4. Installation

This chapter gives step-by-step installation instructions for the Hardened Ethernet Extender.

4.1 Selecting a Site for the Equipment

As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or 
electromagnetic interference. Specifically, the site you select should meet the following requirements:

• The surrounding air temperature should be between -40 to +167° F (-40 to +75° C).

• The relative humidity should be less than 95 percent, noncondensing.

• Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards.

• Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes of the equipment.

• The power outlet should be within 6 feet (1.8 meters) of the product.

4.2 Wiring Diagram

Field Wiring Terminal Markings: Use copper conductors only, 140° F/167° F (60° C/75° C) , wire range 12-24 AWG, torque value 7 

lb-in.

Local mode

Remote mode

RJ-11 connector, twisted-
pair copper telephone line

RJ-45 connector,  
twisted-pair copper wire

RJ-45 connector,  
twisted-pair copper wire

Power 1, DC jack, 48 VDC

Power 2, terminal block, 24-48 VDC

Power 3, terminal 
block, 24-48 VDC

Ground

Field wiring terminal: 
Use copper  
conductors only, 

60/75° C, 12-24 

AWG, torque value  
7 lb.-in. 

Power 3, terminal 
block, 24-48 VDC

Power 3, terminal 
block, 24-48 VDC

Ground

Power 1, DC 
jack, 48 VDC

Figure 4-1. Wiring diagram using RJ-11 connector for copper telephone line.

Содержание LB304A

Страница 1: ...r toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Customer Support Information LB304A LBPS301A LBPS304A ...

Страница 2: ...emark of Underwriters Laboratories Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners We re here to help If you have any questions about your application or our products contact Black Box Tech Support at 724 746 5500 or go to blackbox com and click on Talk to Black Box You ll be live with one of our technical experts in less than 30 s...

Страница 3: ...en the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate ...

Страница 4: ...an el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el aparato 12 Precau...

Страница 5: ... the Hardened Ethernet Extender of choice for harsh environments with space constraints QS1 Physical Description The Port Status LEDs and Power Inputs Figure QS 1 LBPS304A LBPS301A LB304A Table QS 1 Power input assignment Power Signal Voltage Connector Power 1 48 VDC DC jack Power 2 24 48 VDC Terminal block Power Ground Power 3 24 48 VDC Power Ground Earth Ground ...

Страница 6: ...g or receiving data ACT stands for ACTIVITY Off Valid network connection not established or not transmitting receiving data Speed Yellow Steady Valid port connection at 100 Mbps Off Valid port connection at 10 Mbps Ethernet Extender LEDs Remote Steady The device operates in remote mode Local Steady The device operates in local mode Error Steady Error occurred Link Steady A valid connection establi...

Страница 7: ...e pinouts of 10 100BASE TX RJ 45 port Table QS 5 describes the functions Figure QS 2 RJ 45 port pinout Table QS 5 10 100BASE TX RJ 45 port pin assignments Pin Regular Ports Uplink Ports 1 Output Transmit Data Input Receive Data 2 Output Transmit Data Input Receive Data 3 Input Receive Data Output Transmit Data 4 Positive VCC Positive VCC 5 Positive VCC Positive VCC 6 Input Receive Data Output Tran...

Страница 8: ...ASE TX 2 port IEEE 802 3at PoE PSE Ethernet Extender 2 88 A 24 VDC 1 44 A 48 VDC Power consumption 69 12 W Max 2 port IEEE 802 3at PoE PSE Ethernet Extender 2 88 A 24 VDC 1 44 A 48 VDC Power consumption 69 12 W Max 1 port IEEE 802 3at PoE PSE Ethernet Extender 1 6 A 24 VDC 0 8 A 48 VDC Power consumption 38 4 W Max 4 port 10 100BASE TX Ethernet Extender 0 36 A 24 VDC 0 18A 48 VDC Power consumption ...

Страница 9: ...to install and use the Hardened Ethernet Extender The Hardened Ethernet Extender provides one channel for Ethernet over existing voice grade twisted pair copper wire The Hardened Ethernet Extender fully complies with IEEE 802 3 10BASE T and IEEE 802 3u 100BASE TX FX standards ...

Страница 10: ... 11 2 Overview 12 2 1 Introduction 12 2 2 Features 12 2 3 What s Included 12 2 4 Hardware Description 13 3 Configuration 15 3 1 One Channel Hardened Ethernet Extender 15 3 1 1 DIP Switch 15 3 1 2 Front Panel 16 4 Installation 18 4 1 Selecting a Site for the Equipment 18 4 2 Wiring Diagram 18 4 3 DIN Rail Mounting 19 4 4 Connecting to Power 19 4 4 1 Redundant DC Terminal Block Power Inputs 19 4 4 2...

Страница 11: ...s for half full duplex 100BASE TX 100 200 Mbps for half full duplex Standards IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX Ethernet over VDSL IEEE 802 3at Switching Method Store and forward Connectors LBPS301A 1 RJ 45 1 RJ 11 1 2 position terminal block LBPS304A LB304A 4 RJ 45 1 RJ 11 1 2 position terminal block Indicators LEDs Per port LBPS304A LB304A 2 RJ 45 LBS301A 2 RJ 45 All models Link ACT Gre...

Страница 12: ...mt Ten speeds with speed indicator LEDs on front panel of unit up to 50 Mbps about 984 feet 300 meters down to 1 Mbps about 6232 feet 1900 meters 4 port 10 100BASE TX 2 port IEEE 802 3at PoE PSE Ethernet Extender 2 88 A 24 VDC 1 44 A 48 VDC Power consumption 69 12 W Max 1 port IEEE 802 3at PoE PSE Ethernet Extender 1 6 A 24 VDC 0 8 A 48 VDC Power consumption 38 4W Max 4 port 10 100BASE TX Ethernet...

Страница 13: ... on LED is off when power is off 2 Power LED 2 Lights steady when power is on LED is off when power is off 3 Power LED 3 Lights steady when power is on LED is off when power is off 4 Reset button Press to reset the unit 5 2 PoE LEDs Lights when powered device PD is connected 6 Speed LEDs 1 3 5 10 15 20 25 30 40 50 Mbps Lights to indicate speed from 1 50 Mbps 7 4 RJ 45 connectors Links to Ethernet ...

Страница 14: ...bps 7 1 RJ 45 connector Links to Ethernet devices 8 1 RJ 11 connector Links to twisted pair cable 9 1 2 position terminal block Links to twisted pair cable Table 2 3 LB304A Components Number Component Description 1 Power LED 1 Lights steady when power is on LED is off when power is off 2 Power LED 2 Lights steady when power is on LED is off when power is off 3 Power LED 3 Lights steady when power ...

Страница 15: ...nder port it uses RJ 11 and terminal block connectors and autosenses 1 3 5 10 15 20 25 30 40 50 Mbps speeds Ethernet Extender Mode Settings Ethernet Extender mode settings are simple via a DIP Dual Inline Package switch on the top panel of the Hardened Ethernet Extender DIP Switch There is one pin on the DIP switch for Ethernet Extender mode settings Refer to Table 3 1 for more details Table 3 1 D...

Страница 16: ...g or receiving data ACT stands for ACTIVITY Off Valid network connection not established or not transmitting receiving data Speed Yellow Steady Valid port connection at 100 Mbps Off Valid port connection at 10 Mbps Ethernet Extender LEDs Remote Steady The device operates in remote mode Local Steady The device operates in local mode Error Steady Error occurred Link Steady A valid connection establi...

Страница 17: ...itive VCC 6 Input Receive Data Output Transmit Data 7 Negative VCC Negative VCC 8 Negative VCC Negative VCC NOTE Pin 4 5 Positive VCC and Pin 7 8 Negative VCC are only available for Hardened IEEE 802 3at PoE PSE Ethernet Extender versions LBPS301A LBPS304A Ethernet Extender Connection The RJ 11 and Terminal Block port pinouts are shown in Figure 3 2 and described in Table 3 5 Figure 3 2 RJ 11 and ...

Страница 18: ...ld RFC standards Make sure that the equipment receives adequate ventilation Do not block the ventilation holes of the equipment The power outlet should be within 6 feet 1 8 meters of the product 4 2 Wiring Diagram Field Wiring Terminal Markings Use copper conductors only 140 F 167 F 60 C 75 C wire range 12 24 AWG torque value 7 lb in Local mode Remote mode RJ 11 connector twisted pair copper telep...

Страница 19: ...telephone line 4 3 DIN Rail Mounting Attach the DIN rail plate to the back panel of the Hardened Ethernet Extender Installation Place the Hardened Ethernet Extender on the DIN rail from above using the slot Push the front of the Hardened Ethernet Extender toward the mounting surface until it audibly snaps into place Removal Pull out the lower edge and then remove the Hardened Ethernet Extender fro...

Страница 20: ...o DC power adapter to the receptacle on the top side of the Hardened Ethernet Extender Step 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage Figure 4 4 Table 4 1 Power Input Assignment Power Signal Voltage Connector Power 1 48 VDC DC jack Power 2 24 48 VDC Terminal block Power Ground Power 3 24 48 VDC Power Ground ...

Страница 21: ...724 746 5500 blackbox com Page 21 NOTES ...

Страница 22: ...724 746 5500 blackbox com Page 22 NOTES ...

Страница 23: ...724 746 5500 blackbox com Page 23 NOTES ...

Страница 24: ...power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 30 seconds or less Copyright 2011 Black Box Corporation All rights reserved Black Box Tech Support FREE Live 24 7 Tech support the way it should be Great tech support is just 30 seconds away at 724 746 5500 or blackbox com LB304A version 1 ...

Отзывы: