3. Setup and Installation

3.1 Installation

Set switches to match the required configurations as described in 

Sections 3.2

through

3.5

. The cabling between each device and the Time-Division Multiplexor

must be terminated with male connectors. Character length and stop-bit reduction
only apply to channel 1 when it is selected for asynchronous operation.

3.2 Character Length

SW1 positions 1 and 2 select the character length. The character length includes
the start, stop, and any parity bits. 10-bit length is 1 start bit, 8 data bits, and 1 stop
bit. 

Figure 3-1

outlines all the available character bit lengths available.

3.3 Stop-Bit Reduction

SW1 position 3 selects the percentage of stop-bit reduction to occur when the sync
rate is faster than the async rate. Setting SW1 position 3 to ON will select 25% stop-
bit reduction. Setting SW1 position 3 to OFF will select 12.5% stop-bit reduction.

3.4 Channel 1 Sync/Async

SW1 position 5 selects channel 1 as a sync or async channel. This selection must be
the same on both ends of the circuit for the units to operate correctly. Setting SW1
position 5 to ON will select asynchronous operation on channel 1. Setting SW1
position 5 to OFF will select synchronous operation on channel 1.

3.5 Equipment Grounding

SW1 position 6 connects Pin #1 (Chassis Ground) to Pin #7 (Signal Ground).

3.6 Factory Straps

SW1 position 4 is not used. It must be in the OFF position. Jumpers JP1 through
JP3 must be installed for proper operation.

Содержание Time-Division Multiplexor

Страница 1: ...ORMATION Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box...

Страница 2: ...e equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take...

Страница 3: ...l aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en...

Страница 4: ...existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuida...

Страница 5: ...4 TIME DIVISION MULTIPLEXOR TRADEMARKS UL is a registered trademark of Underwriters Laboratories Incorporated The trademarks mentioned in this manual are the sole property of their owners...

Страница 6: ...pecifications 6 2 Introduction 7 3 Setup and Installation 8 3 1 Installation 8 3 2 Character Length 8 3 3 Stop Bit Reduction 8 3 4 Channel 1 Sync Async 8 3 5 Equipment Grounding 8 3 6 Factory Straps 8...

Страница 7: ...s Async 600 bps to 19 2 kbps or sync up to 19 2 kbps with 38 4 kbps composite Data Interface EIA RS 232C Connectors 3 DB25 female Enclosure Aluminum Approvals FCC Class A UL CSA Operating Temperature...

Страница 8: ...composite channel Power is provided by an external transformer connected through J1 Power on the rear of the mutliplexor The external power transformer is UL and CSA approved Front panel LEDs include...

Страница 9: ...e 3 3 Stop Bit Reduction SW1 position 3 selects the percentage of stop bit reduction to occur when the sync rate is faster than the async rate Setting SW1 position 3 to ON will select 25 stop bit redu...

Страница 10: ...UST BE IN Character Length ON OFF 25 Stop Bit Reduction ON 12 5 Stop Bit Reduction OFF Factory Test MUST BE OFF Chan 1 Async ON Chan 1 Sync OFF Signal Ground Connected to Chassis Ground ON J2 J3 J4 Co...

Страница 11: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1999 Black Box Corporation All rights reserved...

Отзывы: