background image

7

MINI DRIVER MPI 

3. Installation

The Mini Driver MPI is easy to install. Follow the
steps below.

1.Separate the two parts of the plastic cover

by firmly pressing the marked places on the
sides, starting at the cable end.

2.Connect the 4-wire telephone line to the

screw terminal block; transmit pair to
"XMT" and receive pair to "RCV". Please
note the correct polarities. If you are using
shielded cables, connect the cable shield to
the "ground" terminal (optional).

3.The following polarity must be observed:

+XMT on the local Mini Driver MPI must
be connected to +RCV on the remote Mini
Driver MPI

-XMT on the local Mini Driver MPI must be
connected to -RCV on the remote Mini
Driver MPI 

(Polarity is opposite on the second pair of
wires.)

4.The Mini Driver MPI is factory set for DCE.

To operate the unit as DTE, change the
switch to the DTE position (see Figure 2).

Содержание ME761A-F

Страница 1: ...S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawre...

Страница 2: ...n a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifi...

Страница 3: ...vabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado...

Страница 4: ...ontactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser lo...

Страница 5: ...bps Operation 4 wire full or half duplex point to point or multipoint Interface RS 232 CCITT V 24 Connectors 1 DB25 male or female 1 5 screw terminal block Power From RS232 interface 6 VDC on pins 2 4...

Страница 6: ...mi 0 75 mi 0 5 mi 1 6 km 1 2 km 0 8 km 2 Introduction The Mini Driver MPI asynchronous line driver is used for local data distribution It connects full or half duplex asynchronous terminals to compute...

Страница 7: ...ntrol signal end to end the RTS one one Mini Driver MPI is passed to the DCD on the other unit Figure 1 Mini Driver MPI In A Multipoint Application The Mini Driver MPI features a switch selectable DTE...

Страница 8: ...constantly low Transmit Data Low transmit level minimizes cross talk onto adjacent circuits within the same cable Data is transmitted and received at a balanced impedance ensuring excellent immunity...

Страница 9: ...o RCV Please note the correct polarities If you are using shielded cables connect the cable shield to the ground terminal optional 3 The following polarity must be observed XMT on the local Mini Drive...

Страница 10: ...ee Figure 2 6 To close the unit press the two halves of the cover together 7 Plug the unit directly into the 25 pin connector of the terminal or computer port and fasten with the screws on each side o...

Страница 11: ...9 MINI DRIVER MPI DCE DTE Switch Schematics DTE Position DCE Position TD 2 TD 2 RD 3 RD 3 RTS 4 RTS 4 DCD CIRCUIT CTS 5 CTS 5 DSR 6 V DSR 6 DCD 8 DCD CIRCUIT DCD 8 DTR 20 DTR 20 V delay...

Страница 12: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1996 Black Box Corporation All rights reserved...