Class A (using DC terminal power or Power over Ethernet (PoE).  This 
equipment has been tested and found to comply with the limits for a Class B 
computing device pursuant to Part 15 of the FCC Rules.  These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation.  However, there is no guarantee that interference will not 
occur in a particular installation.  This equipment generates, uses, and can 
radiate radio frequency energy, and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications.  If this 
equipment does cause harmful interference to radio or telephone reception, 
which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one of the following measures: 

 Reorient 

or 

relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which 
the receiver is connected. 

 

Consult an experienced radio/TV technician for help. 

 
Class B (using any DC jack options).  .  This equipment has been tested and 
found to comply with the limits for a Class B computing device pursuant to Part 
15 of the FCC Rules.  These limits are designed to provide reasonable protection 
against harmful interference in a residential installation.  However, there is no 
guarantee that interference will not occur in a particular installation.  This 
equipment generates, uses, and can radiate radio frequency energy, and, if not 
installed and used in accordance with the instructions, may cause harmful 
interference to radio communications.  If this equipment does cause harmful 
interference to radio or telephone reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the 
interference by one of the following measures: 

 Reorient 

or 

relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which 
the receiver is connected. 

 

Consult an experienced radio/TV technician for help. 

 

CAUTION 

Changes or modifications not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment. 
 
To meet FCC requirements, shielded cables and power cords are required to 
connect this device to a personal computer or other Class B certified device. 
 
This digital apparatus does not exceed the Class B limits for radio noise 
emission from digital apparatus set out in the Radio Interference Regulation 
of Industry Canada. 
 

Содержание LIC022A-R2

Страница 1: ... LIC054A R2 LIC023A R2 LIC027A R2 LIC055A R2 LIC024A R2 LIC052A R2 LIC056A R2 LIC025A R2 LIC053A R2 LIC057A R2 MultiPower Industrial Media Converters Choose from four different ways to power these hardened media converters ...

Страница 2: ...LIC022A R2 TRADEMARKS USED IN THIS MANUAL Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Страница 3: ...ed and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation However there is no guarantee that interference will not occur in a particular installation This equipment generates uses and can radiate radio frequency energy and if not ins...

Страница 4: ...s the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about proper disposal please contact local authorities wast...

Страница 5: ...MultiPower Industrial Media Converters 9 3 1 DIN Rail Mounting 9 3 2 Cascading DC Power 9 3 3 Powering the MultiPower Industrial Media Converters 10 3 4 About Power over Ethernet PoE and MultiPower Industrial Media Converters 10 3 5 DC Terminal Block Wiring Instructions 10 4 Operation 11 5 Contacting Black Box 12 6 Fiber Optic Cleaning Guidelines 13 7 Electrostatic Discharge Precautions 14 ...

Страница 6: ...PLUS SC 30 km LIC026A R2 TP TX FX SM1310 LONG ST 80 km LIC027A R2 TP TX FX SM1310 LONG SC 80 km LIC052A R2 TP TX SSFX SM1310 SC 1310xmt 1550rcv 20km LIC053A R2 TP TX SSFX SM1550 SC 1550xmt 1310rcv 20km LIC054A R2 TP TX SSFX SM1310 PLUS SC 1310xmt 1550rcv 40km LIC055A R2 TP TX SSFX SM1550 PLUS SC 1550xmt 1310rcv 40km LIC056A R2 TP TX SSFX SM1310 LONG SC 1310xmt 1550rcv 60km LIC057A R2 TP TX SSFX SM...

Страница 7: ...When MultiPower Industrial Media Converters use PoE technology to be a PD the maximum supply voltage is 50V AC Wall Adapter 100 to 240 10 VAC input 5 VDC output 2A max Power Consumption Typical 500mA 5 VDC Operating Temperature DC configurations 13 F to 185 F 25 C to 85 C With AC wall adapter 14 F to 122 F 10 C to 50 C Storage Temperature 40 F to 185 F 40 C to 85 C Humidity 5 to 95 non condensing ...

Страница 8: ...ltiPower Industrial Media Converters are fixed fiber transceiver models that include one 10 100 Mbps RJ 45 connector and one 10 100 Mbps SC fiber connector which can support Single Mode fiber or Multi Mode fiber in Dual Strand or Single Strand fiber The MultiPower Industrial Media Converters are Industrial Ethernet devices which allows for extended temperature operation of 25ºC to 85ºC for DC powe...

Страница 9: ...owing installation on a DIN rail Depending on the installation the MultiPower Industrial Media Converters can be mounted parallel or perpendicular to the DIN rail Use the supplied screws to attach the DIN clips to the MultiPower Industrial Media Converters and then snap the converter to the DIN rail To remove the converter from the DIN rail use a flat head screwdriver in the slot to gently pry the...

Страница 10: ... Equipment PSE Power Sourcing Equipment distributes an electrical current across existing copper data cabling 3 5 DC Terminal Block Wiring Instructions The MultiPower Industrial Media Converters can also be powered with the DC terminal block From a power source connect to any one positive and any one negative terminal on the MultiPower Industrial Media Converters NOTE When using stranded wire the ...

Страница 11: ...5 connector LED functions are as follows LED functions are as follows above illustration is representative FX LNK ACT Glows green when a link is established on the fiber port blinks green when activity is detected on the fiber port TX LNK ACT Glows amber when a link is established on the copper port blinks amber when activity is detected on the copper port ...

Страница 12: ...ox Customer Service Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Free technical support 24 hours a day 7 days a week Call 877 877 2269 or Fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com ...

Страница 13: ...ow quality components can cause many hard to diagnose problems in an installation 2 Dust caps are installed at Black Box to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber cable to the device If you need to disconnect the fiber device reinstall the protective dust caps 3 Store spare caps in a dust free environment such as a ...

Страница 14: ... the wrist strap is not available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the modules or stand alone units over any surface WARNING Integ...

Страница 15: ...Notes LIC022A R2 877 877 2269 blackbox com Page 15 ...

Страница 16: ...LIC022A R2 Rev 1 55 80722BB 00 Rev B3 877 877 2269 ...

Отзывы: