3.3 Connecting the Head Unit to the Control Unit
1. Once the back plate of the head unit and the control unit are securely mounted, run a 4-pair (8-conductor) Belden 9504 cable
(available from Black Box) or equivalent cable between the control unit and head unit.
2. The cable will exit the control unit via one of the push-out holes located on the bottom of the unit, running neatly along the
wall and into the hole drilled through the rear of the head unit. Leave approximately 12" (300 mm) of spare cable at each end
so that you can strip the wires and connect them to the terminal blocks.
3. The cable should be wired as shown in Figure 3-1. The actual colors are not important, but make sure you connect each pair of
wires as shown in the diagram.
4. Wire the head unit as shown in Figure 3-1.
5. To simplify the wiring, you can remove the 2-part connectors from the boards.
6. Strip approximately
1
⁄
4
" (6 mm) of sheath from each cable, braid the end, and insert into terminal blocks, checking that all wires
are securely fastened.
7. Repeat Steps 4–6 at the control unit.
Figure 3-1. Connecting the control unit to the head unit.