14
ASYNC/SYNC INDUSTRIAL LINE DRIVER
Switches S3-1 and S3-2: Input Impedance
The setting for Switches S3-1 and S3-2 determines the Line Driver’s input
impedance. This allows you to choose the optimum impedance setting for your
application. In long-distance applications, the impedance of the cable must match
the impedance of the load (or resistor) of the Async/Sync Industrial Line Driver.
Thicker-gauge cables require a lower-ohm setting, while a thinner-gauge cable
should receive a higher-ohm setting. If you are using higher speeds, you will need a
lower-ohm setting and a higher-ohm setting for the slower speeds. Refer to Table 3-
5 for assistance in selecting a setting.
S3-1
S3-2
Setting
On
On
130 ohms
On
Off
200 ohms
Off
On
320 ohms
Off
Off
High impedance (minimum 2k ohms)
Table 3-5. Speed Selection
Cable Gauge
Data Rates (kbps)
1.2
1.8
2.4
3.6
4.8
7.2
9.6
14.4
19 AWG/0.9 mm
320
320
200
200
200
200
200
130
22 AWG/0.6 mm
320
320
320
200
200
200
200
200
24 AWG/0.5 mm
320
320
320
320
200
200
200
200
26 AWG/0.4 mm
320
320
320
320
320
200
200
200
Cable Gauge
Data Rates (kbps)
16
19.2
28.8
32
38.4
57.6
64
19 AWG/0.9 mm
130
130
130
130
130
High
High
22 AWG/0.6 mm
200
130
130
130
130
High
High
24 AWG/0.5 mm
200
200
130
130
130
High
High
26 AWG/0.4 mm
200
200
200
200
130
High
High
Switch S3-3: Timing-Mode Selection
Use Switch S3-3 to select the Line Driver’s timing mode. To operate the Line
Driver at 16, 32, or 64 kbps, set S3-3 to the On position. To select any other DTE
rate, set Switch S3-3 Off.
S3-3
Setting
On
16, 32, or 64 kbps
Off
1.2 through 57 kbps, excluding 16 and 32 kbps