background image

Appendix C: Board Diagram

13

Appendix C: Board Diagram

The base unit is drawn below, up to the 8th
connector. The remainder of the board contains 
no items of significant interest.

You may need to remove the power unit in order

to change the input voltage for the switch. (see
section 3.2). A jumper within the case governs the
voltage, and may be adjusted to the proper setting
(115 or 230 V) within a matter of minutes. 

You must first unplug the unit and remove the

power cord. Then remove the top and rackmount
sides of the base unit by removing the 12 slot screws
on the sides. Also remove the pair of large screws
directly underneath the power unit.

Then, pull the power connector out of its socket

(at position P1A) and carefully remove the power
unit from the body of the unit.

You must now remove the cover of the power unit

by removing the four slotted case screws. At one
end of the power unit lies the transformer, at the
other lies the jumper bank. 

You’ll see a white jumper with a black loop of 

wire connected to it. The bank beneath has two
positions, marked 115 V and 230 V. By gripping the
loop of wire, you may remove the jumper from the
bank. Set the jumper to the voltage setting you
desire.

You may now replace the cover of the power unit

and return it to the case. 

LEDS

CONNECTORS

ON / OFF

SWITCH

Jx

P1A

P1B

P2

Содержание SW056A

Страница 1: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2000 Black Box Corporation All rights reserved...

Страница 2: ...ed in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures ma...

Страница 3: ...Bank 2 5 3 2 Powering and Cabling the Switch 6 4 OPERATION 7 4 1 Front Panel Indicators 7 4 1 1 Status LEDs 7 4 1 2 Section and Active Port LEDs 7 4 2 Selecting a Port 7 4 3 Requesting Broadcast Mode...

Страница 4: ...Power and Broadcast Speed 200 bps to 19 2 Kbps Protocol Asynchronous Leads Switched TD RD RTS CTS Connectors 17 DB25 female Power 115 230 VAC 60 50 Hz autosensing Size 3 5 H x 17 3 W x 9 D 8 9 x 43 9...

Страница 5: ...e switch the ability to distinguish between switching instructions and the lookalikes that sometimes occur in data files With code repetition enabled the switch will only react to instructions that ha...

Страница 6: ...rt below also on the bottom of the case gives the arrangement of the first four DIP switches Prefix Codes Switch and Position Required 1 2 3 4 1 1 0 0 0 2 0 1 0 0 4 0 0 1 0 8 0 0 0 1 Broadcast Switch...

Страница 7: ...u switch the COS 16 on you reset the COS and close all ports Control Switch and Setting Character Code 1 2 3 4 5 6 7 Ctrl NUL ON ON ON ON ON ON ON Ctrl A SOH OFF ON ON ON ON ON ON Ctrl B STX ON OFF ON...

Страница 8: ...orts 17 through 32 is selected Section LED 2 will light Section LED 3 corresponds with the third bank of ports Ports 33 through 48 and Section LED 4 corresponds with the fourth bank of ports Banks 49...

Страница 9: ...e selected port including the next prefix code If your switch were configured for a prefix character of Ctrl V required four repetitions of the prefix code and you wished to connect to port 14 you wou...

Страница 10: ...1 DC3 0 0 1 1 0 1 1 DC4 1 1 0 1 0 1 1 NAK 0 1 0 1 0 1 1 SYN 1 0 0 1 0 1 1 ETB 0 0 0 1 0 1 1 CAN 1 1 1 0 0 1 1 EM 0 1 1 0 0 1 1 SUB 1 0 1 0 0 1 1 ESC 0 0 1 0 0 1 1 FS 1 1 0 0 0 1 1 GS 0 1 0 0 0 1 1 RS...

Страница 11: ...4 1 1 0 1 0 0 1 5 0 1 0 1 0 0 1 6 1 0 0 1 0 0 1 7 0 0 0 1 0 0 1 8 1 1 1 0 0 0 1 9 0 1 1 0 0 0 1 1 0 1 0 0 0 1 0 0 1 0 1 0 1 1 1 0 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 0 0 1 0 0 0 0 0 0 1 1 1 1 1 1 1 0 A 0 1...

Страница 12: ...1 1 0 0 a 0 1 1 1 1 0 0 b 1 0 1 1 1 0 0 c 0 0 1 1 1 0 0 d 1 1 0 1 1 0 0 e 0 1 0 1 1 0 0 f 1 0 0 1 1 0 0 g 0 0 0 1 1 0 0 h 1 1 1 0 1 0 0 i 0 1 1 0 1 0 0 j 1 0 1 0 1 0 0 k 0 0 1 0 1 0 0 l 1 1 0 0 1 0 0...

Страница 13: ...our devices Use the figures below to choose the proper cable for your site 1 2 15 3 17 4 5 7 6 20 1 2 3 4 5 7 6 8 GROUND DATA IN DATA OUT RTS IN CTS IN GROUND DSR OUT DCD OUT INPUT 1 16 CONTROL MODEM...

Страница 14: ...ews on the sides Also remove the pair of large screws directly underneath the power unit Then pull the power connector out of its socket at position P1A and carefully remove the power unit from the bo...

Страница 15: ...on the add on so the P1 and P2 connectors are accessible on the master unit 4 Plug the add on module s power cable at P1A into the master unit s P1B connector 5 Plug the add on module s ribbon cable a...

Страница 16: ...NOTES...

Страница 17: ...NOTES...

Страница 18: ...46 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION OCTOBER 2000 SW056A SW057A RM056 Code Operate...

Отзывы: