Page 7
POWER CORD OPERATION
The power supply cord contains a current device that senses damage to the power
cord. To test your supply cord follow these steps:
1. Plug in the Air Conditioner.
2. The power supply cord head has two buttons, a TEST button and a RESET
button. Press the TEST button and notice a click as the RESET button pops out.
3. Press the RESET button. Once again notice a click as the button engages.
4. The power supply cord will now supply electricity to the unit.
NOTE:
• Do not use this device to turn the unit on or
off.
• Always make sure the reset button is pushed
in for correct operation
• The power supply cord must be replaced if
it fails to reset when either the test button is
pushed, or it cannot be reset.
• If power supply cord is damaged, it cannot
be repaired.
• It must be replaced by one obtained from
the product manufacturer.
• After the unit has stopped, the compressor
operate for the first 3 minutes. This is to
protect the unit. Operation will automatically start after 3 minutes.
OPERATING CONDITION
The air conditioner must be operated within the temperature range indicated below:
NOTE:
· Unit performance may be affected when in use outside of these operating temperatures.
RESET
TEST
MODE
ROOM TEMPERATURE
COOL
64˚F (18˚C) ~ 95˚F (35˚C)
DRY
64˚F (18˚C) ~ 95˚F (35°C)
SAFETY INFORMATION
Содержание BPACT12 Series
Страница 23: ...Page 23 ...