6. CLI Operation 

 
6.1 Command Line Interface 

The Command Line Interface follows a set/get syntax similar to SNMP.   

All configuration is performed from the CLI.  It can be accessed via 
Telnet Client, Serial Port and Dial-up Modem, using a Terminal client.  
Below is a listing of all interface commands and syntax.  

 

CLI Interface using Telnet Client

 

 

 

CHAPTER 7: Advanced Features

 

19 

6.3 Device Commands 

 

get device name 

 

set device name <name> 

Each ServPower Omni can have 

a name assigned.  20 

characters Max, no spaces. 

 

get current 

Returns the current draw for 

each Main in Amperes 

 

set password <oldpass> 
<newpass> <confirm> 

Sets the password for the 

current user 

get cycle 

 

set cycle <n> 

The cycle time is the length of 

the reboot or power on. In 

seconds 0 - 99 

get delay 

 

set delay <n> 

The delay time is the pause 

between power up of each 

outlet when multiple outlets 

are powered on. 0 - 99 

 

logout 

Ends the session 

 

The following commands require administrative rights

 

 

get current alarm 

 

set main <a/b> highalarm 
<nn.n> 

 

set main <a/b> lowalarm <nn.n> 

High and Low alarms are used 

to monitor current conditions 

and send an alert by email or 

SNMP when the high or low 

thresholds are exceeded.  

From 0.1 to 15.0 (20.0 in 20 

amp units) in 0.1 amp 

increments.  Main A and Main 

B are set separately, but 

displayed together with the 

get command. 

 

get console 

Display current console 

configuration 

 

set console timeout <30-
3600/disable> 

Console can be set to 

automatically logout with no 

activity for 30 seconds to 1 hr 

in seconds, or disabled. 

 

set console baudrate <baud>  

2400, 4800, 9600, 19200, 

Содержание ServPower Omni PS730A

Страница 1: ...PS732A M PS733A PS733A M PSE711 PSE712 PSE713 PSE714 PSE721 PSE722 PSE723 PSE724 Order toll free in the U S 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a w...

Страница 2: ...37...

Страница 3: ...protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the use...

Страница 4: ...do de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o...

Страница 5: ...l manera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados...

Страница 6: ...M N15 8 x N15 I S M PS731A 2 x N15 8 x N15 I S L PS731A M 2 x N15 8 x N15 I S M PS732A N20 8 x N15 I S PS732A M N20 8 x N15 I S M PS733A 2 x N20 8 x N15 I S PS733A M 2 x N20 8 x N15 I S M PSE711 C14 8...

Страница 7: ...onger will initiate a password recovery mode Once the reset button is released the user has 30 seconds to log in to the CLI using the username admin and password admin Upon accessing the CLI change th...

Страница 8: ...subnetMask 5 RW DisplayString gateway 6 RW INTEGER Enum webEnable 7 RW Integer32 webPort 8 RW INTEGER Enum sslEnable 9 RW INTEGER Enum telnetEnable 10 RW Integer32 telnetPort 11 RW INTEGER Enum updat...

Страница 9: ...name 128 char max set email password password 128 char max Each user is assigned an email address and email can be turned on or off for that user set user name email email address 64 char max set user...

Страница 10: ...outlet When the ping response returns ServPower Omni will power the off the outlet Off Latch Upon triggering ServPower Omni will power off the assigned outlet and remain so until changed via the web...

Страница 11: ...tor or siren You set any IP address to be periodically pinged When ServPower Omni no longer detects a response from the address the programmed power control function is actuated Up to eight IP address...

Страница 12: ...set for each user This PIN is set using the command line interface and must be 4 to 10 digits long Program a PIN code of 0 to disable a users ability to use DTMF control 7 2 DTMF Call Sequence 1 Dial...

Страница 13: ...ServPower Omni cannot exceed 16 Amps The ServPower Omni models PS733A and PS733A M provide two linecords for connection to 20 Amp 115VAC services The total maximum current load for outlets on any line...

Страница 14: ...rights get users Returns a list of users add user name Adds a new user the new password is automatically created to match the name get user name Returns user name s rights and settings ren user name n...

Страница 15: ...l port or via dial modem Factory Default is 115200 8 n 1 Upon connection press Enter then enter the username and password when prompted Factory Default for both is admin A complete list of valid comma...

Страница 16: ...e ServPower Omni to your local network and apply power The IP address to be assigned to ServPower Omni must be use the same network segment as the computer assigning the address ARP does not work acro...

Страница 17: ...guration 15 WINDOWS 98 AND LATER 1 Access the ServPower Omni CLI and enter the set ipmode arp ping command 2 On a PC open a DOS window Run Command 3 Type the following command arp s IP Address MAC Add...

Страница 18: ...or more details CONTROL The Control panel provides the clickable buttons to cause a change of outlet condition Once one or more outlets are selected click CHAPTER 7 Advanced Features 21 6 3 Outlet Com...

Страница 19: ...r current draw on initial power up of devices Entries of 0 to 99 seconds are valid The Select All and Select None buttons allow selection or de selection of all outlets Refresh provides an update of t...

Страница 20: ...cle n The cycle time is the length of the reboot or power on In seconds 0 99 get delay set delay n The delay time is the pause between power up of each outlet when multiple outlets are powered on 0 99...

Отзывы: