--6--

4) The tester will power on immediately and indicate a test 

in progress by displaying the TEST icon. It will be followed

within 2 seconds by a wire map display of the results, plus 

a PASS icon and a beep if it passed the set shield criteria 

and T568A/B standard. The ID number for the remote will

also be displayed.

5) Disconnect cable after test. The test repeats every 5 seconds.

Application Hints:

The jumper cables must be short compared 

to the cable run for accurate split pair indication – no more than

10% of the total run length.

To Test Coax 

(tester off or in TEST/PRE-TEST mode)

1) Plug  RJ45 to F coax adapters into the remote and main units.

2) Attach cable to be tested to F connectors.

3) The tester will power on if it senses the cable. If not, the

cable is open. The coax adapter is connected to the 1-2 pair

and will display “12” on the second line if good and flashing

“xx” if shorted.

4) Length may be measured as well by setting length constant

and selecting 1-2 pair.

To Place Tone on a Cable 

1) Turn on unit by pressing any button. If not in tone mode,

press MODE until TONE is displayed, than press SEL button.

2) Press SEL until desired tone is selected. The up/down arrow

keys select the pin or pair(s) to carry the tone.

3) Connect cable to be traced to main unit. For best signal, do

not connect remote. Due to the shielding effect of twisted

pairs, the strongest signal is obtained by having one wire of 

a pair carry tone. Selecting a single pin instead of a pair will

do this.

4) To turn tone off, press the MODE button until TURN OFF 

is displayed, then the SEL button. The tone will turn off 

automatically after about 2.4 hours.

--5--

Cable Testing

To Test a Patch Cable 

(see “Caution!” on page 1 about cables

with bad plugs) 

1) Plug one end of patch cable into main unit.

2) Plug other end of cable into remote unit.

3) The tester will power on immediately and will indicate a test

in progress by displaying the TEST icon. It will be followed by
map results plus a PASS icon and a beep, if it passed both
the T568A/B standard and the configured shield criteria.

4) Disconnect patch cable after test. The test repeats every 

5 seconds.

To Test Cable from One End 

This can be done immediately after termination of one end of
the cable, because no connector or remote is required at the
other end of the cable. Attach a remote after the pre-test and
you are ready for a full test when the other end is terminated.

1) Attach one end of supplied one-foot jumper to main unit and

the other end to the wall plate or patch panel jack.

2) Turn on unit by pressing any button. If not in pre-test mode,

press MODE until TEST/PRE-TEST is displayed, than press 
SEL button.

3) Results should appear within 5 seconds. Pressing SEL button

starts a new test immediately.

4) Disconnect cable after test. The test repeats every 5 seconds.

Application Hints:

The jumper cables must be short compared 

to the cable run for accurate open and split pair indication,
either no more than 10% of the total run length or 3 feet,
whichever is less. Cable being tested must be at least 4 feet
long for pre-test to work properly.

To Test Installed Cable

(office jack to patch panel with remote)

1) Remove remote unit from main unit by sliding remote towards

top of the main unit.

2) Attach one end of supplied one-foot patch cable to the

remote and other end to the wall jack.

3) Attach one end of the second supplied one-foot patch cable

to the main unit and other end to the patch panel jack.

--4--

complement of the signal on the other pin of the pair, yielding 
a nominal 10 volts peak-to-peak across the pair. The SEL button
selects one of the four tone sounds provided. The up and down
arrows scroll through the pairs and pins that have signal on
them. All pins not being driven are held at tester ground.

Setup

– The setup mode is provided to set user-selectable

options. The beep-on-pass can be turned on or off (default is on).
The pass criteria can be set for shielded or unshielded cables
(default is unshielded). The length and length constant can be set
for meters or feet (default is feet). If the length units are changed,
the tester converts the currently set length constant to the new
units on exit of setup. The up and down arrow buttons scroll
through the settable options. The SEL button changes the current
setting to the other option. On exit, the mode screen first offers
to return to the last mode used before entering setup.

The LanTest Pro monitors for voltage being present on the RJ
jack when off, in TEST/PRE-TEST mode or in LENGTH mode.
The “VOLTAGE!!” message appears on the screen and the beeper
sounds continuously until the voltage is removed.

INSTRUCTIONS FOR USE

LanTest Pro powers off automatically after 5 minutes of 
continuously testing a cable when auto-on powered up the
tester. Disconnecting the cable restores normal function. Most
power-on modes will timeout in about 18 minutes, except for
tone, which is about 2.4 hours. Be sure to install a battery if
using for the first time—see battery installation.

PASS FAIL CAL SETUP TEST

01234567klmnorst

abcdefhi23456789

1 2 3 4 5 6 7 8 S ID

Adjusting length constant

Cable has shorts or splits          Setup mode

Cable passed T568A/B                                 Test in progress

Beeper off

Main unit 
pin numbers

Alphanumeric characters

Battery low

ID number icon 

(remote ID displayed below it)

LanTest Pro LCD Display