27
Standalone G-Converter
TECHNICAL: 0118 931 2233
Appendix C – EMC Requirements
To ensure compliance with the EMC directive, some care must be taken to ensure that the units
are installed properly, using suitable cables and connections. The following must be observed:
Limitation of Emissions:
'D-Type' Connections
This product relies on the use of screened cables for connection to the 15 way 'D-Type' ports.
The cables must have the foil or braid screen connected effectively to the metal headshell to
ensure continued compliance. These headshells are available from Black Box under the
following part numbers:
DB15 - FA033
DB25 - FA031
The diagram below illustrates an example of a suitable screen connection. Note how the foil or
braid screen is bent back over the 'C' clip to achieve a pressure contact of the screen against the
shell:
It is important to keep the screen to shell connection as short as possible.