Manual of MEG101AE-R2 and MEG101RAE-R2 

http://www.black-box.eu 

_____________________________________________________________________________________________ 

______________________________________________________________________________ 
 
 
 

 
 
 
 

Manual 

 
 

MEG101AE-R2 

Quadband VDSL Extender Kit 

 

MEG101RAE-R2 

Quadband VDSL Receiver

 

Содержание MEG101AE-R2

Страница 1: ... eu _____________________________________________________________________________________________ ______________________________________________________________________________ Manual MEG101AE R2 Quadband VDSL Extender Kit MEG101RAE R2 Quadband VDSL Receiver ...

Страница 2: ...operations is automatically sensed and configured VDSL link rates are configured by local Modem automatically MEG101AE R2 supports auto speed and plug play operations VDSL Point to Multipoint Solution MEG801AE R2 or MEG2401AE R2 plus MEG101RAE R2 MEG101RAE R2 works together with the VDSL Quadband Switches MEG801AE R2 and MEG2401AE R2 Using these makes this system an ideal solution for delivering c...

Страница 3: ...e you can provide the right operating environment including power requirements sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirements The standard power supply coming with MEG101AE R2 and MEG101RAE R2 is intended for use in Central Europe only 220V It supplies 5V 1A For use in USA Japan Australia and UK please use Bl...

Страница 4: ...o not recommend using 28 Gauge or above phone line The active pins are the two middle pins 3 and 4 To have a clear setup we recommend to have the VDSL line 1 1 straight through So for your notice only this VDSL device works crossed and straight through VDSL Port RJ 11 Pin out Pin FUNCTION 1 NC 2 NC 3 TIP 4 RING 5 NC 6 NC Phone Port RJ 11 Here you can connect FXS FXO equipment This means that on th...

Страница 5: ...through your telephony wall socket outlet For making connectings you can alternatively use Patchpanels or anything else like terminal strips You just need to be sure that you have a good electrical connection So keep in mind that using stranded wires for use in Krone strips is not ideal Please note that connections are only operable between Transmitter and Receiver or between the switch MEG801AE R...

Страница 6: ... 25 VDSL LED It will show you that a connection to the corresponding VDSL device has been successfully established The corresponding LED 5 15 or 25 will tell you what the transfer speed is This depends on the length and the quality of the wire Rear Panel Line For connecting to the the the other side Phone For connecting FXS FXO equipment Ethernet For connecting to your Ethernet device FG For groun...

Страница 7: ...ice Check LED activity on your switch or corresponding Ethernet Device Verify that the proper cable type is used and its length does not exceed specified limits 100 Meter Check the Modem on the attached device and cable connections for possible defects Replace the defective Modem or cable if necessary Symptom VDSL Link cannot be established Cause VDSL auto speed failure or phone cable length is ov...

Страница 8: ...used frequencies 900 KHz 3 9MHz and 4MHz 7 9MHz Supports 1 RJ 11 connector for Ethernet over VDSL Supports 1 RJ 11 connector for telephone PBX connection Supports 1 RJ 45 port for 10 100Mbps Ethernet with Auto MDI MDIX Supports Auto speed and full duplex for VDSL port Supports long packet size up to 1536 bytes Voice and Data work on the same 2 wire telephone line Supports flow control IEEE802 3x f...