Terminal Server User Guide
Diagnostics
Page 189
Diagnostics
Entering the Diagnostic Menu
1. Connect a serial terminal (configured for 9600,n,8,1) to port 1 of the server.
2. Power on the server and press "<cntrl> B" on the terminal five times in succession while
the unit LEDs are flashing (the firmware decompression phase).
This causes the following menu to be displayed on the terminal:
1. Self-test.
2. Diagnostics.
3. Monitor.
4. Download.
5. Reset.
q Quit and boot server firmware.
Self-test
This is an option intended for use at the factory and by repair centres, all of the functionality
provided by this test is available by selecting the Diagnostics option. It is recommended that
you do not select the Self-test option.
Monitor
This option allows a number of settings to be made and allows read and write operations
directly into specified memory locations. Again it is not intended for use outside of the factory
or repair centres.
Note
If you have an older unit with a reset button, to display the Diagnostic Menu proceed as
follows;
a. Press and hold down the reset button.
b. Power on your Terminal Server server unit.
The Diagnostic menu now appears.
c. Release the reset button.