Troubleshooting

Sometimes, depending on the speed of the management PC and/or
its video card, the bandwidth displays in the Port A and Port B win-
dows in 

iView

may not update when switching between windows 

quickly.  To update the display, click the 

Refresh

button found in 

the upper-right corner of the window.

The

iView

online help file requires Internet Explorer™ 4.0 service 

pack 2 or higher.

Should you encounter further difficulties, please contact Black Box 

technical support.

General Information

B

L A C K

B

O X

T

E C H N I C A L

S

U P P O R T

Order toll-free in the U.S.:

Call 877-877-BBOX (outside U.S. call 724-746-5500) 

FREE technical support, 24 hours a day, 7 days a week: 

Call:

724-746-5500 

Fax:

724-746-0746

Mail order:

Black Box Corporation, 1000 Park Drive, 

Lawrence, PA 15055-1018

Web site:

www.blackbox.com

E-mail

: [email protected]

S

P E C I F I C A T I O N S

Environmental

Operating Temperature:  32° - 104° F (0° - 40° C)
Storage Temperature:  0° - 160° F (-20° - 70° C)
Humidity:  5 - 95% (non-condensing)

Electrical

Module: 5V ±5%, 0.5 Amp. (typical)
Configured: 100-240VAC ±10%, 0.2/0.1A

BandwidthManager Configuration

To configure 

BandwidthManager

, press 

Space

at the 

Main Configuration

Screen

, then type 

bw

.  This will enter the configuration program for

BandwidthManager

.  To navigate in this program, press 

Z

to move down, 

W

to move up, 

A

to move left, and 

D

to move right.  Pressing 

Space

toggles

between the 

Bandwidth Control

section and the 

Duplex Mode

section.

Pressing 

Q

exits the program.

To edit the data rate for each port, you can choose one of twelve prede-

fined rates by moving the cursor to the rate you desire and pressing the 

S

or 

Enter

key, or enter your own rate by choosing 

Custom

.

To choose

Custom

, move the cursor to 

Custom

, then press the 

S

key.  Enter a rate

(between 64 bits/sec to 10,000,000 bits/sec in 1 bit/sec increments) and
then press 

Enter

.  You can choose a rate for both 

BandwidthManager

ports

(from Port A to Port B and from Port B to Port A).  Exit the program by
pressing the 

Q

key.

To change the Duplex setting, 

Space

to toggle to the Duplex Setting sec-

tion when, then press 

S

or 

Enter

to switch between Half- and Full-Duplex.

The default setting for duplex on Ports A and B is Half-Duplex.  Duplex can
also be adjusted through 

iView 

by clicking on either 

Port

tab.

Assigning IP Information

To modify the Saved Parameter Values (i.e., assign IP address and subnet

mask), press 

I

.  You will be instructed to enter the IP address and subnet

mask for the connected device.  Press 

Enter

after each.  You may also

assign a default gateway, if desired (press 

Enter

to skip).  When finished,

press 

Enter

, then type “

Reboot

” for changes to take effect.  The Saved

Values and Current Values should now both display the changes made
(e.g., new IP address and subnet mask).

9

4

N O T E

Because the Delete key does not work on VT-100 terminal emulators,
use the 

F2

key instead to perform Delete.

N O T E

You must reboot after making any modifications to the Saved Values
or your changes will not take effect.  To reboot, type the word

Reboot

” (no quote marks) at the prompt on the main configuration

screen, or turn the device’s power OFF then ON again.