Test Modes

The Compact mDSL Modem offers a proprietary Remote

Loopback test modes, plus a built-in V.52 BER test pattern generator
to evaluate the communication status between units.  Activate this test
mode by toggling the Test Mode Switch on the front panel of the unit.  

Overview

Figure 10 below shows the major elements used in the loop-back

and 511 pattern tests available in the Compact mDSL Modem. Each
block has several functions. Following Figure 10 are descriptions of the
elements during Test Modes.

Framer

The framer determines the status of the line. In
normal operation the framer transmits and
expects to receive framed packets from the far
end. If the framer receives framed packets from
the far end, the DSL Link LED will turn on. If
framed packets are not received, the DSL Link
LED will turn off. The restart procedure uses this
information to determine if a valid connection is
made (cable disconnect, poor cable quality, etc).
In normal Data Mode, if the box receives 4 sec-
onds of unframed packets it will restart the box
and begin trying to re-establish a connection 
with the the remote Compact mDSL Modem.
The distinction between framed packets and
unframed packets becomes important when we
discuss the Pattern Generator.

Pattern Gen/Det

This part of the Processor generates and
detects the 511/511E patterns. When transmit-
ting 511 patterns, the information is unframed
(because it originates after the framer) and is

17

Compact mDSL Modem  

18

Compact mDSL Modem  

intended to be evaluated only by another Processor.
If the units are transmitting data and the pattern gen-
erator is enabled on one end of the link, the far end
will begin receiving unframed packets and assume
that the line has gone down. During test modes, the
pattern generator is forced to time out before it can
cause the DSL link to go down. 

Loop Control

This part of the Processor is used to control Remote
Loopback test mode. In a Remote Loop, the
511/511/Edata is looped back to the line and to the
remote unit over the DSL span.

Restart Procedure

The restart procedure is in place to allow the

and Time Outs

units to re-establish a connection after the framer
begins seeing unframed packets. The Test Mode
Timing Chart below shows the amount of time the
framer must see consecutive unframed packets
before the unit will restart and try to establish a new
line connection. The reason that there are different
Restart Times will become apparent after reading the
rest of the document. The 511/511E Time Out shown
refers to the amount of time the 511/511E pattern will
be valid. At the end of this time the pattern will auto-
matically turn itself off and the normal data path will
be re-established. The ER led will flash indicating to
the user that the test has timed out. The ER led will
stop flashing once the 511/511E switch is placed into
the normal position.

Symbol Indicators

This symbol designates the origination or the termi-
nation of a data path. The direction of the arrow con-
nected distinguish the two data paths.

This symbol designates an invalid data path. If there
is data present it should be ignored.

Pattern

Gen/Det

Loop

Control

Loop

Control

Pattern

Gen/Det

Processor

Processor

Framer

Framer

DSL

Span

Figure 10: 

Block Diagram- Two Compact mDSL Modems Communicating Over the DSL Span

                          Test Mode Timing

Item

Elapsed Time (seconds)

Start Up

50

Data Mode

4

511/511E Generator Enabled 60 (The generator will stop after 45 seconds.)

Remote End of an RDL

60

511/511E Time Out

45 (The pattern generator will automatically turn

off after 45 seconds. The ER LED will flash until

the user turns off the 511/511E switch.)

Содержание Compact mDSL Modem

Страница 1: ...8 965 6000 0118 965 5100 0118 965 5001 464 Basingstoke Road Reading Berkshire RG2 0QN www blackbox co uk Compact mDSL Modem 464 Basingstoke Road Reading Berkshire RG2 0QN Copyright 2000 Black Box Cata...

Страница 2: ...to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection from such interf...

Страница 3: ...e packets based on its IP address Figure 1 shows a typical Cisco router with a serial interface configured as a PPP Half Bridge The router serial interface uses a remote device that supports PPP bridg...

Страница 4: ...ciated Cisco configuration will set serial interface s0 to accommodate half bridging for the above example Authentication is optional under PPP In a point to point leased line link incoming customer f...

Страница 5: ...SL Modem 7 Configuring the Hardware DIP Switches The Compact mDSL Modem has two sets of eight DIP switches which allow configuration for a wide variety of applications This sec tion describes switch l...

Страница 6: ...tilization on the local domain on an Ethernet LAN runs typically between 15 to 20 1 5Mbps to 2Mbps of the maximum bit rate of 10Mbps Traffic between LANs typically runs even lower between 2 to 7 200kb...

Страница 7: ...pair interface the 10BaseT Ethernet Interface and the power source This section describes these connections Connecting DSL Interface The MDU9705A 10BT supports communication between 10BaseT Hubs or Wo...

Страница 8: ...Modem by means of a barrel jack on the rear panel Many international power cords are available for the universal power supply The Compact mDSL Modem powers up as soon as it is plugged into an AC outle...

Страница 9: ...ompact mDSL Modem 16 Compact mDSL Modem CRC 9 pulses Detected LAN receive frame s too large 10 pulses Detected LAN receive frame s not octet aligned 11 pulses Detected LAN receive frame s with bad CRC...

Страница 10: ...has gone down During test modes the pattern generator is forced to time out before it can cause the DSL link to go down Loop Control This part of the Processor is used to control Remote Loopback test...

Страница 11: ...ing the pattern The ER led will begin blinking until the user turns off the 511 511E switch Using the V 52 BER Test Pattern Generator To use the V 52 BER tests in conjunction with the Remote Digital L...

Страница 12: ...est Mode Enabled Configuration Externally accessible dip switches or SNMP HTTP managed through MDU9700C Power 5V External desk top power supply 100 240VAC 50 60 Hz Universal Input 10W or 48 VDC Compli...

Страница 13: ...36 7348 www black box xh www blackbox com Netherlands Mexico Black Box Datacom BV Black Box De Mexico S A de C V Tel 03032417799 Tel 05 420 0100 Fax 0302414746 Fax 05 420 0123 www blackbox nl www blac...

Отзывы: