background image

SEPTEMBER 1999

IC610A
IC612A

V.35 Rate Adapter/64

X.21 Rate Adapter/64

CUSTOMER SUPPORT INFORMATION

Order 

toll-free

in the U.S.: Call 

877-877-BBOX

(outside U.S. call 

724-746-5500

)

FREE technical support 24 hours a day, 7 days a week: Call 

724-746-5500

or fax 

724-746-0746

Mailing address: 

Black Box Corporation

, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: 

www.blackbox.com

•   E-mail: 

[email protected]

RATE

ADAPTER/64

Содержание IC610A

Страница 1: ...er toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com RATE ADAPTER 64 ...

Страница 2: ...nt in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio ...

Страница 3: ...vabo sótano mojado o cerca de una alberca etc 6 El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación Todo...

Страница 4: ...contactos y receptáculos donde salen del aparato 14 El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deberá ser localizada lejos de las lineas de energia 16 El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera qu...

Страница 5: ...o CCITT I 463 V 110 Interface Terminal side EIA 232 C CCITT V 24 DCE side CCITT V 35 IC610A model or X 21 IC612A model Connectors Terminal side DB25 female DCE side DB15 female IC612A or 34 pin M block female IC610A Indicators Power green LED Sync loss red LED lights up at loss of synchronization Temperature 32 to 122 F 0 to 50 C Humidity Up to 95 noncondensing Power 115 VAC 7 5 V at 300 mA suppli...

Страница 6: ...V 110 recommendations Compatible with CCITT V 35 or X 21 2 2 Description The Rate Adapter 64 lets your EIA 232 compliant DTEs running at up to 19 2 kbps exchange data over 64 kbps channels on an ISDN circuit The Rate Adapter 64 converts the DTE speed up to 19 2 kbps of your PCs terminals etc to the Bearer B channel 64 kbps rate associated with high speed digital transmission service ISDN unformatt...

Страница 7: ...of signal synchronization The Rate Adapter 64 is not limited to the ISDN environment It can be used in any application that requires conversion from EIA 232 V 24 low speed data rates up to 19 2 kbps to a V 35 or X 21 high speed 64 kbps channel The lightweight and compact Rate Adapter 64 is easy to install average installation time is about 10 minutes Power is supplied by an external wall mount pow...

Страница 8: ...tip of the tool levers downward Repeat this procedure for all the marked areas Warning Do not insert the screwdriver straight into the middle of the slot this may break off the prongs that secure the covers 2 Set Switch 1 SW1 to the proper EIA 232 data rate for your DTE according to the table below SW1 SWITCH POSITIONS RATE 1 2 3 OFF OFF OFF 600 ON OFF OFF 1200 OFF ON OFF 2400 ON ON OFF 4800 OFF O...

Страница 9: ...Rate Adapter 64 to accommodate the proper character length including start and stop bits Use Switch Positions 2 and 3 of SW2 to set async data character length SW2 SWITCH POSITIONS TOTAL BITS 2 3 OFF ON 8 bits ON ON 9 bits OFF OFF 10 bits ON OFF 11 bits NOTE SW2 switch position 4 is not connected 5 Close the unit by pressing both halves together 6 Plug the connector into the AC power supply 7 Plug...

Страница 10: ...ected to an ISDN U interface multiplexor Figure 3 Rate Adapter 64 strapping diagram SW1 ON OFF BAUD RATE N C SW2 OFF ON ASYNC SYNC NO OF BITS N C DATA TERMINAL RATE ADAPTER 64 IC610A IC612A ISD U TERMINAL ADAPTER PSTN PSTN ISD U BRI LINE Data Terminal Rate Adapter 64 Rate Adapter 64 Data Terminal Multiplexors ...

Страница 11: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1999 Black Box Corporation All rights reserved ...

Отзывы: