10
V.35
↔
HSSI INTERFACE CONVERTERS
Figure 3-3 shows the orientation of the switches on DIP Switch S1 with respect
to ON/OFF positions. The default settings for DIP Switch S1 are shown in
Table 3-1. Detailed descriptions of each switch follow the table.
Figure 3-3. Closeup of the DIP switches.
Table 3-1. DIP-switch summary
Position
Function
Factory Default
S1-1
Clock Source
On
HSSI ST
S1-2
Clock Source
Off
Signal
S1-3
Sync Method
Off
Bypass
S1-4
Sync Method
On
Sync Circuit
1 2 3 4
ON
OFF
ON