![Blackberry CoolMIR V2 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/blackberry/coolmir-v2/coolmir-v2_user-manual_2766968011.webp)
11
CoolMir BES Setup Guide
Third party applications are restricted from use of certain low-level application interface programs and drivers
because of the high security features of the BlackBerry handheld. Therefore to enable the CoolMIR keyboard
driver on a BlackBerry that is activated by BlackBerry Enterprise Server (BES), the BES administrator should
perform the following.
Note to the BES Administrator :
••••
Research In Motion (RIM) BlackBerry requires a third party application that uses Controlled APIs
such as Event Injector API to be given permission by the BES administrator.
••••
This Controlled API must be signed with a key, or signature, provided by RIM before the application
.cod files can be loaded onto the BlackBerry Wireless Handheld. CoolMIR driver uses this Event
Injector API and is signed by RIM BlackBerry.
••••
Man & Machine, Inc. is a BlackBerry Alliance Member. You can verify this by going to
https://www.blackberry.com/ThirdParty/searchProduct.jsp?compID=1000813&productID=1028441.
••••
If you have any question or concern you can contact us using [email protected] or
(301) 341-4900.
BlackBerry Enterprise Server for Microsoft Exchange version 4.0 Handheld Management Guide
http://www.blackberry.com/knowledgecenterpublic/livelink.exe/fetch/2000/8067/645045/7963/7965/729294/729295/Handheld_M
anagement_Guide.pdf?nodeid=729296&vernum=0
Setup third-party applications (Wireless connection)
Complete all prior steps before starting this procedure.
1. Create an
applications
folder in
Program Files\Common Files\Research In Motion\Shared\
2. Create a subfolder under the
Program Files\Common Files\Research In Motion\Shared\applications\
directory for each third-party application. Copy the handheld installation files (.ALX & .COD) files to
this directory.
3.
Index the applications
by specifying the loader /index command from the command prompt. [See
command below: ]
Go to: C:\Program Files\Common Files\Research In Motion\Apploader
Type the command: Loader.exe /Index
Share Handheld Software and upgrade tools
1.Verify that the handheld upgrade software is installed in <drive:>\Program Files\Common Files\Research
In Motion as described above.
2. Share <drive:>\Program Files\Common Files\Research In Motion.
3. Set the permission attributes to Read-only.