TOKEN RING FIBER EXTENDERS
22
Power
LED
Copper
LED
Fiber
LED
Rx
Alarm
Mode
Condition
On
Off
Off
Off
LOBE ACL
ON CONC
LCL112A-TR can see far
end device, however
LCL112A-TR is not inserted
on either interface. Check
that the remote end station is
powered up, its drivers have
loaded correctly
crossover cable is used.
On
D/C
Off
Off
TRUNK
MODE ACL
ON CONC
OR
STATION
Fiber link not operating
correctly.
1) Check Tx connection to
remote LCL112A-TR is
powered up.
2) Check switch settings for
required operating mode.
On
Off
On
Off
TRUNK
ACL ON
CONC
(connector
to MAU lobe
port)
Fiber link is
inserted,
however fault exists on
local copper link to MAU.
Check cabling and MAU
operation, and that a
crossover cable has been
used between
the
LCL112A-TR and
the
MAU.
On
Off
On
Off
TRUNK
ACL ON
NODE
(connected
to a station)
Fiber link is
inserted,
however copper link is not
inserted. There are
two
possible causes:
1) The PC is powered off.
2) The link between the PC
and LCL112A-TR is faulty:
Check that a straight
through patch cable is
being used.