3
SyMBOLS
The label on your tool may include the following symbols. The symbols and their definitions are as follows:
V ..................volts
A ...................amperes
Hz ................hertz
W ..................watts
min ..............minutes
................alternating current
.............direct current
no .................no load speed
................Class I Construction
..................earthing terminal
(grounded)
................safety alert symbol
................Class II Construction
.../min or rpm...revolutions or
(double insulated)
reciprocation per minute
............Read instruction manual before use
..................Use proper respiratory protection
................Use proper eye protection
..................Use proper hearing protection
•
When using an extension cord, be
sure to use one heavy enough to carry
the current your product will draw. An
undersized cord will cause a drop in line
voltage resulting in loss of power and
overheating. The following table shows
the correct size to use depending on
cord length and nameplate ampere
rating. If in doubt, use the next heavier
gauge. The smaller the gauge number,
the heavier the cord.
SAVE ThESE INSTRUCTIONS
OPERATING INSTRUCTIONS
wARNING
:
Shock hazard.
Under no circumstances should this product be used near water.
wARNING
:
Risk of lacerations or burns.
Do not touch work piece or accessory
immediately after operating the tool. They can become very hot. Handle carefully. Always allow
accessories and work piece to cool before handling.
wARNING
:
To reduce the risk of injury
,
turn off and remove battery from tool or disconnect
plug from power source before making any adjustments or removing or installing attachments or
accessories. Remove any accessory from the attachment before removing or installing the attachment.
NOTE:
Refer to Power Unit instruction manual before operating this tool for all safety warnings
and details on installing and removing attachments.
Minimum Gauge for Cord Sets
Volts
Total Length of Cord in feet
120V
0-25
26-50
51-100
101-150
(0-7,6m) (7,6-15,2m) (15,2-30,4m) (30,4-45,7m)
240V
0-50
51-100 101-200
201-300
(0-15,2m) (15,2-30,4m) (30,4-60,9m) (60,9-91,4m)
Ampere Rating
More Not more
American Wire Gauge
Than Than
0 - 6
18
16
16
14
6 - 10
18
16
14
12
10 - 12
16
16
14
12
12 - 16
14
12
Not Recommended
fUNCTIONAL DESCRIPTION
1. Hammer drill/screwdriver attachment
2. Torque adjustment collar
3. Keyless chuck
4. Two gear shifter
Not Show:
Double-ended bit tip
1/4” Twist bit
1/4” Masonry bit
1
2
3
4
Содержание MATRIX BDCMTHD
Страница 23: ...23 ...