Black Max BM903601 Скачать руководство пользователя страница 20

Page 16  — English

 

Remove the filter element. 

 

If the filter element is dirty, clean with warm, soapy water. 
Rinse and let dry. 

 

Apply a light coat of engine lubricant to the element, then 
squeeze it out.

 

Replace the element in the air filter unit.

 

Replace the air filter cover and rotate knob clockwise to 
secure.

NOTE

:  Do not run the generator without the air filter. Rapid 

engine wear will result.

CHANGING ENGINE LUBRICANT

See Figure 15.

 

Remove the oil cap/dipstick.

 

Place a container underneath the oil drain plug to collect 
used lubricant as it drains.

 

Unscrew the oil drain plug and remove.

 

Allow lubricant to drain completely.

 

NOTE: 

Drain the lubricant while the engine is still warm 

but not hot. Warm lubricant will drain quickly and more 
completely.

 WARNING: 

Do not change engine lubricant while it is hot. Accidental 
contact with hot engine lubricant could result in serious 
burns.

 

Reinstall the oil drain plug and tighten securely.

 

Refill with lubricant following the instructions in the 
 

Checking/Adding Lubricant

 section. For amount of 

lubricant needed to refill, see 

Product Specifications 

earlier in this manual or the accompanying engine manual, 
if applicable.

 

Reinstall the oil cap/dipstick.

NOTE

: Used lubricant should be disposed of at an ap-

proved disposal site. See your local lubricant retailer for 
more information.

SPARK PLUG MAINTENANCE

See Figure 16.

The spark plug must be properly gapped and free of deposits 
in order to ensure proper engine operation. To check:

 

Remove the spark plug cap.

 

Clean any dirt from around base of spark plug.

 

Remove spark plug using wrench (not included).

 

Inspect spark plug for damage, and clean with a wire 
brush before reinstalling. If insulator is cracked or chipped, 
spark plug should be replaced. For replacement spark 
plug, see 

Product Specifications 

earlier in this manual 

or the accompanying engine manual, if applicable.

 

Measure plug gap. The correct gap is 0.028−0.031 in. 

(0.7– 0.8 mm). To widen gap, if necessary, carefully bend 
the ground (top) electrode. To lessen gap, gently tap 
ground electrode on a hard surface.

 

Seat spark plug in position; thread in by hand to prevent 
cross-threading.

 

Tighten with wrench to compress washer. If spark plug 
is new, use 1/2 turn to compress washer appropriate 
amount. If reusing old spark plug, use 1/8 to 1/4 turn for 
proper washer compression. 

 

NOTE

:  An improperly tightened spark plug will become 

very hot and could damage the engine.

 

Reinstall the spark plug cap.

CLEANING THE EXHAUST PORT AND 
MUFFLER

Depending on the type of fuel used, the type and amount of 
lubricant used, and/or your operating conditions, the exhaust 
port and muffler may become blocked with carbon deposits. 
If you notice a power loss with your gas-powered products, 
you may need to remove these deposits to restore perfor-
mance. We highly recommend that only qualified service 
technicians perform this service.

SPARK ARRESTOR

See Figure 17.

NOTICE:

This product is equipped with a spark arrestor that has 
been evaluated by the USDA Forest Service; however, 
product users must comply with Federal, State, and local 
fire prevention regulations. Check with appropriate au-
thorities. Contact customer service or a qualified service 
center to purchase a replacement spark arrestor.

Inspect the spark arrestor for breaks or holes. Clean or 
replace if necessary. 

 

Inspect the spark arrestor for breaks or holes. Clean or 

replace if necessary. 

 

Use a brush (not provided) to remove carbon deposits from 

the spark arrestor screen as needed.

DRAINING FUEL TANK/CARBURETOR

See Figures 18 - 20.

To help prevent gum deposits in the fuel system, drain the 
fuel from the tank and carburetor before storing.

DRAINING THE FUEL TANK

 

Turn off the generator.

 

Turn the fuel valve to the 

OFF

 position.

 

Push the fuel valve knob through the generator housing 

and pull down slightly to gain access to the hose barb. 

MAINTENANCE

Содержание BM903601

Страница 1: ...sticas 11 Armado 12 13 Funcionamiento 13 16 Mantenimiento 17 20 Correcci n de problemas 21 22 Pedidos de piezas servicio P g posterior SAVE THIS MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL PARA FUT...

Страница 2: ...de combustible M Ground terminal terminal de conexi n a tierra N Fuel valve v lvula de combustible O AC circuit breakers disyuntors de circuito de CA P Handle mango Q Wheel rueda R Muffler silenciador...

Страница 3: ...in pasador del enganche Fig 6 A Handle mango B Handle release pin conjunto de pasador de afloje de mango D B A E A B C A Socket wrench llave de casquillo B Adjustable wrench llave ajustable Fig 2 1 3...

Страница 4: ...mango del arrancador retr ctil A Knob perilla B Air filter cover tapa del filtro de aire C Filter element elemento de filtro D Air filter unit unidad del filtro de aire A B C D A Oil cap dipstick tap...

Страница 5: ...Carburetor drain screw tornillo de drenaje del carburador Fig 21 B A A Fuel line conducto de combustible B Fuel filter filtro de combustible A B B A A A Fuel valve v lvula de combustible B Hose barb...

Страница 6: ...the nut and tighten the nut fully Connect the other end of the wire securely to a suitable ground source that is in contact with the soil for a minimum distance of 8 ft The National Electric Code con...

Страница 7: ...onfined space building nearopenwindows orinotherunventilatedspace where dangerous carbon monoxide fumes can collect Carbon monoxide a colorless odorless and extremely dangerous gas can cause unconscio...

Страница 8: ...ar hazardous material Do not operate generator at a gas or natural gas filling station Do not touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury Do n...

Страница 9: ...ntended to explain the levels of risk associated with this product SYMBOL SIGNAL MEANING DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indi...

Страница 10: ...the generator If any of the labels come off the unit or become hard to read contact customer service or a qualified service center for replacement You WILL be KILLED or SERIOUSLY HURT if you do not f...

Страница 11: ...NGINE LUBRICANT WARNING You must add lubricant before first op erating the generator Always check the lubricant level before each operation The lubricant level should always register between the hatch...

Страница 12: ...re 12 Wire 14 Wire 16 Wire 2 5 300 600 1000 ft 600 ft 375 ft 250 ft 5 600 1200 500 ft 300 ft 200 ft 125 ft 7 5 900 1800 350 ft 200 ft 125 ft 100 ft 10 1200 2400 250 ft 150 ft 100 ft 50 ft 15 1800 3600...

Страница 13: ...at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 ELECTRICAL POWER MANAGEMENT To prolong the li...

Страница 14: ...d CO levels are safe the generator can be restarted even if the light is still flashing CHOKE LEVER The choke lever is used when starting the engine FUEL TANK The fuel tank has a capacity of 4 gallons...

Страница 15: ...product with damaged or missing parts could result in serious personal injury WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such al...

Страница 16: ...up in these areas Us ing a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These openings can pull in ge...

Страница 17: ...the unit by rolling it on its wheels CHECKING ADDING LUBRICANT See Figure 7 NOTICE Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure NOT...

Страница 18: ...smoke and stay away from open flames and sparks Failure to follow these instructions could result in a fire and cause serious personal injury NOTE Always use unleaded gasoline with a pump octane rati...

Страница 19: ...he generator Water en tering the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator To clean the unit Use a soft bristle brush and or vacuu...

Страница 20: ...anying engine manual if applicable Measure plug gap The correct gap is 0 028 0 031 in 0 7 0 8 mm To widen gap if necessary carefully bend the ground top electrode To lessen gap gently tap ground elect...

Страница 21: ...L FILTER See Figure 21 Occasionally the fuel filter may become clogged and need to be replaced To purchase a replacement fuel filter contact customer service or a qualified service center NOTE Fuel ta...

Страница 22: ...ently when generator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated...

Страница 23: ...filled before unit will start Check engine lubricant level and fill if necessary Turn fuel valve ON Replace spark plug Move choke lever to START position Drain fuel and carburetor Refuel with fresh g...

Страница 24: ...a different brand of gasoline making sure that the octane rating is 86 or higher If problem continues contact a qualified service center If problem persists after trying the above solutions contact c...

Страница 25: ...NOTES...

Страница 26: ...rra a un ngulo de a lo sumo 45 Si aun as la jabalina se encuentra con el estrato rocoso se la puede enterrar en una trinchera de al menos 75 cm 30 pulg de profundidad En cualquier caso el extremo supe...

Страница 27: ...e un edificio a menos que el generador y el interruptor de transferencia se hayan instalado correctamente y que un electricista calificado haya verificado la salida de energ a el ctrica La conexi n de...

Страница 28: ...un electricista calificado debe instalar el generador que debe conectarse a un interruptor de transferencia como un sistema derivado independiente de conformidad con el Reglamento Nacional de Electric...

Страница 29: ...lido tales como un aparato de televisi n Tambi n podr a resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones por ejemplo con una computadora Tambi n podria resultar nec...

Страница 30: ...Con el funcionamiento del generador se emite mon xido de carbono un gas t xico incoloro e inodoro Si se inhala mon xido de carbono puede causarse n usea desmayo o la muerte Fuego Explosi n El combust...

Страница 31: ...das No exponga la unidad a la lluvia ni la use en lugares h medos Usar un generador en el interior PUEDE MARTARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un...

Страница 32: ...todos los laterales de este producto incluida la parte superior Aguarde al menos 30 minutos para el equipo se enfr e antes de guardarlo El calor generado por el silenciador y los gases de escape pued...

Страница 33: ...otencia necesaria en vatios para arrancar los motores el ctricos de C digo G no obstante si un motor el ctrico no arranca o no alcanza la velocidad de funcionamiento apague el dispositivo o herramient...

Страница 34: ...e en este manual 2 Enchufe y active la primera carga preferiblemente la m xima carga que tenga 3 Deje que se estabilice la salida del generador el motor marcha uniformementeyeldispositivoacopladofunci...

Страница 35: ...r o TANQUE DE COMBUSTIBLE El tanque de combustible tiene una capacidad de 15 14 l 4 gal V LVULA DE COMBUSTIBLE El flujo de combustible del tanque de combustible al motor se activa y desactiva con la v...

Страница 36: ...eza Usar este producto con partes da adas o faltantes puede causar lesiones serias al operador ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cua...

Страница 37: ...e oler los gases de escape del generador est respirando CO Pero incluso si no puede oler los gases de escape es posible que est respirando CO Nunca use un generador dentro de su hogar garaje s tano ni...

Страница 38: ...a un electricista calificado a un inspector de instalaciones el ctricas o a la agencia local con jurisdicci n En algunas reas se deben registrar los generadores en las respectivas compa as de servicio...

Страница 39: ...la tapa lentamente ADVERTENCIA Lagasolinaylosvaporesdelamismasonextremadamente inflamables y explosivos Para evitar lesiones y da os f sicos serios maneje con cuidado la gasolina Mant ngala lejos de...

Страница 40: ...la parte superior Aguarde al menos 30 minutos para el equipo se enfr e antes de guardarlo El calor generado por el silenciador y los gases de escape puede ser suficiente para causar quemaduras graves...

Страница 41: ...iar el generador El agua que entra al sistema de combustible u otras partes internas puede causar problemas que acortan la vida de servicio del generador Para limpiar la unidad Con un cepillo de cerda...

Страница 42: ...liminar dichos dep sitos para restablecer el desempe o original Recomendamos enf ticamente que este servicio lo realicen nicamente t cnicos de servicio calificados PARACHISPAS Vea la figura 17 AVISO E...

Страница 43: ...Gire la v lvula de combustible hasta la posici n OFF APAGADO Empuje la perilla de la v lvula del combustible a trav s del alojamiento del generador y ll vela con cuidado hacia la abajo para poder acce...

Страница 44: ...to debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento de acue...

Страница 45: ...tica que apagar elmotorcuandonosemantieneelnivel espec ficodelubricante Sielniveldellubricante del motor es bajo debe llenarse antes de que la unidad arranque Revise el nivel del lubricante del motor...

Страница 46: ...ito de AC Pruebe con un dispositivo diferente El generador produce un ruido como de cascabeleo o explosiones Un leve ruido ocasional de cascabeleo o explosiones si la carga es pesada no debe ser causa...

Страница 47: ...NOTAS...

Страница 48: ...etters at the end These letters designate manufacturing information and should be provided when calling for service SERVICIO Para obtener piezas o servicio comun quese con el centro de servicio Para a...

Отзывы: