background image

Page 6

SAFETY INFORMATION

LCDI POWER CORD AND PLUG 

  

This air conditioner is equipped with an LCDI (Leakage Current 

Detection and Interruption) power cord that is required by UL. This 

power supply cord contains state-of-the-art electronics that sense 
leakage current. If the cord is damaged and leakage occurs, power will 
be disconnected from the unit.

The test and reset buttons on the LCDI Plug are used to check if the 
plug is functioning properly.

WARNING:

 Test LCDI before each use.

To test the plug:

1. Plug power cord into a grounded 3 prong outlet.

2. Press RESET (on some units a green light will turn on).

3.  Press the TEST button, the circuit should trip and cut all power to the air 

conditioner(on some units green light may turn off).

4.  Press the RESET button for use. You will hear a click and the A/C is ready 

for use. 

5.  The power supply cord must be replaced if it fails to trip when the TEST 

button is pressed and the unit fails to reset.

NOTES:  

•  Do not use this device to turn the unit on or off.
•  Always make sure the reset button is pushed in for correct operation

•  WARNING: 

•  The power supply cord must be replaced if it  

fails to reset when either the test button is  
pushed, or it cannot be reset. 

•  If power supply cord is damaged, it cannot  

be repaired.

•  It must be replaced by one obtained from  

the product manufacturer.

WARNING – RISK OF FIRE

• It is important the plug fits tightly into the wall outlet. 
• If the plug does not fit securely and appears loose, it should not be used. 

•Have a licensed electrician replace the receptacle.

Содержание BPT05WTBA

Страница 1: ...nce a problem with your BLACK DECKER purchase go to www blackanddecker com instantanswers If you can t find the answer or do not have access to the Internet call 844 299 0879 from 10 30 a m to 6 30 p m EST Mon Fri to speak with an agent Please have the catalog number available when you call SAVE THIS MANUAL FOR FUTURE REFERENCE CATALOG NUMBER BPT05WTBA BPT06WTB BPT07WTB ...

Страница 2: ...rchase PRODUCT REGISTRATION CONTENTS SAFETY INFORMATION Important Safety Instructions 3 4 Grounding Instructions 5 LCDI Power Cord and Plug 6 Safety Guidelines 8 SET UP USE Parts Features 9 Specifications 10 Installation Guide 10 Window Slider Kit Installation 11 Exhaust Hose Installation 12 Control Panel 13 Operating from the Control Panel 13 14 Operating from the Remote Control 15 21 Water Drain...

Страница 3: ...mbustible gases or where the atmosphere is oily or sulphurous Avoid any chemical coming in contact with your air conditioner 8 Do not place any object on the top of the unit 9 Never operate the air conditioner without filters in place 10 Do not use the air conditioner near a bathtub shower or wash basin 11 This appliance is not intended for use by persons including children with reduced physical s...

Страница 4: ...on the exterior of the battery Doing so may cause the battery to short leak fluid overheat or explode 10 Do not drop throw or expose the battery to extreme impact Doing so may cause the battery to leak fluid overheat or explode 11 Do not alter the shape of the battery If the insulation or safety valve is damaged the battery may leak fluid overheat or explode 12 Immediately remove batteries when th...

Страница 5: ... or without yellow stripes is the equipment grounding conductor If repair or replacement of the cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or service person if the grounding instructions are not completely understood or if in doubt as to whether the appliance is properly grounded Do not modify the plug connected t...

Страница 6: ... all power to the air conditioner on some units green light may turn off 4 Press the RESET button for use You will hear a click and the A C is ready for use 5 The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset NOTES Do not use this device to turn the unit on or off Always make sure the reset button is pushed in for correct operati...

Страница 7: ...ner is knocked over during use turn off the unit and unplug from the power supply immediately Do not operate your air conditioner in a wet room such as a bathroom or laundry room Do not touch the unit with wet or damp hands or when barefoot Do not press the buttons on the control panel with anything other than your fingers Do not remove any fixed covers Never use this appliance if it is not workin...

Страница 8: ...he air conditioner must be operated within the temperature range indicated below NOTE Unit performance may be affected when in use outside of these operating temperatures MODE ROOM TEMPERATURE COOL 64 F 18 C 95 F 35 C DEHUMIDIFY 64 F 18 C 95 F 35 C ...

Страница 9: ...ification Drain Air Exhaust Hose Housing Condensation Drain Plug Control Panel and Remote Control Sensor Air Exhaust Hose Hose Outlet Hose Inlet Remote Control Window Bracket Drip Pan Foam Seal SET UP USE Locking Screw Drain Hose 3 3 feet long 0 5 inch diameter 2 pcs 1 pc Page 9 ...

Страница 10: ...trong enough to support the unit The unit has casters to aid placement but it should be rolled on smooth flat surfaces Use caution when rolling on carpet surfaces Do not attempt to roll the unit over objects The unit must be placed within reach of a properly rated grounded socket Never place any obstacles around the air inlet or outlet of the unit Allow 12 inches to 36 inches of space from the wal...

Страница 11: ...SH SLIDING CASEMENT WINDOW INSTALLATION 1 Cut the foam seal adhesive type to the proper length and attach it to the window sash 2 Attach the window slider kit to the window sash Adjust the length of the window slider kit according to the width of window Shorten the adjustable window kit if the width of window is less than 20 5 3 Cut the foam seal adhesive type to the proper length and attach it on...

Страница 12: ...able air conditioner 1 Align Arrow of hose inlet and hose Turn either clockwise or counterclockwise to secure Fig 1 2 Align arrow of hose outlet and hose Turn either clockwise or counterclockwise to secure Fig 2 3 Attach the hose inlet onto the back of the unit Fig 3 4 Affix the hose outlet into the window slider kit and seal Fig 4 5 NOTE The exhaust hose can be compressed or extended moderately b...

Страница 13: ... function active when it was turned off will appear Never turn the air conditioner off by unplugging from the outlet Always press the button then wait for a few minutes before unplugging This allows the appliance to perform a cycle of checks to verify operation Note Before pressing Power On button make sure the condensate drain plug in the rear of the unit is securely in place to avoid any leaking...

Страница 14: ... in spring and autumn during rainy spells or in damp rooms etc Keep window and door closed for the best dehumidifying effect Exhaust hose attachment is not required to reduce humidity however it is recommended in very humid rooms so the warm air can be exhausted outside DRAINING IN DEHUMIDIFICATION MODE It is recommended that the dehumidification drain and drain hose can be used for continuous dra...

Страница 15: ...for a month or longer Do not attempt to recharge the batteries Both batteries should be replaced at the same time Do not dispose of the batteries in a fire as they man explode Point the remote control at the receiver on the appliance The remote control must be no more than 7 meters away from the appliance without obstacle between the remote control and the receiver The remote control must be handl...

Страница 16: ...sed to select the HIGH MED LOW or AUTO fan speed FUNCTION BUTTON Access FOLLOW ME or TURBO functions TIMER BUTTON Used to set a delay start or shut down time SLEEP BUTTON Gradually increase the temperature in COOL mode C F SELECTOR BUTTON Select Fahrenheit or Celsius Fan Remote Signal Power Button Increase Decrease Sleep Button Timer Button Child Lock Follow Me Turbo Function Button C F Selector T...

Страница 17: ...ol will illuminate on the LED display to indicate which mode is selected COOL Select the target temperature 64 F 90 F 18 C 32 C by pressing the or buttons until the desired temperature is displayed on the LED screen Press the Fan Speed Button to select Low Medium High or Auto Speed SET UP USE LED Display Indicators Cooling mode Fan speed Dehumidify mode Auto speed Fan mode Child lock Timer on Time...

Страница 18: ... FULL When the water level reaches a predetermined level will be indicated on the display The unit will have to be drained NOTE Refer to Water Drainage section page 22 In this mode fan speed is selected automatically by the appliance and can not be set manually FAN Press the Fan Speed Button to select Low Medium or High Speed FUNCTION BUTTON Press the to access FOLLOW ME and TURBO functions TURBO ...

Страница 19: ... allowing for the precise temperature control at its location To activate the Follow Me function point the remote control towards the appliance and press the FUNCTION button Press either the OR button until the FOLLOW ME symbol flashes on the LED screen Press the Menu button The FOLLOW ME will stop flashing and illuminate on the LED screen The remote will display the actual temperature at its loca...

Страница 20: ... the LED screen To cancel the programmed start up press the button again or the button The symbol will not be illuminated on the LED screen PROGRAMMING SHUT DOWN With the appliance ON Press the button twice the LED screen will display hours the symbol and symbol will flash Press the or button to set the time when you want the appliance to shut down using the buttons from 30 minutes to 24 hours Pre...

Страница 21: ...utton then you can select the unit of temperature from Fahrenheit or Celsius NOTE This will indicate an E momentarily when battery is installed It will automatically change to F and display Fahrenheit CHILD LOCK This function is used to prevent children from inadvertently changing the settings by pressing the remote control buttons Press and hold the and buttons simultaneously for at least 3 secon...

Страница 22: ...a drain area over your basement floor or drip pan not included Remove the bottom drain cap Let the water drain away and replace the drain cap Restart the machine until the symbol disappears If the error repeats call for service NOTE Be sure to reinstall the bottom drain plug before using the unit Continuous Draining for Cooling Mode Unplug the unit from the power source Remove the bottom drain cap...

Страница 23: ...ollect the water Connect the drain hose supplied as shown in the diagram The water can be continuously drained through the hose into a floor drain or bucket Turn on the unit NOTE The supplied drain hose can be substituted with a standard garden hose for middle drainage only WAIT 3 MINUTES BEFORE RESUMING OPERATION After the unit has stopped it cannot be restarted for 3 minutes Operation will autom...

Страница 24: ...conditioner working efficiently you should clean the evaporator filter every week of operation The filter is housed in the intake grill Use a vacuum cleaner to remove dust accumulations from the filter If it is very dirty immerse in warm water and rinse a number of times The water should be luke warm After washing leave the filter to dry then re insert the filter START END OF SEASON OPERATIONS STA...

Страница 25: ...refrigerants safely in accordance with an industry recognized assessment specification WARNING Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer WARNING Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under t...

Страница 26: ... D Decrease the set temperature E Clean the air filter F A mircoprocessor control delays the compressor from operating until 3 mins have passed Noisy or vibration A The surface is not level or not flat enough A Place the unit on a flat level surface if possible Gurgling sound A The sound comes from the flowing of the refrigerant inside the air conditioner A It is normal Unit stops operating A The ...

Страница 27: ...lls to repair or replace the house fuse reset the circuit breaker or correct the wiring in the house REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CUSTOMER BLACK DECKER SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARR...

Страница 28: ... interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televisi...

Страница 29: ...Page 29 ...

Страница 30: ...Page 30 ...

Отзывы: