35
B.2 Pinout on DB9 (IC473A, IC630A, and IC631A Models)
The IC473A, IC630A, and IC631A models of the
Converter have an RS-232 interface pinned out according
to the TIA-574 standard, as shown below, on a PC-
compatible DB9 female (pictured) or male connector.
These models of the Converter are always DCE; they
receive data on Transmit Data (TD, Pin 3) and transmit
on Receive Data (RD, Pin 2). Two pairs of RS-232
control signals, RTS/CTS and DTR/CD, are jumpered
together inside the Converter. If the Converter receives
Request to Send (RTS) on Pin 7, the Converter loops it
back on the Clear to Send line (CTS, Pin 8), and vice
versa. And if the Converter receives Data Terminal Ready
(DTR, Pin 4), the Converter loops it back on the Carrier
Detect line (CD, Pin 1). Also, if the converter receives
signals on any of these lines or on TD (Pin 3), it emits a
small positive voltage on the Data Set Ready (DSR, Pin 6).
Dir. Signal Name (Abbrev.) Pin Pin Signal Name (Abbrev.) Dir.
APPENDIX B: RS-232 Pinouts
OUT
Data Set Ready (DSR) – 6
IN
Request to Send (RTS) – 7
OUT
Clear to Send (CTS) – 8
1 – Carrier Detect (CD)
OUT
2 – Receive Data (RD)
OUT
3 – Transmit Data (TD)
IN
4 – Data Term. Ready (DTR) IN
5 – Signal Ground (SGND)
N/A
Содержание IC470A
Страница 40: ...NOTES ...