SET UP & USE

Horizontal Louvers

Control Panel

1.    

POWER:

 Turn on the unit by rotating the MODE dial to the desired COOLING or FAN 

setting. Turn the dial to OFF at any time to shut OFF the unit. 

2.    

COOLING MODE:

automatically go to high and circulate the cool air throughout the room. The fan will 
operate on low in LO COOL mode.

3.    

THERMOSTAT: 

Turn the TEMP dial to set the desired temperature setting 1-7. For 

4.  

FAN MODE:

 For fan only modes, choose either HI FAN or LO FAN. The thermostat will 

not operate when in fan mode.

NOTE:  

To minimize wear and tear on the air conditioner, always wait at least 3 minutes 
before changing modes. This will help prevent the compressor from overheating 
and the circuit breaker from tripping.

PARTS & FEATURES 

TEMPERATURE

min

cool

max

cool

COOLING

1

4

5

6

7

2

3

lo

fan

lo

cool

hi

cool

hi

fan

OFF

Filter

Mode Dial

Содержание BD05MWT

Страница 1: ...DECKER purchase go to www blackanddecker com instantanswers If you can t find the answer or do not have access to the Internet call 844 299 0879 from 10 30 a m to 6 30 p m EST Mon Fri to speak with a...

Страница 2: ...386 mm 5 00 Wind TOP SIDE ALWAYS UP BWAM5MW6 000 BTU dow Air Conditioner...

Страница 3: ...ner 9 12 Parts Features 14 CLEANING CARE Air Filter Cleaning 15 Winter Storage 15 TROUBLESHOOTING WARRANTY Before You Call For Service 16 Customer Service 16 Troubleshooting 17 Limited Warranty 18 Tha...

Страница 4: ...h plug connector or if the unit malfunctions or is damaged in any manner Contact an authorized service technician for examination repairs or adjustments 4 DO NOT USE AN ADAPTER OR AN EXTENSION CORD 5...

Страница 5: ...at is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the cord or plug is necessary do not connect the equipment grounding conductor to a live ter...

Страница 6: ...all power to the air 4 5 Press the RESET button for use You will hear a click and the A C is ready for use NOTES The RESET button must be engaged for proper use Do not use the power supply cord as an...

Страница 7: ...unit and unplug from the power supply immediately Always use the switch on the control panel to start or shut off the unit Do not operate your air conditioner in a wet room such as a bathroom or laun...

Страница 8: ...ot under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner on front and rear coils SUGGESTED TOOLS FOR INSTALLA...

Страница 9: ...ooden w ndows For V nyl C ad w ndows on some models 10 3 4 1 12 Weather stripping 5 Packaging Top Rail Page 9 3 4 or 1 Screws 7 2 Lock Frame 2 Sash Lock 1 W 3 8 Screws 4 Top Rail 1 Packaging Fig A Top...

Страница 10: ...leave enough space to slip the top and bottom of the frame into the rails on the cabinet C Once the panel has been installed on the side of the cabinet make sure it sits securely inside the frame chan...

Страница 11: ...cking screws through frame holes into window sash Fig 8B FOR VINYL CLAD WINDOWS Drive 1 2 12 7 mm locking screws through the frame lock and into the window sash Fig 8B NOTE Before driving the screws u...

Страница 12: ...al from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock With 2 people keeping a rm grip on air conditioner raise sash and carefully remove Be carefull...

Страница 13: ...ool to fan and back to cool This prevents compressor from overheating possible circuit breaker tripping To begin operating the air conditioner follow these steps 1 Set the thermostat to the highest nu...

Страница 14: ...COOL mode 3 THERMOSTAT Turn the TEMP dial to set the desired temperature setting 1 7 For 4 FAN MODE For fan only modes choose either HI FAN or LO FAN The thermostat will not operate when in fan mode N...

Страница 15: ...iquid dishwashing detergent Rinse thoroughly and wipe dry cabinet front water in or around the controls may cause damage to the air conditioner Plug in air conditioner WINTER STORAGE If you plan to st...

Страница 16: ...ts safely in accordance with an industry recognized assessment Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other s...

Страница 17: ...es blinds furniture etc restricts air distribution Clear blockage in front of unit An open doors windows or register may allow cold air to escape Close any doors winows or registers The room may be to...

Страница 18: ...ice calls to repair or replace the house fuse reset a circuit breaker or correct the wiring in the house 4 Service calls required due to improper installation REPAIR OR REPLACEMENT AS PROVIDED UNDER T...

Страница 19: ...ENGLISH Page 19...

Страница 20: ...trademarks of The Black Decker Corporation used under license All rights reserved Product in this box may differ slightly from that pictured Does not affect function Not all accessories shown in photo...

Отзывы: