background image

Serial Interface:  DTE Shield (Pin 1) Connection to Frame Ground (JB3)

     This jumper applies to the serial interface.  In position 1 and 2, this jumper links the Protective Ground (PGND) or "DTE Shield" lead (DB25 Pin 1 or 10-pin RJ Pins 1 and 10) of the RS-232 line to the interface module's frame ground (FGND).  When this jumper is in
positions 2 and 3, the RS-232 Protective Ground on DB25 Pin 1 or RJ-45 Pins 1 and 10 is disconnected ("lifted") from frame ground.

JB5

Positions 1 and 2 = PGND and FGND Connected
Positions 2 and 3 = PGND and FGND Not Connected (default)

Serial Interface:  Signal Ground and Frame Ground (JB4)

     This jumper also applies to the serial interface.  In position 1 and 2, this jumper links the Signal Ground (SGND) lead (DB25 Pin 7 or 10-pin RJ Pin 5) of the RS-232 line to the interface module's frame ground (FGND).  When this jumper is in positions 2 and 3, RS-232
Signal Ground on DB25 Pin 7 or 10-Pin RJ Pin 5 is disconnected ("lifted") from frame ground.

JB4

Positions 1 and 2 = SGND and FGND Connected
Positions 2 and 3 = SGND and FGND Not Connected (default)

INSTALLATION:

The MicroRacks:  An Overview:

     Multi-Function LD Cards are designed to be installed in our MicroRacks (product codes RM202 for the 2-card models, RM204 for the 4-card models, RM208 for the 8-card models, and RM216 for the 16-card  models).  You will install the Multi-Function LD Cards in
any MicroRack the same way.

The MicroRacks Power Supply:

     The power supply included with the MicroRacks uses the same mid-plane architecture as the line-driver cards.  Slide the front module of the power supply into the MicroRack from the front, and slide the rear module in from the rear.  The two modules plug into one
another in the middle of the rack.  Secure the front module with thumbscrews and the rear module with conventional metal screws; these screws and thumbscrews come with the rack.

Switching the Power Supply On and Off:

     The MicroRack's power switch is located on the power supply's front panel.  When the MicroRack is plugged in and switched on, the power supply will light the red LED on its front panel.  Since the MicroRack is a "hot-swappable" rack, 

you don't have to

 

install any cards before switching on the power supply

.  Also, the power supply may be switched off at any time without harming the installed cards, and you can install or remove cards without turning off the power supply.  However, you should always

unplug the power cord before removing, replacing, or switching the power supply or its fuses.

Replacing the Power Supply's Fuse:

     The MicroRack's power supply uses a 400-mA fuse for 120-VAC circuits, and a 200-mA fuse for 240-VAC circuits.  The fuse compartment is located just below the AC socket on the power supply's rear module.  To replace the fuse, follow these steps:

1.  Making sure the rack is turned off and unplugged, use a small screw-driver to pop the compartment open:  It will slide open like a drawer.
2.  Notice that there are two fuses in the compartment:  The rear fuse is "active", and the front fuse is the "spare".
3.  If the active fuse appears to be blown, remove it from the clips and replace it with the spare from the front of the compartment.  Note the size and rating of the blown fuse before discarding it.
4.  Order a new replacement fuse.  Both 400-mA fuses (Littelfuse 239.400 or equivalent) and the 200-mA fuses (Littelfuse 239.200 or equivalent) measures 5 x 20 mm.

CAUTION:

     For continued protection against the risk of fire, replace
     blown fuses only with fuses of the same type and rating.

Switching the Power Supply Between 120 and 240 Volts:

     

Although the MicroRack is shipped form the factory with a customer-specified power-supply configuration, you may change the configuration yourself.  Follow these steps to switch the configuration of the power supply between 120 VAC and 240 VAC:

1.  Making sure the rack is turned off and unplugged, remove the power supply's front module and locate the two-position switch (labeled either "110/220" or 115/230") near the back of the card.  Slide the switch to the setting corresponding to your
     desired voltage.
2.  Replace the existing fuses with fuses of the correct type.
3.  If necessary, replace the power-supply cord with a country-specific cord.  (For certain countries, your supplier might be able to give you a special quote on country-specific cords).  Plug the cord back in.

Installing the Multi-Function LD Card in the MicroRack:

     The Multi-Function LD Card is made up of a main (front) module and an interface (rear) module.  The two cards meet inside the rack chassis; their mating 50-pin card-edge connectors plug into each other.  Use these steps to install each Multi-Function LD Card into
a MicroRack.

1.  Slide the rear module into the back of the MicroRack on the metal rails.
2.  Secure the rear module using the included metal screws.
3.  Slide the front module into the front of the chassis.  It should meet the rear module when it is almost completely in the chassis.
4.  Secure the front module using the thumbscrews.

NOTE:

     Since the MicroRacks allow "hot swapping" of cards, it is not necessary to
     power down the rack when you install or remove a Multi-Function LD Card.

     

Содержание ME759C-RJ11

Страница 1: ...ULE FRONT CARD ME759C RJ11 JB4 1 2 3 INTERFACE MODULE REAR CARD Line RJ 11 INTERFACE MODULE REAR CARD Analog 511 511E TEST Remote 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 This switch is on the bottom side o...

Страница 2: ...a when power supply is set to 120 VAC input 200 ma when power supply is set to 240 VAC input INTRODUCTION The Multi Function LD Card is a short range modem on a dual rack card it has a main front modu...

Страница 3: ...ti Function LD Card operates synchronously or asynchronously S1 7 Setting ON Asynchronously default OFF Synchronously S1 Position 8 Carrier Control Method determines whether the carrier is constantly...

Страница 4: ...tolerate S2 6 Signaling Rate Range OFF 2 5 to 1 default ON 2 5 to 2 3 S2 7 and S2 8 Word Length determines the word length that the Multi Function LD Card will expect for synchronous or asynchronous d...

Страница 5: ...he timer entirely S3 7 S3 8 Setting OFF OFF Disabled default OFF ON 12 5 Seconds ON OFF 50 Seconds ON ON 12 5 Seconds Setting the Jumpers on the Interface Module Before you install the Card you should...

Страница 6: ...power supply or its fuses Replacing the Power Supply s Fuse The MicroRack s power supply uses a 400 mA fuse for 120 VAC circuits and a 200 mA fuse for 240 VAC circuits The fuse compartment is located...

Страница 7: ...chdown block If you will be running cable directly between two Multi Function LD Cards you can get a custom cable from Black Box as a special quote or you can use regular straight through pinned cable...

Страница 8: ...modem s red CD LED will light and the remote modem s green CD LED will light B If there is flat satin cable in the line somewhere between the modems the local modem s Error LED and green CD LED will...

Страница 9: ...ilar to or better than those listed above for example lower capacitance or lower resistance Bench tests yield the following data rate maximum distance results Data Rate in bps 19 AWG 22 AWG 24 AWG 26...

Отзывы: