1.1 SPECIFICATIONS

Approvals: 

CE, FCC

Operating Temperature:  32 to 104°F (0 to 40°C)

1.2 OPTIONS

The following options are available:

•  Central power hub unit with 8 output ports 

Part number: ACR1000-CPH8R-R2

•  Central power hub unit with 16 output ports 

Part number: ACR1000-CPH16R-R2

•  5VDC converter dongle with 6.5' (2m) lead 

Part number: ACR1000-12V5-CBL2M

•  12VDC link cable 6.5' (2m) 

 

 

Part number: ACR1000-3PL-CBL2M

•  Secondary power module 

 

 

Part number: ACR1000-CPH-PS-R2

CHAPTER 2: WELCOME

CHAPTER 1: SPECIFICATIONS

2.1 INTRODUCTION

Thank you for choosing the Black Box Central Power Hub. 
In tune with your network, as KVM systems expand so too 
do their requirements for the reliable supply of power. 
While individual Black Box power adaptors perform well, 
as devices proliferate they can become unwieldy and diffi-
cult to manage. Central Power Hub provides the next step 
in terms of efficiency, reliability and power management. 

The heart of the Central Power Hub system is a modular 
chassis which occupies a 1U 19” rack slot. Arranged along 
its rear panel are eight or sixteen low voltage output ports. 
These ports are then linked via cables and/or 

Converter 

dongles 

to the devices that require power. Each output 

has a nominal power rating of 30W. 

The overall power is generated within the main chassis by 
either one or two plug-in 495W power modules. Adding 
the optional second power module provides redundancy 
for mission critical installations. During normal operation, 
the overall load is shared between the twin power mod-
ules, with the full load transferring instantly to one if the 
mains supply to the other should fail.  

Содержание ACR1000-CPH-PS-R2

Страница 1: ...USER GUIDE ACR1000 CPH8R R2 ACR1000 CPH16R R2 ACR1000 CPH PS R2 CENTRAL POWER HUB 24 7 TECHNICAL SUPPORT AT 1 877 877 2269 OR VISIT BLACKBOX COM...

Страница 2: ...emarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners We re here to help If you have any questions about your applicat...

Страница 3: ...case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for co...

Страница 4: ...reros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufa...

Страница 5: ...erter dongles 8 3 3 Connections 9 3 4 Fitting removing a power module 11 3 5 Network connection 12 CHAPTER 4 CONFIGURATION 13 4 1 Accessing the management application 13 4 2 The Status Control page 14...

Страница 6: ...or the reliable supply of power While individual Black Box power adaptors perform well as devices proliferate they can become unwieldy and diffi cult to manage Central Power Hub provides the next step...

Страница 7: ...t either via the front panel CLEAR button or the management application The other power output ports will remain unaffected dur ing this period 5V overload protection Where an optional converter dongl...

Страница 8: ...See below for details Consult the precautions listed within the Safety information section 3 2 MOUNTING CONVERTER DONGLES For each device that requires a 5VDC supply 12VDC devices require only a sim p...

Страница 9: ...g at one end of the ACR1000 3PL CBL2M cable to the power input socket of the device the lead is 2m 6 5 feet in length 2 Connect the locking 3 pin plug at the other end of the cable to one of the power...

Страница 10: ...e close to the device that will be pow ered An optional elongated rack bracket is available to allow the dongle to be mounted immediately behind the device 2 Connect the 2 5mm power jack of the dongle...

Страница 11: ...s to hold the module in place 3 4 2 TO REMOVE A POWER MODULE Note Power modules are hot pluggable i e while power is applied to the other module be sure to observe safe working practices and anti stat...

Страница 12: ...Power Hub allows remote monitoring and control via a standard network connection 3 5 1 TO CONNECT TO A NETWORK 1 Use a screened patch cable cross over or straight connections are both sup ported to l...

Страница 13: ...a temporary connection see below 2 Run a web browser on your computer and enter the IP address of the Central Power Hub The default IP address setting is 192 168 1 22 3 If requested enter your usernam...

Страница 14: ...u can monitor name and control each output port individually Key metrics for the single or dual power module s including the temperatures cooling fan speeds mains input and low voltage output currents...

Страница 15: ...Power Output section As appropriate click either the ALL ON or ALL OFF but ton 2 Click OK to confirm your choice in the subsequent popup Note When the ALL ON button is pressed the individual ports wi...

Страница 16: ...ed to the unit before the power modules apply their full supply to the Central Power Hub chassis This feature is useful when multiple Central Power Hub units are fed from the same mains power feed By...

Страница 17: ...tral Power Hub will use DHCP Dynamic Host Configuration Protocol to automatically determine all network settings and all other options in this page will be grayed out When unticked use the other optio...

Страница 18: ...within the General configuration page is ticked 4 5 1 TO ADD A NEW USER 1 Enter a User Name and Password and then Confirm password in the labeled fields Note The User Name and Password fields accept...

Страница 19: ...the operation of the Central Power Hub unit equivalent to a cold reboot as if power to it had been removed and restored All power outputs will be removed and then restored in a staggered manner define...

Страница 20: ...ORY RESET 1 Click the Factory Reset button 2 Click OK to confirm your choice in the subsequent popup 4 6 3 FIRMWARE UPDATE This option will perform an update to the firmware contained within the logic...

Страница 21: ...ashing One or both of the power modules is an invalid type OVLD On An overload condition has been detected on one or more of the 12V output ports The port will have powered down After recti fying the...

Страница 22: ...between it and the Central Power Hub 2 Depending on where the trip was made you will see different results If the Central Power Hub electronic short protection circuit responded the front panel OVLD...

Страница 23: ...peration of the Central Power Hub unit equivalent to a cold reboot All power outputs will be removed and then restored in a staggered manner as defined within the management application No configurati...

Страница 24: ...ering Replace the power adapter with a manufacturer approved type only Do not use the power adapter if the power adapter case becomes damaged cracked or broken or if you suspect that it is not oper at...

Страница 25: ...COPYRIGHT 2021 BLACK BOX CORPORATION ALL RIGHTS RESERVED NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 877 877 2269 blackbox com ACR1000 rev 1 0...

Отзывы: