OPERATING INSTRUCTIONS

Ensure that all installation and operating instructions and safety 
precautions are understood and carefully followed by anyone
installing or using the charger. Follow the steps outlined in “Important
Safety Instructions” at the front of this manual.  
Charge Rate Selection

After charger clamps are correctly connected, plug in the charger to a 120 volt AC
outlet and the charger will show a circulating pattern on the Digital Display, indicating
power has been applied. Select the proper charge current rate based on battery size.
Press the 4/10/20/40 AMP button and the charger will begin charging at 4 amps.
Pressing the 4/10/20/40 AMP button again will advance the charge rate to 10
amps, again to 20 amps, and again to 40 amps. Pressing the switch again will turn
OFF the charger output and the display will show “000.”

Note:

The only time the selected charge rate does not display at the full selected rate
is when the battery is nearly full and charging at either step two or three. The
display will be showing a reduced charge rate. To return to 2A, press the
2/20/40 AMP button. When the battery is fully charged, the charging complete
and “FUL” is displayed on the Digital Display.

WARNING

If Digital Display shows “F02”, the connection to the battery terminals
is bad. Follow the steps outlined in “Important Safety Instructions”
at the front of this manual to disconnect, clean battery terminals,
then reconnect.
If Digital Display shows “F06”, the Red (POSITIVE) and Black
(NEGATIVE) clamps are incorrectly connected to battery terminals.
Follow the steps outlined in “Important Safety Instructions” at the
front of this manual to disconnect, then reconnect in correct polarity.

Charging the Battery

1. Press Battery Type selector until desired battery type LED lights.

Note:

The default selection is “GEL” type battery.

2. Press 4/10/20/40 AMP button to begin charging at the 4 amp rate; the unit

sounds a beep and the charging current LED lights. The charger starts charging
at 4 amp rate automatically if 4/10/20/40 AMP button is not pressed within 3
minutes after applying AC power.
If the Display on the charger varies between “F03” and the amp rate, the battery
is sulfated and the charger is trying to give it some charge. If after approximately
2 hours the display just shows “F03”, then the battery will not charge.
Charger occasionally sounds a beep and displays “0.0” during self-test or
charging stage changes.

3. Pressing the 4/10/20/40 AMP button again advances charging rate to 10

amps, pressing once more advances charging rate to 20 amps, and again to 40
amps. (Pressing the button again will turn OFF the charger output and the Display
will show “000”.) This selection and actual battery charge rate are monitored by
the microprocessor, and the unit will stop charging if the selected rate is too fast
or too slow for battery size or condition.
As the battery nears full charge capacity, the unit’s output will automatically drop
to a lower charge rate.

4

INDICATOR:

Large (.375”) 3-Character Digital Display

in the upper left of the control panel

indicates the various conditions and/or status codes:

Status Codes

are described in the following chart and on the back of charger.

CONTROL PANEL LED INDICATORS:

WET — 

lights when battery type selector is on WET battery type

GEL —

lights when battery type selector is on GEL battery type

AGM — 

lights when battery type selector is on AGM battery type. 

Float Charge —

lights when automatic charge monitoring is active. This feature

allows a battery to maintain its charge over long periods of non-use. If there is any
loss of power to the charger once power is restored charger will automatically return
to the default settings. Battery selector type would be “GEL”.

Battery Voltage —

lights when battery voltage is displayed. 

Alternator Good — 

lights when load or not load checks show the alternator is

keeping up with the electrical load.
BUTTON (TO THE RIGHT OF LEDS):

Equalize — 

a recessed button used to start the equalization process.

AC POWER INDICATOR - 

When connected to an AC outlet, digital display shows circulating pattern to

indicate power is on. Disconnect charger after use.

FAULT CODES

OPERATION CODES

F01

F02

F03

F04

F05
F06
F07

000
FUL

INTERNAL SHORTED CELL BATTERY - 

Cannot be charged. Have battery checked by certified auto service center.

 

EXCESSIVE LOAD ON BATTERY WHILE CHARGING - 

Check load.

BAD BATTERY CONNECTION - 

Check battery connection.

BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE - 

Have battery checked by certified auto service center.

BATTERY RECONDITIONING - 

(The letters 

DES

 will display for the first 3 seconds.)

INTERNAL OPEN CELL - 

Have battery checked by certified auto service center.

SULFATED CONDITION - 

Battery needs to be reconditioned. See manual.

OVERHEATED CONDITION - 

Disconnect charger and allow to cool for 30 min., check for ample ventilation.

REVERSE POLARITY

ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE

ALTERNATOR VOLTAGE CHECK
CHARGER STANDBY
BATTERY FULLY CHARGED

OVERTIME CONDITION - 

Battery will not accept a charge after 18 hours of continuous charging. Battery may have 

internal damage. Have battery checked by certified auto center.

BATTERY CHARGE RATE IS SET TOO LOW -

 Set charger to higher charge rate. See manual.

VEC1093DBD_Manual_050205  5/5/05  6:32 PM  Page 4

Содержание Smart Battery Charger

Страница 1: ...hipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire flood and Acts of God If your problem is not covered by this warranty call Technical Support at 800 618 5178 for general repair information and charges if applicable You may also contact us through our website at www vectormfg com STATE LAW RIGHTS...

Страница 2: ...NG NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary markings on these products...

Страница 3: ...ing 9 See operating instructions for length of charge information Follow these steps when the battery has been removed from a vehicle A spark near the battery may cause an explosion To reduce risk of a spark near the battery 1 Check polarity of battery posts The POSITIVE post marked POS P usually has a larger diameter than the NEGATIVE battery post marked NEG N 2 Attach a 24 inch minimum length 6 ...

Страница 4: ... possible charge at a constant safe predetermined voltage During this phase the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer At the end of Stage 2 the charger will automatically move into Stage 3 charge mode Stage Three Top Off Charge voltage is automatically maintained and reduced to a predetermine...

Страница 5: ...ore advances charging rate to 20 amps and again to 40 amps Pressing the button again will turn OFF the charger output and the Display will show 000 This selection and actual battery charge rate are monitored by the microprocessor and the unit will stop charging if the selected rate is too fast or too slow for battery size or condition As the battery nears full charge capacity the unit s output wil...

Страница 6: ...ate charge most of the lead sulfate is dissolved and the plates are free of this insulation If a battery remains in a discharged condition over a longer period of time the lead sulfate changes to a hard crystalline form making a full charge difficult to achieve Reconditioning may save a sulfated battery 6 Pressing the 4 10 20 40 AMP button repeatedly advances to standby mode the unit sounds a beep...

Страница 7: ...ONDITION Mode Observe the Digital Display for any codes This initial charge will check the battery for shorted cells F01 open cells F03 or battery too low to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Remove or disconnect the vehicle s battery when reconditioning 1 Make sure the charger is in initiation state with...

Страница 8: ...oning and equalizing we recommend taking your battery to a certified automotive service center for evaluation F04 Overtime Condition Appears when charging time exceeds 18 hours You may be using a charge current rate too low for a large battery Select higher charge rate to charge the battery F05 Overheated Condition The ventilation grill that prevents the air from flowing in and out of the charger ...

Отзывы: