background image

Quick Start Guide

• LIG1014A has (10) RJ-45 ports and (4) SFP slots. 
• LIE1014A has (8) PoE+ RJ-45 ports and (4) SFP slots.

Industrial Managed Gigabit Ethernet Switch

LIG1014A 

LIE1014A

Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S.  
call 724-746-5500)  •  FREE technical support 24 hours a day, 7 days  
a week: Call 724-746-5500 or fax 724-746-0746   
www.blackbox.com   •  [email protected]

Customer 

Support 

Information

Содержание LIE1014A

Страница 1: ... SFP slots Industrial Managed Gigabit Ethernet Switch LIG1014A LIE1014A Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 www blackbox com info blackbox com Customer Support Information ...

Страница 2: ...ram LIG1014A 8 1 2 Front Panel Connectors LIG1014A 8 1 3 Front Panel LEDs LIG1014A 8 1 4 Front Panel Diagram LIE1014A 10 1 5 Front Panel Connectors LIE1014A 10 1 6 Front Panel LEDs LIE1014A 11 2 What s Included 12 3 Installation 13 3 1 Mounting the Switch on a DIN Rail 13 3 2 Mounting the Switch on a Wall 14 3 3 Ethernet Interface 14 3 3 1 RJ 45 14 3 3 2 Fiber SFP 16 3 4 Connecting the Power Termi...

Страница 3: ... to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le présent a...

Страница 4: ...bra o superficie similar puede bloquea la ventilación no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuent...

Страница 5: ...o sean derramados sobre la cubierta u orificios de ventilación 18 Servicio por personal calificado deberá ser provisto cuando A El cable de poder o el contacto ha sido dañado u B Objectos han caído o líquido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempeño o E El aparato ha sido tirado o...

Страница 6: ...crossover 4 100 1000BASE SFP module slot Ingress protection IP30 Dimensions with out DIN rail clip LIG1014A 6 0 H x 2 4 W x 4 3 D 15 4 x 6 x 10 9 cm LIE1014A 6 1 H x 3 0 W x 5 0 D 15 4 x 7 7 x 12 8 cm Weight LIG1014A 2 4 lb 1 1 kg LIE1014A 3 1 lb 1 4 kg Installation Options DIN rail mounting Wallmounting Power PoE LIG1014A No LIE1014A Yes Input Redundant input terminals reverse power protection In...

Страница 7: ...ns Power continued Maximum Power LIG1014A 17 Watts LIE1014A Without PoE 14 Watts With PoE 265 Watts Environmental Operating Temperature 40 to 167 F 40 to 75 C cold startup at 40 C Storage Temperature 40 to 185 F 40 to 85 C Humidity 5 to 95 RH non condensing ...

Страница 8: ...Panel Diagram LIG10141 Connector Description 10 RJ 45 10 100 1000 Mbps speed auto negotiation MDI MDI X auto crossover 4 SFP slots 100 1000BASE SFP module slot 1 2 Front Panel Connectors LIG1014A Figure 1 3 Front panel LIG1014A P1 P2 ALM 1 3 5 7 9 11 13 2 4 6 8 10 12 14 ...

Страница 9: ... Power failure alarm occurs OFF No power failure alarm 10 Link Act LEDs for RJ 45 ports On Green Ethernet link is up but no traffic is detected OFF Ethernet link is down 10 Speed LEDs for RJ 45 ports ON Yellow 1000 Mbps connection is detected OFF No link a 10 Mbps or 100 Mbps connection is detected 4 Link Act LED for SFP port ON Green Ethernet link is up OFF Ethernet link is down 4 Speed LED for S...

Страница 10: ... 1 4 Front Panel Diagram LIE1014A P1 P2 ALM Connector Description 8 RJ 45 PoE 10 100 1000 Mbps speed auto negotiation MDI MDI X auto crossover with PoE 4 SFP slots 100 1000BASE SFP module slot 1 7 Front Panel Connectors LIE1014A Figure 1 4 Front panel LIE1014A ...

Страница 11: ...wer failure alarm occurs OFF No power failure alarm 8 Link Act LEDs for RJ 45 PoE ports On Green Ethernet link is up but no traffic is detected OFF Ethernet link is down 8 Speed LEDs for RJ 45 PoE ports ON Yellow 1000 Mbps connection is detected OFF No link a 10 Mbps or 100 Mbps connection is detected 4 Link Act LED for SFP port ON Green Ethernet link is up OFF Ethernet link is down 4 Speed LED fo...

Страница 12: ...Support at 724 746 5500 or info blackbox com 1 Industrial Managed Gigabit Ethernet Switch 10 RJ 45 4 SFP LIG1014A OR 1 Industrial Managed Gigabit Ethernet PoE Switch 8 RJ 45 4 SFP LIE1014A 2 wallmount brackets 1 DIN rail clip 4 M3 screws for the wallmount brackets or DIN rail clip 1 DC power terminal block 10 or 8 RJ 45 connector dust covers 4 SFP port dust covers This Quick Start Guide ...

Страница 13: ...d fiber is broken your eyes might be exposed to to hazardous laser output power 3 1 Mounting the Switch on a DIN Rail 1 Screw the DIN rail bracket onto the switch with the included bracket and screws 2 Hook the switch DIN rail bracket assembly over the DIN rail 3 Push the bottom of the assembly towards the DIN rail until it snaps into place Figure 3 1 Din rail mounting ...

Страница 14: ... P1 P2 ALM Figure 3 2 Wallmounting 3 3 Ethernet Interface The switch has two types of Ethernet interfaces electrical RJ 45 and optical SFP interfaces 3 3 1 RJ 45 To connect the switch to a PC use straight through or cross over Ethernet cables To connect the switch to an Ethernet device use UTP Unshielded Twisted Pair or STP Shielded Twisted Pair Ethernet cables ...

Страница 15: ...in the following figure and tables LED A LED B Pin 8 Pin 1 Figure 3 3 RJ 45 connector pinout Table 3 1 RJ 45 pinout descriptions Pin Assignment PoE Assignment LIE1014A only 1 2 TX RX TX RX Positive Vport 3 6 TX RX TX RX Negative Vport 4 5 TX RX TX RX Not used 7 8 TX RX TX RX Not used ...

Страница 16: ...cally have an LC connector The fiber transceivers have options of multimode single mode long haul or special application transceivers DANGER Never attempt to view optical connectors that might be emitting laser energy Do not power up the laser product without connecting the laser to the optical fiber and putting the dust cover in position as laser outputs will emit infrared laser light at this poi...

Страница 17: ...le mode 1310 nm 10 km LFP414 SFP 1250 Extended Diagnostics LC single mode 1310 nm 40 km LFP401 SFP 155 Extended Diagnostics LC multimode 850 nm 2 km LFP403 SFP 155 Extended Diagnostics LC single mode 1310 nm 30 km LFP404 SFP 155 Extended Diagnostics LC single mode 1310 nm 60 km LFP402 SFP 155 Extended Diagnostics LC multimode 1310 nm 2 km LFP418 SFP 1250 Extended Diagnostics LC single mode 1550 nm...

Страница 18: ...d from two power supplies input range 12V 58V Insert the positive and negative wires into V and V contacts on the terminal block respectively and tighten the wire clamp screws to prevent the wires from loosening LIG1014A First power supply Second power supply PWR1 ALM PWR2 Console Reset Figure 3 4 Terminal block LIG1014A ...

Страница 19: ...724 746 5500 blackbox com Page 19 Chapter 3 Installation LIE1014A PWR1 ALM PWR2 Console Reset Second power supply First power supply Figure 3 5 Terminal block LIE1014A ...

Страница 20: ...nector as shown in the figure below The alarm relay out is Normal Open and it will be closed when detected any predefined failure such as power failures or Ethernet link failures The relay output with current carrying capacity of 0 5 A 24 VDC Extra power system Alarm system Ground connector PWR1 ALM PWR2 Console Reset Figure 3 6 Alarm relay LIG1014A or LIE1014A ...

Страница 21: ...ector connect to computer COM port Baud rate 115200bps 8 data bits 1 stop bit No Priority No flow control PWR1 ALM PWR2 Console Reset Figure 3 7 Console connector LIG1014A or LIE1014A An RJ 45 male connector to RS 232 DB9 female connector cable is required The RJ 45 connector of the cable is connected to the console connector on the switch The pin assignment of the console cable is shown on the ne...

Страница 22: ...naged Switch 2 Factory default IP 192 0 2 1 3 Login with default account and password Username admin Password none 3 8 CLI Initialization and Configuration Optional 1 Connecting to the Ethernet port RJ45 Ethernet port of Managed Switch 2 Key in the command under Telnet telnet 192 0 2 1 3 Login with default account and password Username admin Password none ...

Страница 23: ...724 746 5500 blackbox com Page 23 Chapter 3 Installation 4 Change the IP with commands listed below CLI Command enable configure terminal interface vlan 1 ip address xxx xxx xxx xxx xxx xxx xxx xxx exit ...

Страница 24: ...e live 24 7 Tech support available in 60 seconds or less Copyright 2016 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners Great tech support is just 60 seconds away at 724 746 5500 or blackbox com Black Box...

Отзывы: