EXPRESS 8-PORT MUX

6

2. Introduction

This users’ manual applies to the Express 8-Port Mux, which is used with the IBM 5250 protocol. The 5250
family of products consists of IBM System 34, 36, 38, and the AS/400

®

, along with many supporting devices

manufactured by IBM and other companies. The Express 8-Port Mux works with all supporting devices that are
designed within the 5250 specifications.

2.1 Description

The Express 8-Port Mux has the unique ability to allow multiple AS/400 controller polling groups to be
transmitted over a single fiber optic pair. This feature allows all new AS/400e controllers to provide their
maximum throughput potential, in either 1-Mbps Optimized or 2-Mbps Express mode, by transparently
multiplexing the “split-polling” feature without requiring performance-robbing PTFs (Programming
Temporary Fixes).

All new IBM controllers support the split-polling feature as a means of achieving higher throughput rates, even
when connected to standard legacy devices. The Express 8-Port Mux allows the split-polling feature to remain
enabled, with performance of up to 4 times greater than standard legacy 1-Mbps 5250 protocol.

The Express 8-Port Mux has 8 shielded RJ-45 port connections as well as a DB25 “direct connection,”
eliminating the need for the twinax “brick” and associated twinaxial cabling. The link between the two muxes
uses multimode fiber cable with ST connectors. It can operate in both point-to-point and multipoint ring
topologies, reducing hardware requirements by up to 50%. Other features include advanced noise filtering,
LED port diagnostics, configurable UTP pin assignments, and a field-replaceable wide-ranging power supply.

2.2 What the Package Should Include

Remove the packing material and check for the items below. If anything is missing or damaged, contact Black
Box at (724) 746-5500.

• (1) Express 8-Port Mux (includes a 100-to-240-VAC input external power supply, attached on the rear panel)

• (1) AC power cord (North American units only)

• This users’ manual

CAUTION

Do not apply power to any damaged component!

Содержание IC219A

Страница 1: ...746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION JUNE 2000 IC21...

Страница 2: ...rucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las in...

Страница 3: ...ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El...

Страница 4: ...HIS MANUAL ST is a registered trademark of AT T AS 400 and IBM are registered trademarks of International Business Machines Corporation Any other trademarks mentioned in this manual are acknowledged t...

Страница 5: ...cators 7 3 Configuration 8 3 1 Active Pair Setup 8 3 2 Configuration Switch Settings 9 3 3 Mode Description 10 3 4 Collapsed Rings 11 3 5 Connections 11 4 Installation 14 4 1 Host Side Multiplexor Ins...

Страница 6: ...6600 ft 2011 7 m Speed 1 or 2 Mbps depending on IBM 5250 protocol Connectors 8 RJ 45 1 DB25 M 1 pair of ST Indicators LEDs Power Port Activity Mode Peak Power Wavelength 820 nanometers Operating Temp...

Страница 7: ...roughput rates even when connected to standard legacy devices The Express 8 Port Mux allows the split polling feature to remain enabled with performance of up to 4 times greater than standard legacy 1...

Страница 8: ...l is detected or a system reset occurs The lower green LEDs are data activity indicators These LEDs activate when a signal is present Polling Group Connectors There are two polling groups Each polling...

Страница 9: ...adian Electrical Code 9 For your safety power outlets must be properly wired and grounded 10 Never attempt to service equipment connected to the data cable network or the grounded receptacle during an...

Страница 10: ...B25 is disconnected If the DB25 is selected the RJ 45 connectors are disconnected All jumper settings must be identical To reinstall the top cover tilt the top cover down and slide the top cover forwa...

Страница 11: ...xors are connected in series with fiber optic transmit to fiber optic receive they form a ring topology see the illustration below RX TX HOST PORT CONNECTIONS DEVICE CONNECTIONS MULTIPLEXOR MULTIPLEXO...

Страница 12: ...s Figure 3 2 Typical AS 400 Installation TX RX TX RX TX RX M D F TX RX IDF Intermediate Distribution Frame Main Distribution Frame Fiber optic patch panel Fiber optic jumpers Remote multiplexor 1 Remo...

Страница 13: ...A Polling group 1 Port and polling group assignments on the twinax brick for the new AS 400 WSC with split polling feature front view Mini Twinax Balun IC067A Mini Twinax Balun IC067A Mini Twinax Balu...

Страница 14: ...4 through 7 make up the other polling group The twinax brick detail illustrates a proper connection Figure 3 6 Typical System 3X Installation 62 5 micron multimode Express 8 Port Mux Stars Patch pane...

Страница 15: ...iguration switches on the rear panel of the host side Express 8 Port Mux as follows Switches 1 and 2 ON for a point to point application or Switch 1 ON and Switch 2 OFF for a ring application 2 The Ex...

Страница 16: ...ltimode fiber optic cable attached to the host side Multiplexor s TX to the device side Multiplexor s RX optical link connector located on the rear panel of the Express 8 Port Mux and connect the mult...

Страница 17: ...onnected with fiber optic jumpers Verify the application with a host port and a terminal 3 Search through the common problems and possible causes provided in this chapter The Express 8 Port Mux front...

Страница 18: ...matches the Express 8 Port Mux s pinout Verify that the host side balun s pinout polarity match the device side balun s pinout polarity Devices interfere with each other Verify that there is one host...

Страница 19: ...escription including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or ma...

Страница 20: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2000 Black Box Corporation All rights reserved...

Отзывы: