background image

Page 2

724-746-5500   |   blackbox.com

 

Basic Live Traffic Identifier

FEDERAL COMMUNICATIONS COMMISSION AND 

INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS

This equipment generates, uses, and can radiate radio-frequency energy,  
and if not installed and used properly, that is, in strict accordance with the  
manufacturer’s instructions, may cause inter ference to radio communication.  
It has been tested and found to comply with the limits for a Class A computing 
device in accordance with the specifications in Subpart B of Part 15 of FCC rules, 
which are designed to provide reasonable protection against such interference 
when the equipment is operated in a commercial environment. Operation of  
this equipment in a residential area is likely to cause interference, in which case 
the user at his own expense will be required to take whatever measures may be 
necessary to correct the interference.

Changes or modifications not expressly approved by the party responsible  
for compliance could void the user’s authority to operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise  
emis sion from digital apparatus set out in the Radio Interference Regulation  
of Industry Canada.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les 
limites applicables aux appareils numériques de la classe A prescrites dans le 
Règlement sur le brouillage radioélectrique publié par Industrie Canada.

Normas Oficiales Mexicanas (NOM) 

Electrical Safety Statement

INSTRUCCIONES DE SEGURIDAD

1.  Todas las instrucciones de seguridad y operación deberán ser leídas antes  

 

de que el aparato eléctrico sea operado.

2.  Las instrucciones de seguridad y operación deberán ser guardadas para  

referencia futura.

3.  Todas las advertencias en el aparato eléctrico y en sus instrucciones de  

 

operación deben ser respetadas.

4. Todas las instrucciones de operación y uso deben ser seguidas.

5.  El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la 

tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.

6.   El aparato eléctrico debe ser usado únicamente con carritos o pedestales  

 

 que sean recomendados por el fabricante. 

Содержание FOLTIB

Страница 1: ...tion Basic Live Traffic Identifier Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Customer Support Information FOLTIB ...

Страница 2: ...ould void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement su...

Страница 3: ...o como se indique en el aparato 12 Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atención a los contactos y receptáculos donde salen del aparato 14 El equipo eléctrico debe...

Страница 4: ... not short circuit the AC adapter charger terminal and the batteries Excessive electrical current may cause personal injury due to fumes electric shock or equipment damage Connect the AC power cord to the equipment and wall socket properly When you insert the AC plug make sure there is no dust or dirt on the terminals and both plugs are fully seated WARNING If the AC plug is not connected properly...

Страница 5: ...What s Included 7 3 Operation 8 4 Using the Basic Live Traffic Identifier 9 4 1 Display and Controls 9 4 1 1 Front Panel Board 9 4 1 2 Back and Side 11 4 2 Powering On the Unit 11 4 3 Detecting Traffic 13 4 4 Detecting Frequency 14 4 5 Signal Intensity 15 4 6 Self Calibrating 15 5 Maintenance 16 Appendix Troubleshooting 18 A 1 Calling Black Box 18 A 2 Shipping and Packaging 18 ...

Страница 6: ...elength Range 900 nm 1650 nm Table 1 1 Sensitivity minimum recognizable optical power intensity in the fiber Sensitivity 1310 nm typical 1550 nm typical Continuous wave 20 dBm 30 dBm 2 kHz modulated wave detection 10 dBm 18 dBm 1 kHz modulated wave detection 10 dBm 18 dBm 270 Hz modulated wave detection 10 dBm 18 dBm 1 2 General Specifications Temperature Tolerance Operating 14 to 122 F 10 to 50 C...

Страница 7: ...nd 2 kHz Use the FOLTIB with both 0 25 0 09 mm bare fiber and 3 mm jacketed fiber When testing jacketed fibers the slim design of the FOLTIB allows easier access to a splice tray where the amount of workspace is limited The clamping trigger fits the natural motion of the operator s hand The instrument is ruggedly constructed and reliable 2 2 What s Included Your package should include the followin...

Страница 8: ... to the FOLTIB If this happens replace the batteries with new ones To replace the batteries remove the battery plate on the back side of the unit with a Philips screwdriver Figure 3 1 Replacing the battery NOTES 1 Use 1 5 V alkaline batteries The low battery indicator may light if you use rechargeable batteries 2 To eliminate the possibility of acid leakage remove the batteries if the unit will no...

Страница 9: ...the Basic Live Traffic Identifier 4 Using the Basic Live Traffic Identifier 4 1 Display and Controls 4 1 1 Front Panel Board Figure 4 1 shows the front panel board Table 4 1 describes its components 1 2 3 4 5 6 7 8 9 10 11 Figure 4 1 Front panel board ...

Страница 10: ...icator Lights if the signal in the tested fiber is from right to left 5 Right traffic indicator Lights if the signal in the tested fiber is left to right 6 Signal intensity Shows the signal intensity level A higher inten sity means a stronger signal 7 2 kHz indicator Lights if the wave frequency is 2 kHz 8 1 kHz indicator Lights if the wave frequency is 1 kHz 9 270 Hz indicator Lights if the wave ...

Страница 11: ...ts components 1 Serial number 2 Clamping trigger 3 Battery plate Figure 4 2 Back and side view 4 2 Powering on the Unit Gently insert the tested fiber into the groove at the top of the identifier Pull the clamping trigger slowly to press the fiber against the optical assembly The identifier powers on when the detector plunger closes and the fiber is in the correct position See Figures 4 3 and 4 4 ...

Страница 12: ...n placing the fiber in the provided slot Do not force the fiber into the position Misaligning the fiber may induce optical losses above what the specification demonstrates Figure 4 3 Insert the tested fiber into the groove Figure 4 4 Press the fiber slowly against the optical assembly ...

Страница 13: ...nal a traffic indicator lights to show the direction left or right See Figures 4 5 and 4 6 Figure 4 5 Signal traveling right to left Figure 4 6 Signal traveling left to right When no signal is present or the signal to be tested is too weak for the identifier to detect the No Signal indicator lights See Figure 4 7 Figure 4 7 No signal indicator ...

Страница 14: ...sted fiber is carrying a 2 kHz 1 kHz or 270 Hz modulated wave the respective modulation indicator lights and the identifier makes a buzzing sound Figure 4 8 Modulation indicator NOTE The identifier might not recognize the frequency correctly if the signal is too weak or the frequency is not stable ...

Страница 15: ...al is stronger Figure 4 9 Signal intensity indicators 4 6 Self Calibrating The identifier might need to be adjusted if you haven t used it for while or if the temperature or light conditions change suddenly Change the plunger to the H 0 25 type pull the clamping trigger then press the Adjust key for less than two seconds to start the self calibration which lasts about 10 30 seconds When it finishe...

Страница 16: ...with cleaned Corning SMF 28TM SMF D pure non dispersion coated fiber If you use different brands or types of fiber with various coating colors the testing performance will be affected 2 Do not bend the fiber excessively This may cause the unit to misjudge traffic or might even break the fiber Figure 5 1 Figure 5 2 ...

Страница 17: ...eiver clean and use cleaning oil when testing bare fiber to achieve the best performance 4 To clean the optical assembly remove the clamp and gently clean the prism and optical windows using cleaning pads and cleaning oil Do not immerse the plunger assembly in alcohol Figure 5 3 ...

Страница 18: ...fficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse A 2 Shipping and Packaging If you need to transport or ship your Basic Live Traffic Identifier Package it carefully We recommend th...

Страница 19: ...Page 19 724 746 5500 blackbox com NOTES ...

Страница 20: ... About Black Box Black Box Network Services is your source for more than 118 000 networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 20 seconds or less Copyright 2010 All rights reserved FOLTIB rev 1 ...

Отзывы: