background image

ServSwitch Wizard Extenders

®

NETWORK SERVICES

®

Order 

toll-free 

in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 

877-877-BBOX 

FREE technical support, 24 hours a day, 7 days a week: Call 

724-746-5500 

or fax 

724-746-0746 

Mail order: 

Black Box Corporation

, 1000 Park Drive, Lawrence, PA 15055-1018 

Web site: 

www.blackbox.com 

• E-mail: 

[email protected]  

CUSTOMER 

SUPPORT 

INFORMA-

July 2005

ACU5122A
ACU5142A

Содержание ServSwitch ACU5122A

Страница 1: ...o midnight Friday 877 877 BBOX FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMA July 2005 ACU5122A ACU5142A ...

Страница 2: ...ng and exiting configuration mode 16 Password setting 17 Password override 17 Hot plugging and mouse restoration 18 Which restore setting do I use 18 Microsoft and Logitech specific mouse settings 18 Image controls sharpness and brightness 19 Skew adjustment 20 Miscellaneous settings 21 Flash upgrade 22 Stage A Download the upgrade files 22 Stage B Create a startup diskette 22 Stage C Reconfigure ...

Страница 3: ...m a computer system In addition locally connected video monitors keyboard mouse and speakers allow two users to simultaneously view the outputs of the host system and also take control of the system providing it is not being used by the other user A user relinquishes control two seconds after their last key press or mouse movement Two variants of the Multi Screen extenders are available the ACU512...

Страница 4: ...ID EO OUT 1 CPU KVM SW ITCH VID EO W i z a r d E x t e n d e r L O C A L 7 2 4 7 4 6 5 5 0 0 VID EO OUT 4 VID EO OUT 3 VID EO OUT 2 VID EO OUT 1 W i z a r d E x t e n d e r R E M O T E 7 2 4 7 4 6 5 5 0 0 ACU5142A Keyboard mouse audio four video and four serial channels OR VID EO IN 2 VID EO OUT 2 VID EO OUT 1 OUT CPU KVM SW ITCH VID EO 1 W i z a r d E x t e n d e r L O C A L 7 2 4 7 4 6 5 5 0 0 V...

Страница 5: ...o local keyboard and mouse Connection to local speakers Connections for video inputs 2 3 and 4 from computer Connections to local video monitors 1 2 3 and 4 VID EO OUT 4 VID EO OUT 3 VID EO OUT 2 VID EO OUT 1 W i z a r d E x t e n d e r R E M O T E 7 2 4 7 4 6 5 5 0 0 Connections for microphone and speakers REMOTE module ACU5142A model pictured Power supply connection Switch bank to determine cert...

Страница 6: ... the REMOTE unit LOCAL Switch 4 OFF Normal operation ON Suspend operation and reset the LOCAL module Use this setting momentarily to produce the same effect as removing and restoring power if incorrect operation has occurred Return the switch to the OFF position to allow normal operation to continue Installation The installation of the Wizard extenders is straightforward and can best be achieved i...

Страница 7: ...e REMOTE module that the next key to be pressed is a special configuration command for the module and is not to be passed to the computer system 2 OFF 3 OFF Hotkeys CTRL and SHIFT 2 OFF 3 ON Hotkeys ALT and SHIFT 2 ON 3 OFF Hotkeys CTRL and ALT 2 ON 3 ON Hotkeys disabled REMOTE Switch 4 This switch is reserved for future use Note When shipped all switches are set in the OFF positions and this will...

Страница 8: ...er cables where possible Rack mount Note The module switches are not accessible once it is inserted into the rack therefore check all settings before insertion 1 Place the supplied rack plate onto the front of the module and secure it with the countersunk screws 2 Orient the module on its side so that its labelled face is the correct way up and the securing plate is facing away from the rack 3 Sli...

Страница 9: ...t the end of the LOCAL module 2 At the other end of the multi cable attach the keyboard mouse primary video channel microphone and speaker connectors to the appropriate sockets at the rear of the computer system On most systems the appropriate ports should be labelled and colour coded in a similar way to the cable connectors Monitor video Blue Keyboard Purple Mouse or Mid green Speaker or SPK Ligh...

Страница 10: ...Connect the other end of each serial link cable to the appropriate serial port of the computer system Additional video channel inputs The ACU5122A model provides a second video channel and the ACU5142A model provides a further three channels in addition to the main video channel that enters via the multi cable connection 1 Use the supplied video connection cable s to make a link between the additi...

Страница 11: ...the REMOTE module labelled TO LOCAL 1 to TO LOCAL 4 Power connection optional on ACU5122A model The ACU5122A and ACU5142A LOCAL modules both have power input sockets However only the ACU5142A model has a mandatory requirement for power input from a supplied adapter The ACU5122A LOCAL module requires a separate power input only when the keyboard connection to the host system is not used Separate po...

Страница 12: ...OCAL module matches the input to this socket OFF microphone ON stereo line input 2 Connect the speaker plug to the socket labelled Connections at the REMOTE module Keyboard and mouse connections 1 Connect the keyboard lead to the purple mini DIN socket labelled on the REMOTE module 2 Connect the keyboard lead to the green mini DIN socket labelled on the REMOTE module Note When the REMOTE module is...

Страница 13: ...wisted pair connections cables must be of equal lengths SERIAL 4 SERIAL 3 SERIAL 2 SERIAL 1 POW ER TO 4 LOCAL TO 3 LOCAL TO LOCAL 2 TO LOCAL 1 INDOOR USE ONLY REMOTE Connections to serial devices two outputs available on ACU5122A model Twisted pair link connections The links between the LOCAL and REMOTE modules are made using between one and four twisted pair cables specified to Category 5 or high...

Страница 14: ...TE module labelled POWER SERIAL 2 SERIAL 1 POW ER 2 TO LOCAL 1 INDOOR USE ONLY Power supply connection REMOTE IEC power connector 2 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply Connect the other end of the power lead to a nearby mains socket ...

Страница 15: ... output from the host system Control of the host system is arbitrated by the Wizard modules on a first come first served basis In the idle state control is available to both users and their keyboard indicators both show the current Num Lock etc conditions of the host system At the moment that a key is pressed or a mouse is moved the keyboard and mouse of the other user are temporarily locked out t...

Страница 16: ...the three keyboard indicators will begin alternately flashing between the Num Lock and Scroll Lock and Caps Lock This sequence indicates that a password is required To unlock the system 1 Enter the correct password and press Note Passwords are NOT case sensitive Note If an invalid password has been entered and the keyboard indicators are not flashing as described above press to clear the incorrect...

Страница 17: ... computer tasks you can change them for another combination using switches 2 and 3 on the REMOTE module 2 OFF 3 OFF Hotkeys and default setting 2 OFF 3 ON Hotkeys and 2 ON 3 OFF Hotkeys and 2 ON 3 ON Hotkeys disabled Entering using and exiting configuration mode To enter and use configuration mode 1 Simultaneously press the currently configured hotkeys by default and along with The three keyboard ...

Страница 18: ...d unlocking the system section in the Installation and operation chapter Password override This mode allows you to override the password that has been set at the REMOTE module and place it into configuration mode so that a new one may be set This feature is particularly useful when passwords have been lost or forgotten To override the REMOTE password 1 Remove power from the REMOTE module 2 With po...

Страница 19: ... that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot plugging the modules or afterwards using only keyboard control access the Windows Control Panel and select either the Mouse option on Windows NT 2000 and XP or the System option on Windows 95 98 ME Look for the name of the driver which will usually include the words PS 2 or Intellimouse To restore mous...

Страница 20: ...nfiguration mode The three keyboard indicators Num Lock Caps Lock and Scroll Lock will now begin to flash in sequence The speed of the sequence indicates the level of the sharpness adjustment currently applied the slower the rate the lower the level of sharpness being applied 2 While viewing the displayed high contrast screen image use the following keys to adjust the controls High contrast black ...

Страница 21: ...horizontally Skew affects the horizontal placement of the colours and using this pattern it is much easier to discover which if any colours are being adversely affected by the twisted pair cable run 3 Simultaneously press the hotkeys by default and along with to enter configuration mode The three keyboard indicators Num Lock Caps Lock and Scroll Lock will now begin to flash in sequence 4 As approp...

Страница 22: ...running an application that can display typed keys as screen characters e g a word processor or Windows Notepad The current firmware version will be written to the application in the form of the letter V followed by three numbers for example V201 means version 2 01 Reset all configuration options to default states Returns all user configurable options to the settings that are installed at manufact...

Страница 23: ...e X2GDLxxx HEX X2SLLxxx HEX X2STLxxx HEX these are the firmware files for the LOCAL module M2GDRxxx HEX M2SLRxxx HEX M2STRxxx HEX S2GDRxxx HEX S2SLRxxx HEX S2STRxxx HEX these are the firmware files for the REMOTE module Where xxx is the upgrade version number Now please follow Stage B Stage B Create a startup diskette For this stage you will need a 31 2 floppy diskette that is either blank or has ...

Страница 24: ...t of the computer Connect the other end of the cable to the keyboard port of the REMOTE module This is the only connection required 3 On the REMOTE module change switch 1 to the ON position 4 Attach the power supply unit to the POWER input of the REMOTE module and connect the mains lead to a nearby wall socket 5 Switch on the computer The upgrade process will start automatically and confirmation w...

Страница 25: ...les Ensure that all of the link cables are of the same length and have the same twist characteristics it is not possible to adjust only one video channel they are all adjusted together If the sharpness control is set too high the monitor may not be able to display a picture Try reinstating the factory default sharpness settings Please refer to the Image controls sharpness and brightness section in...

Страница 26: ...tal ampere rating of all the devices plugged into the wall outlet does not exceed the wall outlet s ampere rating Do not attempt to service the Wizard modules yourself The Wizard modules and power supplies can get warm in operation do not situate them in an enclosed space without any ventilation The Wizard modules do not provide ground isolation and should not be used for any applications that req...

Страница 27: ...he equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance with the manufactur...

Страница 28: ...Repairs to certified equipment should be made by an authorized Canadian maintenance facility in this case your supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power u...

Страница 29: ...por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el aparato 12 Precaución debe ser tomada...

Страница 30: ...8 800 35 201 888 808 tuki blackbox fi France www blackbox fr 33 1 45 606 717 33 1 45 606 747 tech blackbox fr Germany www black box de 49 811 5541 110 49 811 5541 499 techsupp black box de Ireland www blackbox co uk 353 1 662 2466 353 1 662 2477 techhelp blackbox co uk Italy www blackbox it 39 02 27 404 700 39 02 27 400 219 supporto tecnico blackbox it Netherlands www blackbox nl 31 30 241 7799 31...

Страница 31: ...rademarks are acknowledged Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 United States of America Tel 1 724 746 5500 Fax 1 724 746 0746 Black Box Network Services UK Ltd 464 Basingstoke Road Reading Berkshire RG2 0BG United Kingdom Tel 44 0 118 965 5100 ...

Страница 32: ... NETWORK SERVICES Copyright 2005 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 ...

Отзывы: