MDR24X User’s Manual

 

10/26/2006  

18

 

4.2

 

Programming The MDR24X units 

 

1.

 

Connect a MDR24X unit to the serial communications port on the PC. 

2.

 

Connect the power supply to the MDR24X unit.  Make sure the Pwr LED is on. 

3.

 

Start the MDR24X Configuration Utility. 

4.

 

Select the COM Port that is connected to the MDR24X unit on the PC Settings section. 

5.

 

Select the Interface Baud Rate of the MDR24X unit.  All MDR24X units are shipped with a 
default rate of 115,200 bps (unless units have been pre-configured to match specific serial 

settings).  If the Interface Baud Rate of the MDR24X unit is changed as described in Section 

4.2 Changing MDR24X Settings, then PC Setting Baud Rate must be set to the same Baud 
Rate to allow proper programming of the units. 

6.

 

Select the System Configuration for the MDR24X network, Point-to-Point (one Server and one 
Client) or Point-to-Multipoint (one Server and multiple Clients). 

7.

 

Select Read Radio to display the current settings of the MDR24X unit. 

8.

 

Change desired settings. 

9.

 

After all changes have been made, select Write Radio to save the changes. 

10.

 

Cycle Power to the unit after all changes has been saved.  This will set the MDR24X unit to its 
normal mode of operation.   

Содержание MDR24x

Страница 1: ...eless 2 4GHz Modem User s Manual Version 1 1 1000 Park Drive Lawrence PA 15055 1018 Website www blackbox com Email info blackbox com Order Toll Free in the US Call 877 877 BBOX Outside the US call 724...

Страница 2: ...tion regarding the information set forth herein BLACK BOX reserves the right to change specifications at any time and without notice BLACK BOX products are intended for use in normal commercial applic...

Страница 3: ...uirements for mobile transmitting devices this equipment must be professionally installed such that the end user is prevented from replacing the antenna with a non approved antenna The end user should...

Страница 4: ...ARK NOT DEFINED 4 2 1 ConnexLink Settings 15 4 2 2 Optional Settings 16 4 2 3 PC Settings 16 4 2 4 Additional Features 16 4 3 PROGRAMMING THE MDR24X UNITS 18 5 TROUBLESHOOTING 19 Figures Figure 1 RS 2...

Страница 5: ...pattern applied to all the transceivers in the same network A distinct hopping pattern is provided for each Channel Number thereby allowing multiple networks to co exist in the same area without inter...

Страница 6: ...cy band RF Technology 2402 2478MHz FHSS Supported Network Topologies Point to Point Point to Multipoint Channels 40 US Canada Europe 20 France Security One byte System ID ANTENNA RF Connector RPSMA Ja...

Страница 7: ...ceivers offer performance improvements over a standard cabled link Distance and multipoint communications are greatly enhanced A selection of RS 232 RS 485 can be made when ordering the MDR24Xs Figure...

Страница 8: ...dard power is applied through the power connector Alternative power is available via the terminal block pins Pin Description Input Output 1 DCD O 2 TxD O 3 RxD I 4 DSR O 5 GND 6 DTR I 7 CTS O 8 RTS I...

Страница 9: ...Reverse Polarity 0 000 0 375 0 000 0 536 0 060 9 Pin Male D Connector Power Jack w 0 100 dia pin and 0 250 opening pin is PWR 0 538 J3 J4 2 375 2 750 4 500 4 750 2 000 0 150 dia mounting holes 4 plac...

Страница 10: ...cable is required The null modem simply swaps pins to convert a DCE to a DTE and vice versa A null modem cable can be provided with the MDR24X on request The MDR24X transceivers support the following...

Страница 11: ...tive with respect to common RS 232 has numerous handshaking lines primarily used with modems and also specifies a communications protocol Figure 5 RS 232 Male Female Connector Pin out RS 232 DB9 Femal...

Страница 12: ...network The MDR24X implements a RS 485 2 wire Half Duplex multi drop interface Typically a RS 485 bus will consist of a master and several slaves The nodes will have unique addresses and can send add...

Страница 13: ...end data while the MDR24X buffer is full that data will be discarded To avoid this situation the MDR24X will de assert CTS as a warning that the buffer is filling The host device should stop sending d...

Страница 14: ...single communications cable A point to point link might be used to connect a PLC to a remote monitoring station Figure 8 Point to Point Network 3 2 Point to Multipoint Point to Multipoint systems hav...

Страница 15: ...d Rate setting of its host device Random Back Off In an asynchronous network where any node can talk at any time the MDR24X can be programmed to use Random Back Off to mitigate the RF Link If two node...

Страница 16: ...tem Config selection that was made when the MDR24X was configured Firmware Version Displays the MDR24X s firmware version MAC Address A unique 6 Byte IEEE 802 3 Ethernet address assigned by Black Box...

Страница 17: ...eviously known working configuration The first time that a radio is read with Auto Archive enabled will be stored as the Original Configuration Settings with the date and time the record was created S...

Страница 18: ...to match specific serial settings If the Interface Baud Rate of the MDR24X unit is changed as described in Section 4 2 Changing MDR24X Settings then PC Setting Baud Rate must be set to the same Baud R...

Страница 19: ...received 1 Verify that the baud rate of the MDR24X matches that of the MDR24X host device Client s Link LED does not come on 1 Make sure the unit is connected to power 2 Cycle power to the radio 3 Ver...

Отзывы: