LIMITED-DISTANCE MODEM 56/64
Table 3-1. Strap Selection.
Strap
Function
Position
Factory
Identity
Setting
XMT
Selects timing
S1
S2
S3
Timing
clock and Async
ON
OFF
OFF
External
mode
OFF
OFF
OFF
Internal*
OFF
OFF
ON
Receive
OFF
ON
OFF
Async
Baud
Selects data
S4
Rates
transmit rate
(kbps)
ON—56 kbps
OFF-64 kbps
64
Async
Selects the
S5
Length
amount of stop
bit shortening
ON—12.5%
to be used in
OFF—25%
25%
Async mode
Selects character
S6
S7
No. Bits
length in Async
OFF
OFF
8
mode
OFF
ON
9
ON
OFF
10
10 bits
ON
ON
11
Carrier
Selects carrier
S8
constantly on, or
controlled by RTS
ON
ON
ON
OFF
CNT
Loop
ANA Enables
S9
Activation DTE control of
from DTE analog loop
ON
Enable
interface
OFF
Disable
Disable
REM Enables
S10
DTE control of
ON
Enable
remote digital
OFF
Disable
Disable
loop
*The factory setting for XMT Timing is Internal.