Black Box LPH3100A Скачать руководство пользователя страница 4

STEP 2 - 

Connect the Power

POWER CONNECTION STEPS

 

The LPH3100A switch supports dual +12 to  
24 VDC power inputs and changes relay status 
when the power fails.
1.  Insert the positive and negative wires  

into the V+ and V- contacts on the terminal 
block connector.

2.  Tighten the wire clamp screws to prevent  

the DC wires from loosening.

3.  Link a closed-loop device (such as an alarm 

system) to P-Fail for transmit signals only,

+

+

_

_

+ _

_

+ _

PWR2        1A @ 24V      PWR1

V2-    V2+ 

V1-    V1+ 

P-Fail

Single DC Power

Redundant DC Power

Chassis 

GND

Chassis 

GND

One DC Supply

Dual DC Supplies

Connection to 

Grounding Point

Drain Wire  

with Lug

Содержание LPH3100A

Страница 1: ...STEP X Name of Step 24 7 TECHNICAL SUPPORT AT 877 877 2269 OR VISIT BLACKBOX COM LPH3100A INDUSTRIAL POE SWITCH QUICK START GUIDE ...

Страница 2: ...STEP 1 Package Includes WHAT S INCLUDED 1 LPH3100A INDUSTRIAL POE SWITCH 2 WALLMOUNTING PLATES WITH SCREWS 1 DIN RAIL MOUNTING BRACKET WITH SCREWS THIS QUICK START GUIDE ...

Страница 3: ...rdware Overview TABLE 1 LPH3100A COMPONENTS NUMBER DESCRIPTION 1 2 RJ 45 Ethernet ports 2 8 RJ 45 Ethernet PoE ports 3 Link Activity LED 4 Speed LED 5 Power 1 LED 6 Power 2 LED 7 Power Fail LED 8 Loop LED 5 6 7 8 1 2 3 4 ...

Страница 4: ...o the V and V contacts on the terminal block connector 2 Tighten the wire clamp screws to prevent the DC wires from loosening 3 Link a closed loop device such as an alarm system to P Fail for transmit signals only _ _ _ _ _ PWR2 1A 24V PWR1 V2 V2 V1 V1 P Fail Single DC Power Redundant DC Power Chassis GND Chassis GND One DC Supply Dual DC Supplies Connection to Grounding Point Drain Wire with Lug ...

Страница 5: ...THE DIN RAIL KIT Attach the DIN rail bracket to the DIN rail using the included screws See Figure A 2 1 REMOVING THE DIN RAIL KIT 1 Remove the screws from the DIN rail 2 Lift the switch up and off from the DIN rail See Figure B 2 1 B A B A ...

Страница 6: ...STEP 3B Wallmounting WALLMOUNTING STEPS 1 Using the included screws attach the wallmounting plates to the wall 2 Slide the switch onto the mounting plates CAUTION Do not block air ventilation holes ...

Страница 7: ...LED Solid green Powered ON OFF Powered OFF or not installed 2 PWR 2 LED Solid green Powered ON OFF Powered OFF or not installed 3 P Fail Solid red Lights when PWR1 or PWR2 is disconnected OFF OFF when PWR1 or PWR2 is connected 4 Loop Solid red Lights when a loop is detected OFF No loop detected 1 2 3 4 P1 P2 P Fail Loop ...

Страница 8: ...STEP X Name of Step COPYRIGHT 2017 BLACK BOX CORPORATION ALL RIGHTS RESERVED ...

Отзывы: