rail back until it locks into place 4 Repeat with the other side FIGURE 4 2 ATTACH DUAL TRAY AND RACKMOUNTING RAILS ...

Страница 17: ...ach the front dual tray switch rails to the 4 post rack from the front Secure the dual tray to the rack using two user supplied screws for each rack post FIGURE 4 3 ATTACH DUAL TRAY FRONT TO THE 4 POST RACK FRONT 7 Attach the rear dual tray switch rails to the 4 post rack from the rear Secure the dual tray to the rack using two user supplied screws for each rack post FIGURE 4 4 ATTACH DUAL TRAY RE...

Страница 18: ...H 8 Tighten all mounting screws to securely mount the dual tray into the 4 post rack FIGURE 4 5 SECURE THE DUAL TRAY IN THE 4 POST RACK 4 5 SWITCH INSTALLATION Install one or two half RU switches in the four post rack mounted dual tray 1 Install one switch into either dual tray slot from the front FIGURE 4 6 INSTALL AN EMS10G12 SWITCH ...

Страница 19: ... the dual tray The front switch latch snaps the switch into place 1 FIGURE 4 7 DUAL TRAY STOP FEATURE 2 If you are installing two switches insert the second switch in the open dual tray slot SWITCH REMOVAL Remove the switch from the dual tray from the front of the four post rack Push in the front switch latches according to the latch arrows and pull out the switch FIGURE 4 8 SWITCH RELEASE LATCHES...

Страница 20: ...Gb Extended Operating Temperature Diagnostics 850 nm Multimode Fiber 300 m CAUTION ESD damage can occur if components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the EMS10G12 switch and its components WARNING When working with optical fibers follow all warning labels and always wear eye protection Never look directly into the end of a terminated or untermi...

Страница 21: ...al modules NOTE A US AC power cable is included for powering up an AC power supply You must order all other power cables separately NOTE ESD damage can occur if components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the switch and its components POWER UP SEQUENCE When the switch powers up the fans immediately come on at high speed The fan speed slows as th...

Страница 22: ...re version of the replacement switch is the same as the previously installed switch show os version If the software versions do not match upgrade the replacement switch software using the procedure included with the firmware download 7 Copy the backed up switch configuration to the new switch copy tftp hostip filepath running config 8 Install the new switch in the dual tray If you are using the fa...

Страница 23: ...ground strap when handling the EMS10G12 and its components 5 1 COMPONENTS The following power supply is available for the EMS10G12 switch AC power supply with integrated fan Power supply 1 PSU1 is on the left side of the chassis power supply 2 PSU2 is on the right side of the chassis 1pq2 3pq4 5pq6 7pq8 9pq10 pq 11pq12 14 13 15 i lOlO lOlO pq pq pq pq pq pq pq pq pq pq pq pq 1 STACK ID FIGURE 5 1 ...

Страница 24: ...POWER SUPPLIES AC POWER CABLE CLIPS After you connect the AC power cable to the switch attach the metal wire clip to the switch over each AC power cable as shown FIGURE 5 2 AC POWER CABLE CLIPS PSU LEDS Solid green Input is OK Flashing yellow There is a fault with the PSU Flashing green system update Off PSU is off ...

Страница 25: ...tween fan replacements Check the environmental factors regularly An increase in temperature and or particulate matter in the air might affect performance for example new equipment installation CAUTION Check the fans at six month intervals and replace them as necessary Regularly monitor the speeds of the fans to accurately determine replacement intervals 6 1 COMPONENTS The following are the EMS10G1...

Страница 26: ...0 baud rate NOTE Before starting this procedure make sure that your PC has a 9 pin serial port and that you have a terminal emulation program already installed and running on the PC NOTE If your PC s serial port cannot accept a female DB9 connector acquire a DB9 male to male adapter 1 Install the provided RJ 45 connector side of the provided cable into the switch console port 2 Install the DB9 fem...

Страница 27: ...into the USB B console port on the switch 4 Power on the switch 5 Install the necessary USB device drivers To download the drivers contact Black Box Technical Support at 877 877 2269 or info blackbox com 6 Open your terminal software emulation program to access the switch 7 Confirm the terminal settings on your terminal software emulation program are as follows 115200 baud rate No parity 8 data bi...

Страница 28: ... Add a device to the file systems table fstab and mount the file systems recommended ONIE vi etc fstab FSTAB entry for the ONIE BOOT partition mounted on boot LABEL ONIE BOOT mnt onie boot ext4 defaults rw errors remount ro 0 1 dev sdb mnt usb vfat defaults 0 1 ONIE mount a The mount a command mounts all the file systems as indicated in the etc fstab file 7 2 BEFORE YOU INSTALL AN OS After powerin...

Страница 29: ...E For downloading and updating ONIE from a URL ONIE Embed ONIE For downloading and updating ONIE from a URL and erases any installed O ONIE Diag ONIE Run Diagnostic package for EMS10G12 Run Black Box Networking Diagnostic package for platform During the initial setup the switch boots to ONIE Install ONIE Install boots with ONIE Discovery to the console ONIE 7 2 3 ONIE SERVICE DISCOVERY ONIE attemp...

Страница 30: ...55 255 255 0 To display the IP address use the ifconfig eth0 command as shown ONIE ifconfig eth0 eth0 Link encap Ethernet HWaddr 90 B1 1C F4 9C 76 inet addr 10 11 53 33 Bcast 10 255 255 255 Mask 255 0 0 0 inet6 addr fe80 92b1 1cff fef4 9c76 64 Scope Link UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 18 errors 0 dropped 0 overruns 0 frame 0 TX packets 24 errors 0 dropped 0 overruns 0 ...

Страница 31: ...We will be able to provide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse 8 2 SHIPPING AND PACKAGING If you need to transport or ship your switch Package it carefully We re...

Страница 32: ...ration of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures necessary to correct the interference at their own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Dell Networking is not responsible for any radio or television interference caused by us...

Страница 33: ...etes que impidan el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el apa...

Страница 34: ...h the limits for Class A Information Technology Equipment according to CISPR 22 European Standard EN 55022 The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment WARNING This is a Class A product In a domestic environment this device may cause radio interference in which ca...

Страница 35: ...1 1st Edition EN 60825 1 Safety of Laser Products Part 1 Equipment Classification Requirements and User s Guide EN 60825 2 Safety of Laser Products Part 2 Safety of Optical Fibre Communication Systems FDA Regulation 21CFR 1040 10 and 1040 11 IEC 60950 1 2nd Ed including all National Deviations and Group Differences A 7 ELECTROMAGNETIC COMPATIBILITY A 7 1 EMISSIONS International CISPR 22 2006 Class...

Страница 36: ... system according to applicable local and national regulations Black Box encourages owners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed Waste Electrical and Electronic Equipment WEEE Directive for Recovery Recycle and Reuse of IT and Telecommunications Products Black Box switches are labeled in accordance with European Directive 2002 96 ...

Страница 37: ...ve consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any time without notice B 2 TRADEMARKS USED IN THIS MANUAL Black Box and the Black Box logo type and mark are registered trademarks of Black Box Corporation Any other trademarks mentioned in this manual are...

Страница 38: ...__________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ ____________________________________________________________________________________________...

Страница 39: ...__________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ ____________________________________________________________________________________________...

Страница 40: ...NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 COPYRIGHT 2018 BLACK BOX CORPORATION ALL RIGHTS RESERVED EMS10G12_INSTALL_REV1 PDF ...