background image

6

Ordering Information

ITEM

CODE

16-Port Managed MicroRACK...................................RM260

Choose your power supply card: 

NOTE: RM260 comes with (1) AC power supply front and back card.

AC Power Supply (90 to 260 VAC)

for Redundancy........................................................PS466A

DC Power Supply (-48 VDC)...............................PS466A-DC

Choose the interface cards for your application…

G.703/E1 Fiber Line Driver Cards 

Multimode with ST

®

Connectors ..............ME400C-ST

Single-Mode with FC Connectors ............ME401C-FC

with SC Connectors ..........ME401C-SC

2-Wire Short-Range DSL Line Driver Cards

mDSL

V.24 (DB25 F)..............................................ME0004C-V24
V.35 (M/34 F) ..............................................ME0004C-V35
X.21 (DB15 F) .............................................ME0004C-X21
10BASE-T (RJ-45)..................................ME0004C-10BT
G.703/G.704 (Dual BNC or RJ-45).......ME0004C-G703
RS-530 (DB25 F) ...................................ME0004C-RS530

hDSL

V.24/V.35 (DB25 F).....................................ME0003C-V24
V.35 (M/34 F) ..............................................ME0003C-V35
X.21 (DB15 F) .............................................ME0003C-X21
10BASE-T (RJ-45)..................................ME0003C-10BT
G.703/G.704 (Dual BNC or RJ-45).......ME0003C-G703
RS-530 (DB25 F) ...................................ME0003C-RS530

ITEM

CODE

2-Wire idSL Line Drivers

V.24 (DB25 F)..................................................ME0001C-V24

V.35 (M/34 F) ..................................................ME0001C-V35
X.21 (DB15 F)..................................................ME0001C-X21
10BASE-T (RJ-45)......................................ME0001C-10BT
G.703/G.704 (Dual BNC or RJ-45)...........ME0001C-G703
RS-530 (DB25 F) .......................................ME0001C-RS530

Micro T1 CSU/DSU Cards

10BASE-T (RJ-45) ........................................MT911C-10BT
V.35 (M/34 F) .......................................................MT911C-35
RS-530 (DB25 F)...............................................MT911C-530

To protect unpopulated rack ports, order…

Blank Panels

Front Panel 

1", 1-Slot Wide.......................O1OZ20885
4", 4-Slot Wide.......................O1OZ20887

Rear Panel 

1", 1-Slot Wide.......................O1OZ20888
4", 4-Slot Wide.......................O1OZ20889

Bag of (16) Screws for Blank Panels.................Z1Z184566 

For additional management capabilities, order…

SNMP/HTTP Card........................................RM261C-SNMP

To control daisychained racks, order…

Control Module ...........................................................RM262C

Отзывы: