7
CHAPTER 1: Specifications
D
ATA
-C
OMMUNICATIONS
C
ONTROL
S
IGNALS
:
Electrical —
CCITT V.28 (unbalanced, as per V.35)
Functional —
DCD, 64 kbps:
ON when Rx pair contains required
violations, OFF when the Rx pair does not
contain required violations;
DCD, 48 or 56 kbps:
When the Rx pair contains
the required violations, the DCD signal reflects
the state of the remote RTS; DCD is always OFF
when no violations are detected;
CTS output:
ON after RTS ON, with delay; OFF
when RTS OFF, or during Loss of Signal
condition;
DSR output:
ON (+V) when power is available
Clock Source —
From G.703 Receive pair (LBT), from DCE (EXT),
or from internal source (INT), user-selectable
Data Polarity —
Normal (MARK = “0”) or inverted (MARK = “1”),
user-selectable
O
THER
P
HYSICAL
SP
ECIFICATIONS
:
Indicators —
(5) Front-mounted LEDs: Power (PWR), Receive
Data (RD), Transmit Data (TD), Loss of Signal
(LOS), and Test (TEST)
Temperature —
32 to 122°F (0 to 50°C)
Humidity —
Up to 95% non-condensing
MTBF —
110,000 hours
Power —
Directly from outlet:
Voltage: 115 VAC (IC713A) or 230 VAC (IC713AE);
Frequency: 47 to 63 Hz;
Consumption: 25 watts;
(A –48-VDC version (IC713A-48) of the Converter is
also available; call your supplier for details)
Size —
1.8"H x 7.6"W x 9.5"D (4.6 x 19.3 x 24.1 cm)
Weight —